Version 6.1 by Alexander Mott on 2023/03/28 19:00

Hide last authors
Alexander Mott 1.1 1 (% class="box errormessage" %)
2 (((
3 n/a
4 )))
Alexander Mott 2.1 5
Alexander Mott 1.1 6 (% class="box warningmessage" %)
7 (((
8 n/a
9 )))
Alexander Mott 2.1 10
Alexander Mott 1.1 11 {{box cssClass="floatinginfobox" title="**CONTENTS**"}}
12 {{toc/}}
13 {{/box}}
Alexander Mott 2.1 14
Alexander Mott 1.1 15 (% class="row" %)
16 (((
17 Lorem
18 See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details.
19 See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details.
Alexander Mott 2.1 20
21 = Start-Up Guide =
22
Alexander Mott 1.1 23 Lorem
Alexander Mott 3.1 24
25 (% class="box warningmessage" %)
26 (((
Alexander Mott 4.1 27 cross reference/update to old [[zumnet startup>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUMNET-JBOX Setup.WebHome]]?
Alexander Mott 3.1 28
Alexander Mott 4.1 29 basic steps:
Alexander Mott 5.1 30
Alexander Mott 3.1 31 * configure your processor per chief's startup guide
32 * get all zumnet jbox online
33 ** use built in dhcp from processor control subnet
Alexander Mott 4.1 34 ** if using proc without control subnet, use showrunner [[dhcp>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]
35 ** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**)
Alexander Mott 3.1 36 * use crestron toolbox device discovery to create a [[Device Summary>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoDeviceSummary"]]
37 * use chief tools tm tool to generate various zum wired load scripts
38 ** (need to determine exact process for this; will need to add IP-ID and new hostname to device summary somehow)
39 ** (will likely generate two versions of the loadscripts; one connecting by default hostname and one connecting by new hostname)
40 ** (intend to require SR license for zwired LS generator, if only to get the proc mac address)
41 * if firmware is old, run "zwms master/zum (def. hostname)" loadscript to make all ZUMNET JBOX primary and in app mode in order to enable discovery of devices on zumlink
42 ** devices will reboot
43 ** per crestron, 1.0006.00012 and newer ship in primary mode (**tbd if they will ship in app mode?**)
44 * connect to a few devices in device discovery tool to ensure that all zumlink devices were automatically readdressed and there are no conflicting cids
45 ** firmware 1.0001.00081 is new enough that this works correctly
46 * run "fw update (def. hostname)" loadscript to update the fw for all devices
47 ** will take up to several minutes per room, but will be able to do up to 10 rooms simultaneously
48 ** devices will reboot, possibly multiple times
49 ** check loadscript manager for any failures and re-run script for those devices if necessary (a rebooting zumnet box will temporarily disrupt online status for downstream zumnet jboxs and potentially interrupt the firmware update)
Alexander Mott 6.1 50 * run device discovery again to confirm that all zumnet boxes were updated
51 ** zumnet boxes update last, so if a zumnet jbox is updated then this means that all of the zumlink devices that were online have also been updated
52 * if app mode backup is desired, configure the boxes using the app now
Alexander Mott 3.1 53 * run "ip config (def. hostname)" loadscript to update device IP-IDs and hostnames
54 ** devices will reboot
55 ** devices will now have new hostnames, so any further loadscripts should use (new hostname) versions
Alexander Mott 6.1 56 * run "cnet mode (def. hostname)" loadscript to put devices into CNET mode
57 ** if app mode backup is desired, also run "autoswitch enable (def. hostname)" loadscript
58 ** devices will reboot
Alexander Mott 3.1 59 * if using a processor without control subnet, run the "static ip config (new hostname)" script
60 ** this loadscript is necessary, as the showrunner DHCP server is only intended for commissioning. It must always be manually started after program restart and should not be used in production
61 ** (**will probably need a lot of extra steps + alterations to how we make configs since static IPs require a lot more information as well as corresponding modifications to SrConfig.json**)
Alexander Mott 5.1 62 * once done, commission job essentially as normal showrunner job
63 ** (**sr commissioning guide is incomplete**)
Alexander Mott 6.1 64 ** connect to each zumnet jbox and address zumlink devices per the takeoff
65 *** if devices are not online, then troubleshoot why and update firmware through device tree view once they are online
Alexander Mott 5.1 66 ** occ timeouts can be adjusted through UI; other settings (ie reach) should be adjusted through app
67 ** photocells etc are set up through UI
68 ** loads teseted and verified through UI; can be moved around between controllers as necessary
69 *** loads don't need to be in the same room as the zumnet that controls them
70 ** keypads can use standard SR types or be fully customized
71 ** set up schedule, etc.
Alexander Mott 6.1 72 * once done, save and back up configuration file
Alexander Mott 1.1 73 )))
Alexander Mott 3.1 74 )))