From version < 3.19 >
edited by Mark Kohlmann
on 2020/04/14 20:58
To version < 3.20 >
edited by Mark Kohlmann
on 2020/04/14 20:59
< >
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -34,6 +34,8 @@
34 34  |Plug Load On/Off|Y|Y|Y|Y|By Hardware
35 35  |Integration with Non-Zūm Hardware|Y|Y|N|N|N
36 36  |Custom Zūm Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware
37 +|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive
38 +Floor Hub: 6-12 months|6-12 months|6-12 months
37 37  |(% colspan="6" %)**Calendar/Scheduling**
38 38  |Logic Type|Event Driven
39 39  Profile Support (Under Development)|Event Driven
... ... @@ -45,18 +45,55 @@
45 45  |Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License
46 46  Floor Hub: N|N|N/A
47 47  |(% colspan="6" %)**Integrations**
50 +|A/V Integration: API|Y|Y|SHOWRUNNER™: Y
51 +Floor Hub: Limited|Limited|N/A
52 +|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y
53 +Floor Hub: N|N|N/A
54 +|A/V Integration: RS-232|Y|Y|(((
55 +SHOWRUNNER™: Y
56 +Floor Hub: AVBRIDGE per Area
57 +)))|AVBRIDGE per Area|N/A
48 48  |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|(((
49 49  SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed
50 50  Floor Hub: Y
51 51  )))|Y|N/A
52 -|BACNET Features|Area Scene, Load Control, Occupancy Status/Enable/Disable|Area Scene, Load Control, Occupancy Status/Enable/Disable|(((
53 -SHOWRUNNER™: See list to the left
54 -Floor Hub:
55 -)))| |N/A
62 +|BACNET Features|(((
63 +Per Area Status:
64 +Active Scene
65 +Occupied
66 +Occupancy Enabled
67 +Individual Load Level
68 +Photocell Level (per Photocell)
69 +
70 +System:
71 +Demand Response Enabled
72 +System Wide Override (Panic/Emergency)
73 +)))|See list for SHOWRUNNER™ Total Control|(((
74 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control
75 +Floor Hub: See list for ZUM-FLOOR-HUB
76 +)))|(((
77 +Per Room Status:
78 +Online
79 +On
80 +Occupied
81 +Daylighting Active
82 +Device Battery is Low
83 +Plug Loads Enabled
84 +Occupancy Sensor Enabled
85 +Current Daylight Level
86 +Active Scene
87 +\\System:
88 +Demand Response Enabled
89 +)))|N/A
56 56  |BACNET Settings Scope|Per Area|Per Area|(((
57 57  SHOWRUNNER™: Per Area
58 58  Floor Hub: Global
59 59  )))|Global|N/A
94 +|Crestron Fusion|Y|Y|(((
95 +SHOWRUNNER™: Y
96 +Floor Hub: N
97 +)))|N|N/A
98 +| | | | | |
60 60  
61 61  ##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.##
62 62  ##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (Apr 2020).##