Changes for page Shades Integrations
Last modified by Alexander Mott on 2024/06/17 18:07
To version 2.1
edited by Alexander Mott
on 2024/06/14 21:02
on 2024/06/14 21:02
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,123 +1,94 @@ 1 1 (% class="row" %) 2 2 ((( 3 +(% class="box infomessage" %) 4 +((( 5 +Note: page is under construction, check back later for updates 6 +))) 7 + 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. 10 +Controlling shades from ShowRunnerCLC™ is a paid feature that can be purchased either with the initial [[ShowRunnerCLC™ order>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.WebHome]] or added after-the-fact as an additional charge. When shades control or integration is ordered for ShowRunnerCLC™, it is vital to ensure that the BOM includes any required hardware is also ordered. 6 6 12 +While we strive to always provide accurate and complete information, bear in mind that we cannot guarantee that any information provided here will be 100% accurate and up-to-date: always check manufacturer product specifications to verify features and compatibility prior to ordering hardware. 7 7 8 8 = Crestron Shade Controllers = 9 9 10 -(% class="box infomessage" %) 11 -((( 12 -Section is under construction; check again later for updates 13 -))) 16 +Crestron shades are included in all ShowRunnerCLC™ orders, but hardware will not be fully defined in the configuration unless the required information is provided prior to configuration shipment. If the required information cannot be provided with the original order, it is recommended to order [[SR-SDC>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDC.WebHome]] for additional after-order Crestron shades support. 14 14 15 - ==C2N-SDC/C2N-SDC-DC==18 +ShowRunnerCLC™ provides native support for most Crestron shade controllers as well as integration with shades controlled from third-party Crestron processors via Ethernet Inter-Systems Communication (EISC). If integration with a Crestron shades controller or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 16 16 17 -(% class="box infomessage" %) 18 -((( 19 -Section is under construction; check again later for updates 20 -))) 20 +== C2N-SDC(-DC) == 21 21 22 22 == CSA-PWS10S-HUB-ENET == 23 23 24 -(% class="box infomessage" %) 25 -((( 26 -Section is under construction; check again later for updates 27 -))) 28 - 29 29 == DIN-2MC2 == 30 30 31 -(% class="box infomessage" %) 32 -((( 33 -Section is under construction; check again later for updates 34 -))) 35 - 36 36 == Ethernet Inter-Systems Communication (EISC) == 37 37 38 -(% class="box infomessage" %) 39 -((( 40 -Section is under construction; check again later for updates 41 -))) 42 - 43 43 = Third-Party Shade Controllers = 44 44 45 -Lorem 30 +ShowRunnerCLC™ supports integrating with a wide range of common shade control manufacturers, but this integration is not included in basic ShowRunnerCLC™ orders and requires the [[SR-SDN>>doc:showrunner™ Order Guide.showrunner™ Additional Features.Shades.SR-SDN.WebHome]] additional feature. If integration with a shades manufacturer or system that is not detailed below is required, reach out to Chief Integrations directly to see about potentially adding support to ShowRunnerCLC™. 46 46 47 -== Conta ctClosure(Relay)==32 +== Common Integration Methods == 48 48 49 -(% class="box infomessage" %) 50 -((( 51 -Section is under construction; check again later for updates 52 -))) 34 +While most third-party shade controllers have proprietary integration protocols specific to each manufacturer and model, there are common industry standards which dictate the wiring and hardware requirements to integrate third-party shades with ShowRunnerCLC™: 53 53 54 -== Draper IntelliFlex I/O A\V Gateway == 36 +* Contact closure (Relays) 37 +** No standard specified length limitation (individual shade manufacturers may specify cabling and distance limitations) 38 +** Relay control can be susceptible to voltage drop or EMF interference: it is highly recommended to locate the Crestron controlled relay as close as possible to the shades interface being controlled 39 +* Serial RS-232 40 +** 50' maximum distance per specification 41 +** Point-to-point communication mandates a one-to-one relationship of Crestron RS-232 interfaces to shade RS-232 interfaces (i.e. there must be one RS-232 port available on the Crestron system for every RS-232 shade interface; depending on the shades design, a single shades interface may control many shades so it may be possible that a system with many shades only requires one RS-232 connection to the Crestron system) 42 +* Serial RS-485 43 +** 4000' maximum distance per specification (individual shades manufacturers may specify lower cabling and distance limitations, and real-world conditions may reduce the actual maximum distance that can be achieved before system performance is noticeably impacted) 44 +** Multidrop communications allows for daisy-chain and star wiring topologies, up to 32 devices per Crestron RS-485 interface (shades manufacturers may specify lower device counts) 45 +* TCP/IP communication (including HTTP/HTTPS, TelNet, etc.) 46 +** Standard [[Ethernet wiring limitations>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Ethernet Wiring Overview.WebHome]] apply 55 55 56 -(% class="box infomessage" %) 57 -((( 58 -Section is under construction; check again later for updates 59 -))) 48 +Below is a table showing which pieces of Crestron hardware have interfaces for each kind of integration: 60 60 61 -=== IntelliFlex I/O A\V Gateway RS-232 === 50 +|=Hardware|=Relay Outputs|=RS-232 Serial Ports|=RS-485 Serial Ports 51 +|C2N-IO|2|1|✖ 52 +| | | | 53 +| | | | 54 +| | | | 55 +| | | | 56 +|(% colspan="4" %)* Dual-purpose serial ports: each port can be //either// RS-232 //or// RS-485, not both simultaneously 62 62 63 -== =IntelliFlexI/O A\V GatewayRS-485===58 +== Contact Closure (Relays) == 64 64 65 -== LutronSivoiaQS==60 +== Draper IntelliFlex I/O A\V Gateway == 66 66 67 -(% class="box infomessage" %) 68 -((( 69 -Section is under construction; check again later for updates 70 -))) 62 +(% class="wikigeneratedid" %) 63 +RS-232 or RS-485 integration supported 71 71 72 -== =Sivoia QSRS-232===65 +== Lutron Sivoia QS == 73 73 74 -=== Sivoia QS TelNet === 67 +(% class="wikigeneratedid" id="HSivoiaQSRS-232" %) 68 +RS-232 or TelNet integration supported 75 75 76 76 == Lutron Quantum == 77 77 78 -(% class="box infomessage" %) 79 -((( 80 -Section is under construction; check again later for updates 81 -))) 72 +(% class="wikigeneratedid" id="HQuantumRS-232" %) 73 +RS-232 or TelNet integration supported 82 82 83 -=== Quantum RS-232 === 84 - 85 -=== Quantum TelNet === 86 - 87 87 == MechoNet Interface (MNI) == 88 88 89 -(% class="box infomessage" %) 90 -((( 91 -Section is under construction; check again later for updates 92 -))) 77 +(% class="wikigeneratedid" id="HMNIRS-232" %) 78 +Only RS-232 integration supported 93 93 94 -=== MNI RS-232 === 95 - 96 96 == Mecho SolarTrac4 == 97 97 98 -(% class="box infomessage" %) 99 -((( 100 -Section is under construction; check again later for updates 101 -))) 82 +(% class="wikigeneratedid" id="HSolarTrac4BACnet" %) 83 +Only BACnet integration supported 102 102 103 -=== SolarTrac4 BACnet === 104 - 105 105 == Nice DMBM == 106 106 107 -(% class="box infomessage" %) 108 -((( 109 -Section is under construction; check again later for updates 110 -))) 87 +(% class="wikigeneratedid" id="HDMBMRS-232" %) 88 +Only RS-232 integration supported 111 111 112 -=== DMBM RS-232 === 113 - 114 114 == Somfy Digital Network (SDN) == 115 115 116 -(% class="box infomessage" %) 117 -((( 118 -Section is under construction; check again later for updates 119 -))) 120 - 121 121 === SDN RS-485 === 122 122 123 123 === SDN PoE Gateway === ... ... @@ -126,17 +126,11 @@ 126 126 127 127 == Somfy URTSI II == 128 128 129 -(% class="box infomessage" %) 130 -((( 131 -Section is under construction; check again later for updates 100 +(% class="wikigeneratedid" id="HURTSIIIRS-232" %) 101 +RS-232 or RS-485 integration supported 132 132 ))) 133 133 134 -=== URTSI II RS-232 === 135 135 136 -=== URTSI II RS-485 === 137 -))) 138 - 139 - 140 140 (% class="col-xs-12 col-sm-4" %) 141 141 ((( 142 142 {{box title="**CONTENTS**"}}