Wiki source code of DMX Input via Pharos
Version 4.2 by Mark Kohlmann on 2021/07/14 16:24
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
2.1 | 1 | SHOWRUNNER™ can accept commands from a Pharos' DMX input. Note: Pharos recommends not using anymore than 50 channels on the DMX input. |
| 2 | |||
| 3 | Steps: | ||
| 4 | |||
| 5 | SHOWRUNNER™ | ||
| 6 | |||
| |
3.1 | 7 | 1. Enable [[UDP Listener>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.UDP Input.WebHome]] in the SHOWRUNNER™ config: |
| |
2.1 | 8 | |
| 9 | "UdpListener": | ||
| 10 | { | ||
| 11 | "ListenPort": 45794 | ||
| 12 | }, | ||
| 13 | |||
| 14 | Pharos Config: | ||
| 15 | |||
| 16 | 1. Create a new Pharos Project or Open an Existing One | ||
| 17 | 1. Go to Project->Project Features and set DMX In under Trigger to Enabled | ||
| 18 | 1. Go to Network->Select Controller with DMX Input->Interfaces and set the Serial Port to DMX Input | ||
| 19 | 1. Triggers | ||
| 20 | 11. Create a trigger on each DMX Input that you wish to send to SHOWRUNNER™ | ||
| 21 | 11. Set Trigger Parameters: | ||
| 22 | 111. Channel: Channel # you wish to capture | ||
| 23 | 111. Changes in range: Minimum: 0 Maximum: 255 | ||
| 24 | 11. New Action: Output Ethernet | ||
| 25 | 111. Enable Variables | ||
| 26 | 111. IP/Hostname: IP Address or Hostname of the processor running SHOWRUNNER™ | ||
| 27 | 111. Port: 45794 | ||
| 28 | 111. Protocol: UDP | ||
| 29 | 111. String: "GID.SetLevelByByte.<3>\r" | ||
| 30 | 1111. GID is the GlobalID for the load within SHOWRUNNER™ | ||
| 31 | 111. Example DMX Channel 41 controlling load with global ID of 32: | ||
| 32 | [[image:1597260805025-107.png||height="58" width="693"]] | ||
| 33 | |||
| 34 |