Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 17.1
edited by Alexander Mott
on 2023/10/02 15:26
on 2023/10/02 15:26
Change comment:
There is no comment for this version
To version 10.1
edited by Alexander Mott
on 2023/05/11 15:30
on 2023/05/11 15:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,6 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. When importing a new or updated RSD file to the A/V program, ensure the appropriate options are selected: 4 - 5 -* "Disconnect signal from Etherenet ISC symbol in program." 6 -* "Change Locally: Update signal name in EISC ISC symbol only." 7 - 8 -[[image:MicrosoftTeams-image.png||height="413" width="394"]] 3 +Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. 9 9 ))) 10 10 11 11 ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. ... ... @@ -69,41 +69,13 @@ 69 69 ***** Scene Set and Feedback 70 70 *** Devices to be exported are defined in the configuration and are not changeable at run-time. 71 71 72 -==== Creating Remote Connections through the UI ==== 73 - 74 -* Open the Setting (Gear icon in upper right corner) screen from the main page 75 -* Select Crestron Integration 76 -* To add and edit a new connection: 77 -** press the + Add at the bottom left corner of the page 78 -** In the left column select the connection you want to edit 79 -** In the middle column enter: 80 -*** Connection label 81 -*** IP Address of the AV Processor 82 -*** IP ID 83 -** Additional features can be selected: 84 -*** Ignore Fade Times 85 -*** Extended Load Export 86 -*** Extended Scene Export 87 -** EISC Type: 88 -*** Classic (2-Series Compatible) 89 -*** 3-series TCP EISC 90 -** In the right column select all areas needed 91 -** Save by clicking on the Check mark that appears to the right or "Settings:" in the middle column 92 -** Saving will generate an RSD File URL at the bottom of the middle column 93 -*** http:~/~/10.0.0.10/ShowRunner/RSDs/IP-ID0xF1Lighting_Interface.rsd 94 -*** 10.0.0.10 = Lighting system Processor IP Address 95 -*** IP-ID0xF1 = Lighting system Processor IP Table entry for AV integration 96 -** RSD file can also be retrieved from the Toolbox File Manager app 97 -*** Open File Manager 98 -*** Select Internal Flash/HTML/ShowRunner/RSDs 99 -*** all generated RSD files will be available in this folder 100 - 67 +(% class="wikigeneratedid" %) 101 101 ==== Processors with Control Subnets ==== 102 102 103 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It isnecessaryto eithersetupCWSusers and enable a secure(SCIP onport 41796) EISCor run thefollowing commands:70 +When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. These commands are the same for both 3-Series and 4-Series processors: 104 104 105 105 * ##securegateway default## 106 -** Enables non-secure connections (CIP on port 41794) from the LAN side 73 +** Enables non-secure connections (CIP on port 41794) from the LAN side instead of requiring a secure connection (SCIP on port 41796) 107 107 * ##isolatenetworks off## 108 108 ** Enables communications between the LAN and the Control Subnet, where the actual control processor is located 109 109 ... ... @@ -119,14 +119,8 @@ 119 119 * EISC created in the ShowRunnerCLC™ config 120 120 * AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4 121 121 122 -===== ShowRunnerCLC™ Config Settings (Exporting from a ShowRunnerCLC™ VC-4)=====89 +===== ShowRunnerCLC™ Config Settings ===== 123 123 124 -* Define EiscType in config: ##"EiscType": "EiscServer"## 125 -* Everything else defined as normal 126 -* RSD file will be available in "/opt/crestron/virtualcontrol/RunningPrograms/**[ROOMID]**/Html/ShowRunner/RSDs/" 127 - 128 -===== ShowRunnerCLC™ Config Settings (Importing from a third-party VC-4) ===== 129 - 130 130 * Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"## 131 131 * Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"## 132 132 * IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead
- MicrosoftTeams-image.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -186.5 KB - Content