Last modified by Mark Kohlmann on 2024/11/19 23:23

From version 19.1
edited by Alexander Mott
on 2023/12/15 20:24
Change comment: There is no comment for this version
To version 20.1
edited by Mark Kohlmann
on 2024/08/01 17:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
1 +XWiki.mark\.kohlmann@chiefintegrations\.com
Content
... ... @@ -5,7 +5,7 @@
5 5  * "Disconnect signal from Etherenet ISC symbol in program."
6 6  * "Change Locally: Update signal name in EISC ISC symbol only."
7 7  
8 -[[image:MicrosoftTeams-image.png||height="413" width="394"]]
8 +[[image:MicrosoftTeams-image.png||queryString="width=394&height=413" height="413" width="394"]]
9 9  )))
10 10  
11 11  ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.
... ... @@ -132,13 +132,13 @@
132 132  ===== ShowRunnerCLC™ Config Settings (Importing from a third-party VC-4, ShowRunnerCLC™ on Processor) =====
133 133  
134 134  * Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"##
135 -* Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"##
135 +* Define Vc4RoomId in config: ##"Vc4RoomId": "**VC4ROOMID**"##
136 136  * IpAddressOrHostname will not be used, instead VCSERVERADDR console command will be used instead
137 137  
138 138  ===== Processor Settings =====
139 139  
140 -* Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com##
141 -* If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password##
140 +* Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR **my-vc-4-server.mycorpnet.com**##
141 +* If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:**vc4user** -p:**vc4password**##
142 142  * Reboot after entering the above settings
143 143  
144 144  (% class="box warningmessage" %)
... ... @@ -148,5 +148,69 @@
148 148  
149 149  (% class="box warningmessage" %)
150 150  (((
151 -ShowRunnerCLC™ uses analog join 4001 on normal EISCs to confirm the logic is fully online.  Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead.
151 +ShowRunnerCLC™ uses analog join 4001 on normal EISCs to confirm the logic is fully online.  Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead.
152 152  )))
153 +
154 +(% class="box errormessage" %)
155 +(((
156 +Crestron Processors cannot use the VirtualControlEiscClient to multiple different VC-4 instances, firmware limitation of VCSERVERADDR command
157 +)))
158 +
159 +(% class="box errormessage" %)
160 +(((
161 +Crestron Processors cannot use multiple Control System Authentication (setcsauthentication) settings, firmware limitation of SETCSAUTHENTICATION command
162 +)))
163 +
164 +==== EISC Settings by Topology ====
165 +
166 +The following table defines the EISC types to use between ShowRunnerCLC™ and an AV program when they are connecting to each other.
167 +
168 +IP Address Requirements:
169 +//EISC Packed// and //3-Series TCP/IP EISC// need both processors to know each other's IP Address.
170 +//EISC Server// accepts EISC connections from an //EISC Client// or a //VC-4 EISC Client.//  Only the EISC Client side must know the IP address of the EISC Server.
171 +
172 +|=EISC Created By|=ShowRunner Host Type|=ShowRunner EISC Type|=AV Processor Host Type|=AV EISC Type
173 +|ShowRunner|Processor|(((
174 +EiscPacked* ~*~*~*~*
175 +
176 +ThreeSeriesEisc*
177 +
178 +EiscServer
179 +)))|Processor|(((
180 +SR Setting //EiscPacked//:
181 +Ethernet Intersystem Communications* ~*~*~*~*
182 +Ethernet Intersystem Communications (Packed)* ~*~*~*~*
183 +\\SR Setting //ThreeSeriesEisc//:
184 +3-Series TCP/IP Ethernet Intersystem Communications*
185 +
186 +SR Settings //EiscServer//:
187 +EISC Client*
188 +)))
189 +|ShowRunner|Processor|EiscServer|VC-4 Room|EISC Client*
190 +|ShowRunner|VC-4 Room|EiscServer|Processor|VC-4 EISC Client* ~*~*
191 +|ShowRunner|VC-4 Room|EiscServer|VC-4 Room|VC-4 EISC Client* ~*~*
192 +|AV Program|Processor|(((
193 +EiscPacked* ~*~*~*~*
194 +
195 +ThreeSeriesEisc*
196 +
197 +EiscServer
198 +)))|Processor|(((
199 +SR Setting //EiscPacked//:
200 +Ethernet Intersystem Communications* ~*~*~*~*
201 +Ethernet Intersystem Communications (Packed)* ~*~*~*~*
202 +\\SR Setting //ThreeSeriesEisc//:
203 +3-Series TCP/IP Ethernet Intersystem Communications*
204 +
205 +SR Settings //EiscServer//:
206 +EISC Client*
207 +)))
208 +|AV Program|Processor|VirtualControlEiscClient* ~*~**|VC-4 Room|EiscServer
209 +|AV Program|VC-4 Room|EiscClient*|Processor|EiscServer
210 +|AV Program|VC-4 Room|VirtualControlEiscClient* ~*~**|VC-4 Room|EiscServer
211 +
212 +Notes:
213 +~* Must configure IP Address of Remote Processor
214 +~** Must configure VC-4 RoomID for connection in symbol definition
215 +~*~*~* Must configure "Vc4RoomId" property in SR Config set to the ROOMID of the remote VC-4 instance
216 +~*~*~** 2-Series processor compatible