Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 17.1
edited by Alexander Mott
on 2023/10/02 15:26
on 2023/10/02 15:26
Change comment:
There is no comment for this version
To version 2.1
edited by Mark Kohlmann
on 2021/06/02 21:49
on 2021/06/02 21:49
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Ethernet Intersystem Communications Export(Crestron)1 +Ethernet Intersystem Communications (Crestron) - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,15 +1,5 @@ 1 -(% class="box warningmessage" %) 2 -((( 3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. When importing a new or updated RSD file to the A/V program, ensure the appropriate options are selected: 1 +ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. 4 4 5 -* "Disconnect signal from Etherenet ISC symbol in program." 6 -* "Change Locally: Update signal name in EISC ISC symbol only." 7 - 8 -[[image:MicrosoftTeams-image.png||height="413" width="394"]] 9 -))) 10 - 11 -ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. 12 - 13 13 * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types 14 14 * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart 15 15 * An RSD file will be built for each EISC and a URL will be displayed on the touchscreen to retrieve it ... ... @@ -18,131 +18,7 @@ 18 18 *** Provides a standardized interface for controlling areas 19 19 *** Area selection may be changed at run-time 20 20 *** [[AV Integration Demo>>url:https://files.chiefintegrations.com/s/Di4aypEKX7APn8n]] 21 -*** Signals Provided per Area (signals vary by Area settings/configuration): 22 -**** Area Name 23 -**** Occupied 24 -**** Occupancy Enable/Disable 25 -**** Color Temp Auto 26 -**** Color Temp Manual Set and Feedback 27 -**** Area Master Raise/Lower 28 -**** Save Current Scene 29 -**** Recall Scene # and Current Scene Feedback 30 -**** Extended Scene Export option set 31 -***** Scene Count 32 -***** Scene Names 33 -**** Load Count 34 -**** Load Level Analogs 35 -**** Load Names 36 -**** Extended Load Export option set 37 -***** CCT Load type: Color Temp 38 -***** RGB[A|W]: Individual Color Channels 39 -**** Shade Count 40 -**** All Shade Open/Close 41 -**** Shade Name 42 -**** Shade Open/Close/Stop 43 -**** Ignore Fade Times option set 44 -***** Fade Times are not sent out, only final value. Reduces traffic. 45 45 ** Device Export 46 -*** Exports devices with specific signals for each device type 47 -**** Occupancy Sensor 48 -***** Occupied 49 -***** Online Feedback 50 -**** Keyswitch 51 -***** Active Feedback 52 -**** Partition Sensor 53 -***** Combined Feedback 54 -**** Keypad 55 -***** Enable/Disable w/ Feedback 56 -***** Button Press Event 57 -***** Button Feedback Setting 58 -***** Extended Keypad Export option set 59 -****** Button Tap/Double Tap/Held Events 60 -**** Global Actions 61 -***** Activate 62 -**** Shade 63 -***** Open/Close/Stop 64 -**** Load 65 -***** Level Set and Feedback 66 -**** Photocell 67 -***** Sensor Reading 68 -**** Area 69 -***** Scene Set and Feedback 70 -*** Devices to be exported are defined in the configuration and are not changeable at run-time. 71 - 72 -==== Creating Remote Connections through the UI ==== 73 - 74 -* Open the Setting (Gear icon in upper right corner) screen from the main page 75 -* Select Crestron Integration 76 -* To add and edit a new connection: 77 -** press the + Add at the bottom left corner of the page 78 -** In the left column select the connection you want to edit 79 -** In the middle column enter: 80 -*** Connection label 81 -*** IP Address of the AV Processor 82 -*** IP ID 83 -** Additional features can be selected: 84 -*** Ignore Fade Times 85 -*** Extended Load Export 86 -*** Extended Scene Export 87 -** EISC Type: 88 -*** Classic (2-Series Compatible) 89 -*** 3-series TCP EISC 90 -** In the right column select all areas needed 91 -** Save by clicking on the Check mark that appears to the right or "Settings:" in the middle column 92 -** Saving will generate an RSD File URL at the bottom of the middle column 93 -*** http:~/~/10.0.0.10/ShowRunner/RSDs/IP-ID0xF1Lighting_Interface.rsd 94 -*** 10.0.0.10 = Lighting system Processor IP Address 95 -*** IP-ID0xF1 = Lighting system Processor IP Table entry for AV integration 96 -** RSD file can also be retrieved from the Toolbox File Manager app 97 -*** Open File Manager 98 -*** Select Internal Flash/HTML/ShowRunner/RSDs 99 -*** all generated RSD files will be available in this folder 100 - 101 -==== Processors with Control Subnets ==== 102 - 103 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It is necessary to either set up CWS users and enable a secure (SCIP on port 41796) EISC or run the following commands: 104 - 105 -* ##securegateway default## 106 -** Enables non-secure connections (CIP on port 41794) from the LAN side 107 -* ##isolatenetworks off## 108 -** Enables communications between the LAN and the Control Subnet, where the actual control processor is located 109 - 110 -==== VC-4 Specific Notes ==== 111 - 112 -===== Prerequisites ===== 113 - 114 -* VC-4 server installed 115 -* Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]] 116 -** Will require SETCSAUTHENTICATION command on processor 117 -** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION 118 -* ShowRunnerCLC™ running on a processor 119 -* EISC created in the ShowRunnerCLC™ config 120 -* AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4 121 - 122 -===== ShowRunnerCLC™ Config Settings (Exporting from a ShowRunnerCLC™ VC-4) ===== 123 - 124 -* Define EiscType in config: ##"EiscType": "EiscServer"## 125 -* Everything else defined as normal 126 -* RSD file will be available in "/opt/crestron/virtualcontrol/RunningPrograms/**[ROOMID]**/Html/ShowRunner/RSDs/" 127 - 128 -===== ShowRunnerCLC™ Config Settings (Importing from a third-party VC-4) ===== 129 - 130 -* Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"## 131 -* Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"## 132 -* IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead 133 - 134 -===== Processor Settings ===== 135 - 136 -* Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com## 137 -* If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password## 138 -* Reboot after entering the above settings 139 - 140 -(% class="box warningmessage" %) 141 -((( 142 -ShowRunnerCLC™ will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//. At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types. 143 -))) 144 - 145 -(% class="box warningmessage" %) 146 -((( 147 -ShowRunnerCLC™ uses analog join 4001 on normal EISCs to confirm the logic is fully online. Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead. 148 -))) 12 +*** Exports devices with specific parameters for each device type 13 +*** Devices to be exported are defined in the configuration and are not changeable at run-time 14 +* Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes.
- MicrosoftTeams-image.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -186.5 KB - Content