Last modified by Mark Kohlmann on 2024/11/19 23:23

From version 10.1
edited by Alexander Mott
on 2023/05/11 15:30
Change comment: There is no comment for this version
To version 9.1
edited by Scott Kohlmann
on 2023/04/20 21:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
1 +XWiki.scott\.kohlmann@chiefintegrations\.com
Content
... ... @@ -64,16 +64,6 @@
64 64  ***** Scene Set and Feedback
65 65  *** Devices to be exported are defined in the configuration and are not changeable at run-time.
66 66  
67 -(% class="wikigeneratedid" %)
68 -==== Processors with Control Subnets ====
69 -
70 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. These commands are the same for both 3-Series and 4-Series processors:
71 -
72 -* ##securegateway default##
73 -** Enables non-secure connections (CIP on port 41794) from the LAN side instead of requiring a secure connection (SCIP on port 41796)
74 -* ##isolatenetworks off##
75 -** Enables communications between the LAN and the Control Subnet, where the actual control processor is located
76 -
77 77  ==== VC-4 Specific Notes ====
78 78  
79 79  ===== Prerequisites =====