Last modified by Mark Kohlmann on 2024/11/19 23:23

From version 10.1
edited by Alexander Mott
on 2023/05/11 15:30
Change comment: There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2023/05/11 15:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -64,13 +64,12 @@
64 64  ***** Scene Set and Feedback
65 65  *** Devices to be exported are defined in the configuration and are not changeable at run-time.
66 66  
67 -(% class="wikigeneratedid" %)
68 68  ==== Processors with Control Subnets ====
69 69  
70 -When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. These commands are the same for both 3-Series and 4-Series processors:
69 +When integrating a 3-Series EISC with a processor that has both a LAN port and a Control Subnet using a connection over the LAN, there are some additional settings that need to be enabled in order for the integration to work correctly. It is necessary to either set up CWS users and enable a secure (SCIP on port 41796) EISC or run the following commands:
71 71  
72 72  * ##securegateway default##
73 -** Enables non-secure connections (CIP on port 41794) from the LAN side instead of requiring a secure connection (SCIP on port 41796)
72 +** Enables non-secure connections (CIP on port 41794) from the LAN side
74 74  * ##isolatenetworks off##
75 75  ** Enables communications between the LAN and the Control Subnet, where the actual control processor is located
76 76