Last modified by Mark Kohlmann on 2024/11/19 23:23

From version 6.2
edited by Mark Kohlmann
on 2021/12/08 21:05
Change comment: Update document after refactoring.
To version 2.1
edited by Mark Kohlmann
on 2021/06/02 21:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Integrations Guide.Integration Options.WebHome
1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome
Content
... ... @@ -1,8 +6,3 @@
1 -(% class="box warningmessage" %)
2 -(((
3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.
4 -)))
5 -
6 6  ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
7 7  
8 8  * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types
... ... @@ -13,53 +13,7 @@
13 13  *** Provides a standardized interface for controlling areas
14 14  *** Area selection may be changed at run-time
15 15  *** [[AV Integration Demo>>url:https://files.chiefintegrations.com/s/Di4aypEKX7APn8n]]
16 -*** Signals Provided per Area (signals vary by Area settings/configuration):
17 -**** Area Name
18 -**** Occupied
19 -**** Occupancy Enable/Disable
20 -**** Color Temp Auto
21 -**** Color Temp Manual Set and Feedback
22 -**** Area Master Raise/Lower
23 -**** Save Current Scene
24 -**** Recall Scene # and Current Scene Feedback
25 -**** Extended Scene Export option set
26 -***** Scene Count
27 -***** Scene Names
28 -**** Load Count
29 -**** Load Level Analogs
30 -**** Load Names
31 -**** Extended Load Export option set
32 -***** CCT Load type: Color Temp
33 -***** RGB[A|W]: Individual Color Channels
34 -**** Shade Count
35 -**** All Shade Open/Close
36 -**** Shade Name
37 -**** Shade Open/Close/Stop
38 -**** Ignore Fade Times option set
39 -***** Fade Times are not sent out, only final value.  Reduces traffic.
40 40  ** Device Export
41 -*** Exports devices with specific signals for each device type
42 -**** Occupancy Sensor
43 -***** Occupied
44 -***** Online Feedback
45 -**** Keyswitch
46 -***** Active Feedback
47 -**** Partition Sensor
48 -***** Combined Feedback
49 -**** Keypad
50 -***** Enable/Disable w/ Feedback
51 -***** Button Press Event
52 -***** Button Feedback Setting
53 -***** Extended Keypad Export option set
54 -****** Button Tap/Double Tap/Held Events
55 -**** Global Actions
56 -***** Activate
57 -**** Shade
58 -***** Open/Close/Stop
59 -**** Load
60 -***** Level Set and Feedback
61 -**** Photocell
62 -***** Sensor Reading
63 -**** Area
64 -***** Scene Set and Feedback
65 -*** Devices to be exported are defined in the configuration and are not changeable at run-time.
12 +*** Exports devices with specific parameters for each device type
13 +*** Devices to be exported are defined in the configuration and are not changeable at run-time
14 +* Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.