Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 18.1
edited by Austin Weygandt
on 2023/11/16 17:22
on 2023/11/16 17:22
Change comment:
There is no comment for this version
To version 8.1
edited by Mark Kohlmann
on 2022/09/30 19:41
on 2022/09/30 19:41
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a ustin\.weygandt@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,14 +1,9 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. When importing a new or updated RSD file to the A/V program, ensure the appropriate options are selected: 4 - 5 -* "Disconnect signal from Etherenet ISC symbol in program." 6 -* "Change Locally: Update signal name in EISC ISC symbol only." 7 - 8 -[[image:MicrosoftTeams-image.png||height="413" width="394"]] 3 +Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. 9 9 ))) 10 10 11 -ShowRunner CLC™provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.6 +ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. 12 12 13 13 * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types 14 14 * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart ... ... @@ -69,44 +69,6 @@ 69 69 ***** Scene Set and Feedback 70 70 *** Devices to be exported are defined in the configuration and are not changeable at run-time. 71 71 72 -==== Creating Remote Connections through the UI ==== 73 - 74 -* Open the Setting (Gear icon in upper right corner) screen from the main page 75 -* Select Crestron Integration 76 -* To add and edit a new connection: 77 -** press the + Add at the bottom left corner of the page 78 -** In the left column select the connection you want to edit 79 -** In the middle column enter: 80 -*** Connection label 81 -*** IP Address of the AV Processor 82 -*** IP ID 83 -** Additional features can be selected: 84 -*** Ignore Fade Times 85 -*** Extended Load Export 86 -*** Extended Scene Export 87 -** EISC Type: 88 -*** Classic (2-Series Compatible) 89 -*** 3-series TCP EISC 90 -** In the right column select all areas needed 91 -** Save by clicking on the Check mark that appears to the right or "Settings:" in the middle column 92 -** Saving will generate an RSD File URL at the bottom of the middle column 93 -*** http:~/~/10.0.0.10/ShowRunner/RSDs/IP-ID0xF1Lighting_Interface.rsd 94 -*** 10.0.0.10 = Lighting system Processor IP Address 95 -*** IP-ID0xF1 = Lighting system Processor IP Table entry for AV integration 96 -** RSD file can also be retrieved from the Toolbox File Manager app 97 -*** Open File Manager 98 -*** Select Internal Flash/HTML/ShowRunner/RSDs 99 -*** all generated RSD files will be available in this folder 100 - 101 -==== Processors with Control Subnets ==== 102 - 103 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It is necessary to either set up CWS users and enable a secure (SCIP on port 41796) EISC or run the following commands: 104 - 105 -* ##securegateway default## 106 -** Enables non-secure connections (CIP on port 41794) from the LAN side 107 -* ##isolatenetworks off## 108 -** Enables communications between the LAN and the Control Subnet, where the actual control processor is located 109 - 110 110 ==== VC-4 Specific Notes ==== 111 111 112 112 ===== Prerequisites ===== ... ... @@ -113,23 +113,17 @@ 113 113 114 114 * VC-4 server installed 115 115 * Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]] 116 -** Will require SETCSAUTHENTICATION command on processor 73 +** [[>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]Will require SETCSAUTHENTICATION command on processor 117 117 ** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION 118 -* ShowRunnerCLC™running on a processor119 -* EISC created in the ShowRunnerCLC™config75 +* showrunner running on a processor 76 +* EISC created in the showrunner config 120 120 * AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4 121 121 122 -===== ShowRunnerCLC™Config Settings(Exporting from a ShowRunnerCLC™ VC-4)=====79 +===== showrunner Config Settings ===== 123 123 124 -* Define EiscType in config: ##"EiscType": "EiscServer"## 125 -* Everything else defined as normal 126 -* RSD file will be available in "/opt/crestron/virtualcontrol/RunningPrograms/**[ROOMID]**/Html/ShowRunner/RSDs/" 127 - 128 -===== ShowRunnerCLC™ Config Settings (Importing from a third-party VC-4, ShowRunnerCLC™ on Processor) ===== 129 - 130 130 * Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"## 131 131 * Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"## 132 -* IpAddressOrHostname will not beused, instead VCSERVERADDRconsole commandwill be used instead83 +* IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead 133 133 134 134 ===== Processor Settings ===== 135 135 ... ... @@ -139,10 +139,10 @@ 139 139 140 140 (% class="box warningmessage" %) 141 141 ((( 142 - ShowRunnerCLC™will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//. At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types.93 +showrunner will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//. At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types. 143 143 ))) 144 144 145 145 (% class="box warningmessage" %) 146 146 ((( 147 - ShowRunnerCLC™uses analog join 4001 on normal EISCs to confirm the logic is fully online. Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead.98 +showrunner uses analog join 4001 on normal EISCs to confirm the logic is fully online. Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead. 148 148 )))
- MicrosoftTeams-image.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -186.5 KB - Content