Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 7.1
edited by Mark Kohlmann
on 2021/12/22 21:36
on 2021/12/22 21:36
Change comment:
There is no comment for this version
To version 1.1
edited by Mark Kohlmann
on 2021/06/02 21:46
on 2021/06/02 21:46
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Ethernet Intersystem Communications Export(Crestron)1 +Ethernet Intersystem Communications (Crestron) - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Content
-
... ... @@ -1,8 +6,3 @@ 1 -(% class="box warningmessage" %) 2 -((( 3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. 4 -))) 5 - 6 6 ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. 7 7 8 8 * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types ... ... @@ -11,55 +11,8 @@ 11 11 * There are 2 EISC modes and only one mode is supported on an EISC definition, multiple EISCs may be defined 12 12 ** AV Integration 13 13 *** Provides a standardized interface for controlling areas 14 -*** Area selection may be changed at run-time 15 -*** [[AV Integration Demo>>url:https://files.chiefintegrations.com/s/Di4aypEKX7APn8n]] 16 -*** Signals Provided per Area (signals vary by Area settings/configuration): 17 -**** Area Name 18 -**** Occupied 19 -**** Occupancy Enable/Disable 20 -**** Color Temp Auto 21 -**** Color Temp Manual Set and Feedback 22 -**** Area Master Raise/Lower 23 -**** Save Current Scene 24 -**** Recall Scene # and Current Scene Feedback 25 -**** Extended Scene Export option set 26 -***** Scene Count 27 -***** Scene Names 28 -**** Load Count 29 -**** Load Level Analogs 30 -**** Load Names 31 -**** Extended Load Export option set 32 -***** CCT Load type: Color Temp 33 -***** RGB[A|W]: Individual Color Channels 34 -**** Shade Count 35 -**** All Shade Open/Close 36 -**** Shade Name 37 -**** Shade Open/Close/Stop 38 -**** Ignore Fade Times option set 39 -***** Fade Times are not sent out, only final value. Reduces traffic. 9 +*** Areas may be selected at run-time 10 +*** 40 40 ** Device Export 41 -*** Exports devices with specific signals for each device type 42 -**** Occupancy Sensor 43 -***** Occupied 44 -***** Online Feedback 45 -**** Keyswitch 46 -***** Active Feedback 47 -**** Partition Sensor 48 -***** Combined Feedback 49 -**** Keypad 50 -***** Enable/Disable w/ Feedback 51 -***** Button Press Event 52 -***** Button Feedback Setting 53 -***** Extended Keypad Export option set 54 -****** Button Tap/Double Tap/Held Events 55 -**** Global Actions 56 -***** Activate 57 -**** Shade 58 -***** Open/Close/Stop 59 -**** Load 60 -***** Level Set and Feedback 61 -**** Photocell 62 -***** Sensor Reading 63 -**** Area 64 -***** Scene Set and Feedback 65 -*** Devices to be exported are defined in the configuration and are not changeable at run-time. 12 +*** Exports devices with specific parameters for each device type 13 +*** Devices to be exported are defined in the configuration