Version 11.1 by Alexander Mott on 2023/05/11 15:56

Show last authors
1 (% class="box warningmessage" %)
2 (((
3 Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.
4 )))
5
6 ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
7
8 * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types
9 * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart
10 * An RSD file will be built for each EISC and a URL will be displayed on the touchscreen to retrieve it
11 * There are 2 EISC modes and only one mode is supported on an EISC definition, multiple EISCs may be defined
12 ** AV Integration
13 *** Provides a standardized interface for controlling areas
14 *** Area selection may be changed at run-time
15 *** [[AV Integration Demo>>url:https://files.chiefintegrations.com/s/Di4aypEKX7APn8n]]
16 *** Signals Provided per Area (signals vary by Area settings/configuration):
17 **** Area Name
18 **** Occupied
19 **** Occupancy Enable/Disable
20 **** Color Temp Auto
21 **** Color Temp Manual Set and Feedback
22 **** Area Master Raise/Lower
23 **** Save Current Scene
24 **** Recall Scene # and Current Scene Feedback
25 **** Extended Scene Export option set
26 ***** Scene Count
27 ***** Scene Names
28 **** Load Count
29 **** Load Level Analogs
30 **** Load Names
31 **** Extended Load Export option set
32 ***** CCT Load type: Color Temp
33 ***** RGB[A|W]: Individual Color Channels
34 **** Shade Count
35 **** All Shade Open/Close
36 **** Shade Name
37 **** Shade Open/Close/Stop
38 **** Ignore Fade Times option set
39 ***** Fade Times are not sent out, only final value.  Reduces traffic.
40 ** Device Export
41 *** Exports devices with specific signals for each device type
42 **** Occupancy Sensor
43 ***** Occupied
44 ***** Online Feedback
45 **** Keyswitch
46 ***** Active Feedback
47 **** Partition Sensor
48 ***** Combined Feedback
49 **** Keypad
50 ***** Enable/Disable w/ Feedback
51 ***** Button Press Event
52 ***** Button Feedback Setting
53 ***** Extended Keypad Export option set
54 ****** Button Tap/Double Tap/Held Events
55 **** Global Actions
56 ***** Activate
57 **** Shade
58 ***** Open/Close/Stop
59 **** Load
60 ***** Level Set and Feedback
61 **** Photocell
62 ***** Sensor Reading
63 **** Area
64 ***** Scene Set and Feedback
65 *** Devices to be exported are defined in the configuration and are not changeable at run-time.
66
67 ==== Processors with Control Subnets ====
68
69 When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It is necessary to either set up CWS users and enable a secure (SCIP on port 41796) EISC or run the following commands:
70
71 * ##securegateway default##
72 ** Enables non-secure connections (CIP on port 41794) from the LAN side
73 * ##isolatenetworks off##
74 ** Enables communications between the LAN and the Control Subnet, where the actual control processor is located
75
76 ==== VC-4 Specific Notes ====
77
78 ===== Prerequisites =====
79
80 * VC-4 server installed
81 * Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]
82 ** Will require SETCSAUTHENTICATION command on processor
83 ** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION
84 * ShowRunnerCLC™ running on a processor
85 * EISC created in the ShowRunnerCLC™ config
86 * AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4
87
88 ===== ShowRunnerCLC™ Config Settings =====
89
90 * Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"##
91 * Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"##
92 * IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead
93
94 ===== Processor Settings =====
95
96 * Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com##
97 * If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password##
98 * Reboot after entering the above settings
99
100 (% class="box warningmessage" %)
101 (((
102 ShowRunnerCLC™ will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//.  At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types.
103 )))
104
105 (% class="box warningmessage" %)
106 (((