... ... @@ -15,7 +15,7 @@
15 15  |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A
16 16  |Requires Dedicated RS-232 Serial Port per Room|N|Y|N|N|N/A
17 17  |Requires 3 or 4-Series Control System|Y|Y|Y|N|N/A
18 -|Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y
18 +|Requires Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y
19 19  |(% colspan="6" %)**User Interfaces**
20 20  |Web Browser|(((
21 21  Crestron SmartGraphics XPanel
... ... @@ -26,10 +26,10 @@
26 26  |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
27 27  |Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N
28 28  |(% colspan="6" %)**Features**
29 -|Scene Recall|Y|Y|Y|Y|Y
30 -|Override Fade Time for Scene Recall~*~*|Y|N|N|N|N
31 -|Scene Save|Y|Y|N|N|Y
32 -|Load Control|Y|Y|N|N|Y
29 +|Scene Recall|Y ~*~*~*~*|Y ~*~*~*~*|Y|Y|Y
30 +|Override Fade Time for Scene Recall ~*~*|Y|N|N|N|N
31 +|Scene Save|Y ~*~*~*~*|Y ~*~*~*~*|N|N|Y
32 +|Load Control|Y ~*~**|Y ~*~**|N|N|Y
33 33  |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N
34 34  |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y
35 35  |Override Occupancy Logic|Y|Y|N|N|N
... ... @@ -127,8 +127,11 @@
127 127  Floor Hub: N
128 128  )))|N|N/A
129 129  
130 -##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.##
131 -##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).##
130 +{{{* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.
131 +** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).
132 +*** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer.
133 +**** Zūm wireless scenes cannot presently be read. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer.
134 +}}}
132 132  
133 133  