Last modified by Mark Kohlmann on 2024/11/19 23:23

From version 9.1
edited by Scott Kohlmann
on 2023/04/20 21:25
Change comment: There is no comment for this version
To version 2.1
edited by Mark Kohlmann
on 2021/06/02 21:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Ethernet Intersystem Communications Export (Crestron)
1 +Ethernet Intersystem Communications (Crestron)
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Integrations Guide.Integration Options.WebHome
1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.scott\.kohlmann@chiefintegrations\.com
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Content
... ... @@ -1,10 +1,5 @@
1 -(% class="box warningmessage" %)
2 -(((
3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.
4 -)))
1 +ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
5 5  
6 -ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
7 -
8 8  * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types
9 9  * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart
10 10  * An RSD file will be built for each EISC and a URL will be displayed on the touchscreen to retrieve it
... ... @@ -13,87 +13,7 @@
13 13  *** Provides a standardized interface for controlling areas
14 14  *** Area selection may be changed at run-time
15 15  *** [[AV Integration Demo>>url:https://files.chiefintegrations.com/s/Di4aypEKX7APn8n]]
16 -*** Signals Provided per Area (signals vary by Area settings/configuration):
17 -**** Area Name
18 -**** Occupied
19 -**** Occupancy Enable/Disable
20 -**** Color Temp Auto
21 -**** Color Temp Manual Set and Feedback
22 -**** Area Master Raise/Lower
23 -**** Save Current Scene
24 -**** Recall Scene # and Current Scene Feedback
25 -**** Extended Scene Export option set
26 -***** Scene Count
27 -***** Scene Names
28 -**** Load Count
29 -**** Load Level Analogs
30 -**** Load Names
31 -**** Extended Load Export option set
32 -***** CCT Load type: Color Temp
33 -***** RGB[A|W]: Individual Color Channels
34 -**** Shade Count
35 -**** All Shade Open/Close
36 -**** Shade Name
37 -**** Shade Open/Close/Stop
38 -**** Ignore Fade Times option set
39 -***** Fade Times are not sent out, only final value.  Reduces traffic.
40 40  ** Device Export
41 -*** Exports devices with specific signals for each device type
42 -**** Occupancy Sensor
43 -***** Occupied
44 -***** Online Feedback
45 -**** Keyswitch
46 -***** Active Feedback
47 -**** Partition Sensor
48 -***** Combined Feedback
49 -**** Keypad
50 -***** Enable/Disable w/ Feedback
51 -***** Button Press Event
52 -***** Button Feedback Setting
53 -***** Extended Keypad Export option set
54 -****** Button Tap/Double Tap/Held Events
55 -**** Global Actions
56 -***** Activate
57 -**** Shade
58 -***** Open/Close/Stop
59 -**** Load
60 -***** Level Set and Feedback
61 -**** Photocell
62 -***** Sensor Reading
63 -**** Area
64 -***** Scene Set and Feedback
65 -*** Devices to be exported are defined in the configuration and are not changeable at run-time.
66 -
67 -==== VC-4 Specific Notes ====
68 -
69 -===== Prerequisites =====
70 -
71 -* VC-4 server installed
72 -* Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]
73 -** Will require SETCSAUTHENTICATION command on processor
74 -** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION
75 -* ShowRunnerCLC™ running on a processor
76 -* EISC created in the ShowRunnerCLC™ config
77 -* AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4
78 -
79 -===== ShowRunnerCLC™ Config Settings =====
80 -
81 -* Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"##
82 -* Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"##
83 -* IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead
84 -
85 -===== Processor Settings =====
86 -
87 -* Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com##
88 -* If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password##
89 -* Reboot after entering the above settings
90 -
91 -(% class="box warningmessage" %)
92 -(((
93 -ShowRunnerCLC™ will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//.  At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types.
94 -)))
95 -
96 -(% class="box warningmessage" %)
97 -(((
98 -ShowRunnerCLC™ uses analog join 4001 on normal EISCs to confirm the logic is fully online.  Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead.
99 -)))
12 +*** Exports devices with specific parameters for each device type
13 +*** Devices to be exported are defined in the configuration and are not changeable at run-time
14 +* Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.