... ... @@ -64,6 +64,16 @@
64 64  ***** Scene Set and Feedback
65 65  *** Devices to be exported are defined in the configuration and are not changeable at run-time.
66 66  
67 +(% class="wikigeneratedid" %)
68 +==== Processors with Control Subnets ====
69 +
70 +When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. These commands are the same for both 3-Series and 4-Series processors:
71 +
72 +* ##securegateway default##
73 +** Enables non-secure connections (CIP on port 41794) from the LAN side instead of requiring a secure connection (SCIP on port 41796)
74 +* ##isolatenetworks off##
75 +** Enables communications between the LAN and the Control Subnet, where the actual control processor is located
76 +