Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 8.1
edited by Mark Kohlmann
on 2022/09/30 19:41
on 2022/09/30 19:41
Change comment:
There is no comment for this version
To version 7.1
edited by Mark Kohlmann
on 2021/12/22 21:36
on 2021/12/22 21:36
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -63,37 +63,3 @@ 63 63 **** Area 64 64 ***** Scene Set and Feedback 65 65 *** Devices to be exported are defined in the configuration and are not changeable at run-time. 66 - 67 -==== VC-4 Specific Notes ==== 68 - 69 -===== Prerequisites ===== 70 - 71 -* VC-4 server installed 72 -* Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]] 73 -** [[>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]Will require SETCSAUTHENTICATION command on processor 74 -** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION 75 -* showrunner running on a processor 76 -* EISC created in the showrunner config 77 -* AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4 78 - 79 -===== showrunner Config Settings ===== 80 - 81 -* Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"## 82 -* Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"## 83 -* IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead 84 - 85 -===== Processor Settings ===== 86 - 87 -* Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com## 88 -* If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password## 89 -* Reboot after entering the above settings 90 - 91 -(% class="box warningmessage" %) 92 -((( 93 -showrunner will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//. At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types. 94 -))) 95 - 96 -(% class="box warningmessage" %) 97 -((( 98 -showrunner uses analog join 4001 on normal EISCs to confirm the logic is fully online. Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead. 99 -)))