Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. scott\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,6 +1,11 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. 3 +Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. When importing a new or updated RSD file to the A/V program, ensure the appropriate options are selected: 4 + 5 +* "Disconnect signal from Etherenet ISC symbol in program." 6 +* "Change Locally: Update signal name in EISC ISC symbol only." 7 + 8 +[[image:MicrosoftTeams-image.png||height="413" width="394"]] 4 4 ))) 5 5 6 6 ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. ... ... @@ -64,6 +64,15 @@ 64 64 ***** Scene Set and Feedback 65 65 *** Devices to be exported are defined in the configuration and are not changeable at run-time. 66 66 72 +==== Processors with Control Subnets ==== 73 + 74 +When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It is necessary to either set up CWS users and enable a secure (SCIP on port 41796) EISC or run the following commands: 75 + 76 +* ##securegateway default## 77 +** Enables non-secure connections (CIP on port 41794) from the LAN side 78 +* ##isolatenetworks off## 79 +** Enables communications between the LAN and the Control Subnet, where the actual control processor is located 80 + 67 67 ==== VC-4 Specific Notes ==== 68 68 69 69 ===== Prerequisites =====
- MicrosoftTeams-image.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +186.5 KB - Content