Version 8.1 by Mark Kohlmann on 2022/09/30 19:41

Show last authors
1 (% class="box warningmessage" %)
2 (((
3 Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.
4 )))
5
6 ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
7
8 * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types
9 * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart
10 * An RSD file will be built for each EISC and a URL will be displayed on the touchscreen to retrieve it
11 * There are 2 EISC modes and only one mode is supported on an EISC definition, multiple EISCs may be defined
12 ** AV Integration
13 *** Provides a standardized interface for controlling areas
14 *** Area selection may be changed at run-time
15 *** [[AV Integration Demo>>url:https://files.chiefintegrations.com/s/Di4aypEKX7APn8n]]
16 *** Signals Provided per Area (signals vary by Area settings/configuration):
17 **** Area Name
18 **** Occupied
19 **** Occupancy Enable/Disable
20 **** Color Temp Auto
21 **** Color Temp Manual Set and Feedback
22 **** Area Master Raise/Lower
23 **** Save Current Scene
24 **** Recall Scene # and Current Scene Feedback
25 **** Extended Scene Export option set
26 ***** Scene Count
27 ***** Scene Names
28 **** Load Count
29 **** Load Level Analogs
30 **** Load Names
31 **** Extended Load Export option set
32 ***** CCT Load type: Color Temp
33 ***** RGB[A|W]: Individual Color Channels
34 **** Shade Count
35 **** All Shade Open/Close
36 **** Shade Name
37 **** Shade Open/Close/Stop
38 **** Ignore Fade Times option set
39 ***** Fade Times are not sent out, only final value.  Reduces traffic.
40 ** Device Export
41 *** Exports devices with specific signals for each device type
42 **** Occupancy Sensor
43 ***** Occupied
44 ***** Online Feedback
45 **** Keyswitch
46 ***** Active Feedback
47 **** Partition Sensor
48 ***** Combined Feedback
49 **** Keypad
50 ***** Enable/Disable w/ Feedback
51 ***** Button Press Event
52 ***** Button Feedback Setting
53 ***** Extended Keypad Export option set
54 ****** Button Tap/Double Tap/Held Events
55 **** Global Actions
56 ***** Activate
57 **** Shade
58 ***** Open/Close/Stop
59 **** Load
60 ***** Level Set and Feedback
61 **** Photocell
62 ***** Sensor Reading
63 **** Area
64 ***** Scene Set and Feedback
65 *** Devices to be exported are defined in the configuration and are not changeable at run-time.
66
67 ==== VC-4 Specific Notes ====
68
69 ===== Prerequisites =====
70
71 * VC-4 server installed
72 * Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]
73 ** [[​​​​​​​>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]Will require SETCSAUTHENTICATION command on processor
74 ** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION
75 * showrunner running on a processor
76 * EISC created in the showrunner config
77 * AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4
78
79 ===== showrunner Config Settings =====
80
81 * Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"##
82 * Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"##
83 * IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead
84
85 ===== Processor Settings =====
86
87 * Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com##
88 * If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password##
89 * Reboot after entering the above settings
90
91 (% class="box warningmessage" %)
92 (((
93 showrunner will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//.  At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types.
94 )))
95
96 (% class="box warningmessage" %)
97 (((