Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 14.1
edited by Alexander Mott
on 2023/05/16 16:32
on 2023/05/16 16:32
Change comment:
There is no comment for this version
To version 10.1
edited by Alexander Mott
on 2023/05/11 15:30
on 2023/05/11 15:30
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,11 +1,6 @@ 1 1 (% class="box warningmessage" %) 2 2 ((( 3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. When importing a new or updated RSD file to the A/V program, ensure the appropriate options are selected: 4 - 5 -* "Disconnect signal from Etherenet ISC symbol in program." 6 -* "Change Locally: Update signal name in EISC ISC symbol only." 7 - 8 -[[image:MicrosoftTeams-image.png||height="413" width="394"]] 3 +Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. 9 9 ))) 10 10 11 11 ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. ... ... @@ -69,12 +69,13 @@ 69 69 ***** Scene Set and Feedback 70 70 *** Devices to be exported are defined in the configuration and are not changeable at run-time. 71 71 67 +(% class="wikigeneratedid" %) 72 72 ==== Processors with Control Subnets ==== 73 73 74 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It isnecessaryto eithersetupCWSusers and enable a secure(SCIP onport 41796) EISCor run thefollowing commands:70 +When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. These commands are the same for both 3-Series and 4-Series processors: 75 75 76 76 * ##securegateway default## 77 -** Enables non-secure connections (CIP on port 41794) from the LAN side 73 +** Enables non-secure connections (CIP on port 41794) from the LAN side instead of requiring a secure connection (SCIP on port 41796) 78 78 * ##isolatenetworks off## 79 79 ** Enables communications between the LAN and the Control Subnet, where the actual control processor is located 80 80
- MicrosoftTeams-image.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -186.5 KB - Content