Last modified by Mark Kohlmann on 2024/11/19 23:23

From version 4.1
edited by Mark Kohlmann
on 2021/06/02 22:07
Change comment: There is no comment for this version
To version 9.1
edited by Scott Kohlmann
on 2023/04/20 21:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Ethernet Intersystem Communications (Crestron)
1 +Ethernet Intersystem Communications Export (Crestron)
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome
1 +SHOWRUNNER™ Integrations Guide.Integration Options.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.mark\.kohlmann@chiefintegrations\.com
1 +XWiki.scott\.kohlmann@chiefintegrations\.com
Content
... ... @@ -1,5 +1,10 @@
1 -ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
1 +(% class="box warningmessage" %)
2 +(((
3 +Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.
4 +)))
2 2  
6 +ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
7 +
3 3  * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types
4 4  * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart
5 5  * An RSD file will be built for each EISC and a URL will be displayed on the touchscreen to retrieve it
... ... @@ -30,7 +30,8 @@
30 30  **** All Shade Open/Close
31 31  **** Shade Name
32 32  **** Shade Open/Close/Stop
33 -****
38 +**** Ignore Fade Times option set
39 +***** Fade Times are not sent out, only final value.  Reduces traffic.
34 34  ** Device Export
35 35  *** Exports devices with specific signals for each device type
36 36  **** Occupancy Sensor
... ... @@ -56,9 +56,38 @@
56 56  ***** Sensor Reading
57 57  **** Area
58 58  ***** Scene Set and Feedback
59 -*** Devices to be exported are defined in the configuration and are not changeable at run-tim
65 +*** Devices to be exported are defined in the configuration and are not changeable at run-time.
60 60  
67 +==== VC-4 Specific Notes ====
68 +
69 +===== Prerequisites =====
70 +
71 +* VC-4 server installed
72 +* Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]
73 +** Will require SETCSAUTHENTICATION command on processor
74 +** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION
75 +* ShowRunnerCLC™ running on a processor
76 +* EISC created in the ShowRunnerCLC™ config
77 +* AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4
78 +
79 +===== ShowRunnerCLC™ Config Settings =====
80 +
81 +* Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"##
82 +* Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"##
83 +* IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead
84 +
85 +===== Processor Settings =====
86 +
87 +* Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com##
88 +* If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password##
89 +* Reboot after entering the above settings
90 +
61 61  (% class="box warningmessage" %)
62 62  (((
63 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.
93 +ShowRunnerCLC™ will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//.  At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types.
64 64  )))
95 +
96 +(% class="box warningmessage" %)
97 +(((
98 +ShowRunnerCLC™ uses analog join 4001 on normal EISCs to confirm the logic is fully online.  Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead.
99 +)))