Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 13.1
edited by Alexander Mott
on 2023/05/16 16:32
on 2023/05/16 16:32
Change comment:
There is no comment for this version
To version 4.1
edited by Mark Kohlmann
on 2021/06/02 22:07
on 2021/06/02 22:07
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Ethernet Intersystem Communications Export(Crestron)1 +Ethernet Intersystem Communications (Crestron) - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ IntegrationsGuide.IntegrationOptions.WebHome1 +SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,15 +1,5 @@ 1 -(% class="box warningmessage" %) 2 -((( 3 -Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. When importing a new or updated RSD file, make sure the appropriate options are selected: 1 +ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. 4 4 5 -* "Disconnect signal from Etherenet ISC symbol in program." 6 -* "Change Locally: Update signal name in EISC ISC symbol only." 7 - 8 -[[image:MicrosoftTeams-image.png||height="413" width="394"]] 9 -))) 10 - 11 -ShowRunnerCLC™ provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. 12 - 13 13 * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types 14 14 * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart 15 15 * An RSD file will be built for each EISC and a URL will be displayed on the touchscreen to retrieve it ... ... @@ -40,8 +40,7 @@ 40 40 **** All Shade Open/Close 41 41 **** Shade Name 42 42 **** Shade Open/Close/Stop 43 -**** Ignore Fade Times option set 44 -***** Fade Times are not sent out, only final value. Reduces traffic. 33 +**** 45 45 ** Device Export 46 46 *** Exports devices with specific signals for each device type 47 47 **** Occupancy Sensor ... ... @@ -67,47 +67,9 @@ 67 67 ***** Sensor Reading 68 68 **** Area 69 69 ***** Scene Set and Feedback 70 -*** Devices to be exported are defined in the configuration and are not changeable at run-tim e.59 +*** Devices to be exported are defined in the configuration and are not changeable at run-tim 71 71 72 -==== Processors with Control Subnets ==== 73 - 74 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It is necessary to either set up CWS users and enable a secure (SCIP on port 41796) EISC or run the following commands: 75 - 76 -* ##securegateway default## 77 -** Enables non-secure connections (CIP on port 41794) from the LAN side 78 -* ##isolatenetworks off## 79 -** Enables communications between the LAN and the Control Subnet, where the actual control processor is located 80 - 81 -==== VC-4 Specific Notes ==== 82 - 83 -===== Prerequisites ===== 84 - 85 -* VC-4 server installed 86 -* Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]] 87 -** Will require SETCSAUTHENTICATION command on processor 88 -** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION 89 -* ShowRunnerCLC™ running on a processor 90 -* EISC created in the ShowRunnerCLC™ config 91 -* AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4 92 - 93 -===== ShowRunnerCLC™ Config Settings ===== 94 - 95 -* Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"## 96 -* Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"## 97 -* IpAddressOrHostname will not used, instead VCSERVERADDR will be used instead 98 - 99 -===== Processor Settings ===== 100 - 101 -* Use console command VCSERVERADDR (or processor configuration pages) to add the VC-4 server IP address or hostname. Example: ##VCSERVERADDR my-vc-4-server.mycorpnet.com## 102 -* If security (hardening) is enabled use console command SETCSAUTHENTICATION to enroll the credentials used to login to VC-4. Example: ##SETCSAUTHENTICATION -n:vc4user -p:vc4password## 103 -* Reboot after entering the above settings 104 - 105 105 (% class="box warningmessage" %) 106 106 ((( 107 - ShowRunnerCLC™ will generatethe RSD file as anEISC type,the SIMPL Windows programmerwill needtoconvert the symbolton//EISC Server//. At thetimeofthiswriting,Crestron doesnotallowimport/export ofRSD filesfor //EISCClient//, //EISC Server,//and//VirtualControlEISC Client//types.63 +Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. 108 108 ))) 109 - 110 -(% class="box warningmessage" %) 111 -((( 112 -ShowRunnerCLC™ uses analog join 4001 on normal EISCs to confirm the logic is fully online. Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead. 113 -)))
- MicrosoftTeams-image.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -186.5 KB - Content