Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 15.1
edited by Mark Kohlmann
on 2023/08/30 19:05
on 2023/08/30 19:05
Change comment:
There is no comment for this version
To version 19.1
edited by Alexander Mott
on 2023/12/15 20:24
on 2023/12/15 20:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -119,11 +119,21 @@ 119 119 * EISC created in the ShowRunnerCLC™ config 120 120 * AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4 121 121 122 -===== ShowRunnerCLC™ Config Settings ===== 122 +===== ShowRunnerCLC™ Config Settings (Exporting from a ShowRunnerCLC™ VC-4) ===== 123 123 124 +* Define EiscType in config: ##"EiscType": "EiscServer"## 125 +* Everything else defined as normal 126 +* RSD file will be available in "/opt/crestron/virtualcontrol/RunningPrograms/**[ROOMID]**/Html/ShowRunner/RSDs/" 127 +* When importing the RSD to the AV program, the following steps need to be taken: 128 +** In the configuration tab, right-click the imported EISC and select "Replace" 129 +** Replace the imported RSD with a "VC-4 EISC Client" 130 +** In the device settings for the VC-4 EISC Client, under the IP Net Address tab, add the Room ID for the ShowRunnerCLC™ program on the VC-4 131 + 132 +===== ShowRunnerCLC™ Config Settings (Importing from a third-party VC-4, ShowRunnerCLC™ on Processor) ===== 133 + 124 124 * Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"## 125 125 * Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"## 126 -* IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead 136 +* IpAddressOrHostname will not be used, instead VCSERVERADDR console command will be used instead 127 127 128 128 ===== Processor Settings ===== 129 129 ... ... @@ -133,7 +133,7 @@ 133 133 134 134 (% class="box warningmessage" %) 135 135 ((( 136 -ShowRunnerCLC™ will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//.irtualControlEISC Client// types.146 +ShowRunnerCLC™ will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to the correct type. At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //VC-4 EISC Client// types. 137 137 ))) 138 138 139 139 (% class="box warningmessage" %)