Changes for page Ethernet Intersystem Communications Export (Crestron)
Last modified by Mark Kohlmann on 2024/11/19 23:23
From version 10.1
edited by Alexander Mott
on 2023/05/11 15:30
on 2023/05/11 15:30
Change comment:
There is no comment for this version
To version 8.1
edited by Mark Kohlmann
on 2022/09/30 19:41
on 2022/09/30 19:41
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -3,7 +3,7 @@ 3 3 Note: Any changes to load hardware/scene quantity will require a regeneration of the EISC and will result in signal changes. 4 4 ))) 5 5 6 -ShowRunner CLC™provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems.6 +ShowRunner provides Ethernet Intersystem Communications interfaces for integration with 3rd party Crestron systems. 7 7 8 8 * EISCs may be Classic, 3-Series, or Server/Client (VC-4) types 9 9 * EISCs can have their IP-ID and IP Address of the remote changed at run-time without a program restart ... ... @@ -64,16 +64,6 @@ 64 64 ***** Scene Set and Feedback 65 65 *** Devices to be exported are defined in the configuration and are not changeable at run-time. 66 66 67 -(% class="wikigeneratedid" %) 68 -==== Processors with Control Subnets ==== 69 - 70 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. These commands are the same for both 3-Series and 4-Series processors: 71 - 72 -* ##securegateway default## 73 -** Enables non-secure connections (CIP on port 41794) from the LAN side instead of requiring a secure connection (SCIP on port 41796) 74 -* ##isolatenetworks off## 75 -** Enables communications between the LAN and the Control Subnet, where the actual control processor is located 76 - 77 77 ==== VC-4 Specific Notes ==== 78 78 79 79 ===== Prerequisites ===== ... ... @@ -80,13 +80,13 @@ 80 80 81 81 * VC-4 server installed 82 82 * Recommended VC-4 server hardened per [[Crestron>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]] 83 -** Will require SETCSAUTHENTICATION command on processor 73 +** [[>>https://support.crestron.com/app/answers/detail/a_id/1001249/kw/harden%20VC-4]]Will require SETCSAUTHENTICATION command on processor 84 84 ** VC-4 installer will need to provide username and password for processor to connect, this is used with SETCSAUTHENTICATION 85 -* ShowRunnerCLC™running on a processor86 -* EISC created in the ShowRunnerCLC™config75 +* showrunner running on a processor 76 +* EISC created in the showrunner config 87 87 * AV program running on VC-4, AV programmer will need to provide the ROOM ID from VC-4 88 88 89 -===== ShowRunnerCLC™Config Settings =====79 +===== showrunner Config Settings ===== 90 90 91 91 * Define EiscType in config: ##"EiscType": "VirtualControlEiscClient"## 92 92 * Define Vc4RoomId in config: ##"Vc4RoomId": "VC4ROOMID"## ... ... @@ -100,10 +100,10 @@ 100 100 101 101 (% class="box warningmessage" %) 102 102 ((( 103 - ShowRunnerCLC™will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//. At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types.93 +showrunner will generate the RSD file as an EISC type, the SIMPL Windows programmer will need to convert the symbol to an //EISC Server//. At the time of this writing, Crestron does not allow import/export of RSD files for //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types. 104 104 ))) 105 105 106 106 (% class="box warningmessage" %) 107 107 ((( 108 - ShowRunnerCLC™uses analog join 4001 on normal EISCs to confirm the logic is fully online. Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead.98 +showrunner uses analog join 4001 on normal EISCs to confirm the logic is fully online. Join 4001 is not available on //EISC Client//, //EISC Server,// and //Virtual Control EISC Client// types so 4000 is used instead. 109 109 )))