... ... @@ -64,6 +64,15 @@
64 64  ***** Scene Set and Feedback
65 65  *** Devices to be exported are defined in the configuration and are not changeable at run-time.
66 66  
67 +==== Processors with Control Subnets ====
68 +
69 +When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It is necessary to either set up CWS users and enable a secure (SCIP on port 41796) EISC or run the following commands:
70 +
71 +* ##securegateway default##
72 +** Enables non-secure connections (CIP on port 41794) from the LAN side
73 +* ##isolatenetworks off##
74 +** Enables communications between the LAN and the Control Subnet, where the actual control processor is located
75 +