Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 39.2
edited by Scott Kohlmann
on 2023/04/20 22:25
on 2023/04/20 22:25
Change comment:
There is no comment for this version
To version 29.1
edited by Mark Kohlmann
on 2021/07/22 22:29
on 2021/07/22 22:29
Change comment:
There is no comment for this version
Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Design Guide.Hardware Design Guide.WebHome 1 +SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. scott\.kohlmann@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - false1 +true - Content
-
... ... @@ -1,15 +1,15 @@ 1 -Crestron Zūm Wireless is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. S howRunnerCLC™ provides a number of integrations options that allow the designer to optimize the solution design.1 +Crestron Zūm Wireless is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design. 2 2 3 3 ==== Integration Options ==== 4 4 5 -* **S howRunnerCLC™ Total Control** - The most comprehensive option. Allows seamless (see [[Caveats>>WebHome||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design.6 -* **S howRunnerCLC™ + AVBRIDGE + Serial Port** - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room. Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room.7 -* **S howRunnerCLC™+ ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. ShowRunnerCLC™ can export its own areas to the Floor Hub.5 +* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless (see [[Caveats>>||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design. 6 +* **SHOWRUNNER™ + AVBRIDGE + Serial Port** - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room. Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room. 7 +* **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub. 8 8 9 9 ==== Feature Matrix ==== 10 10 11 11 (% border="1" style="margin-left:auto; margin-right:auto" %) 12 -|=Feature|=S howRunnerCLC™ Total Control|=ShowRunnerCLC™ + AVBRIDGE + Serial Port|=ShowRunnerCLC™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*12 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 13 13 |(% colspan="6" %)**Hardware Requirements** 14 14 |Requires JBOX with ZUMMESH-NETBRIDGE|Y|N|Y|Y|Y 15 15 |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A ... ... @@ -21,7 +21,7 @@ 21 21 Crestron SmartGraphics XPanel 22 22 HTML5 UI Under Development (Q2 2021) 23 23 )))|Crestron SmartGraphics XPanel 24 -HTML5 UI Under Development (Q2 2021)|S howRunnerCLC™ - Crestron SmartGraphics XPanel24 +HTML5 UI Under Development (Q2 2021)|SHOWRUNNER™ - Crestron SmartGraphics XPanel 25 25 ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 26 26 |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 27 27 |Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N ... ... @@ -30,56 +30,53 @@ 30 30 |Override Fade Time for Scene Recall ~*~*|Y|N|N|N|N 31 31 |Scene Save|Y ~*~*~*~*|Y ~*~*~*~*|N|N|Y 32 32 |Load Control|Y ~*~**/~*~*~*~**|Y ~*~**|N|N|Y 33 -|Demand Response|Y|N|Y, separate triggers for S howRunnerCLC™ and ZUM-FLOOR-HUB required|Y|N33 +|Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 34 34 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 35 35 |Override Occupancy Logic|Y|Y|N|N|N 36 -|Override|Y~*~*~*~*~*~*|N|Scene Recall only via ShowRunner CLC™|N|N/A36 +|Override|Y~*~*~*~*~*~*|N|Scene Recall only via ShowRunner|N|N/A 37 37 |Plug Load On/Off|Y|Y|Y|Y|By Hardware 38 38 |Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 39 -|Custom Zūm Keypad Programming|((( 40 -Y, per individual button (1 through 4) 41 -AV Keypad not required (v3.004 or later) 42 -[[Details>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.Zummesh Keypad Custom Programming.WebHome]] 43 -)))|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 44 -|New Feature Release Cycle|Aggressive|Aggressive|ShowRunnerCLC™: Aggressive 39 +|Custom Zūm Keypad Programming|Y, per individual button 40 +AV Keypad not required (v3.004 or later)|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 41 +|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 45 45 Floor Hub: 6-12 months|6-12 months|6-12 months 46 46 |Room Organization|((( 47 47 Under Development: 48 48 Building/Floor/Sub-Group/Area 49 49 Categorization to Filter by Category/Tag 50 -)))|See S howRunnerCLC™ Total Control|ShowRunnerCLC™: See ShowRunnerCLC™ Total Control47 +)))|See SHOWRUNNER™ Total Control|SHOWRUNNER™: See SHOWRUNNER™ Total Control 51 51 Floor Hub: Category/Room|Category/Room|((( 52 52 N/A 53 53 ))) 54 -|Room Discovery|Automatic Discovery of Gateways and NETBRIDGES|Pre-Configured at Order|S howRunnerCLC™: Pre-Configured at Order55 -Floor Hub: Map Mirrored Rooms to S howRunnerCLC™ and Discovery External Rooms|Automatic Discovery of Gateways and NETBRIDGES|N/A51 +|Room Discovery|Automatic Discovery of Gateways and NETBRIDGES|Pre-Configured at Order|SHOWRUNNER™: Pre-Configured at Order 52 +Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of Gateways and NETBRIDGES|N/A 56 56 |Firmware Updates|PUF Tool 57 57 Automatic Support on Roadmap|((( 58 58 PUF Tool 59 59 Automatic Support on Roadmap 60 -)))|S howRunnerCLC™: PUF Tool57 +)))|SHOWRUNNER™: PUF Tool 61 61 Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A 62 62 |(% colspan="6" %)**Calendar/Scheduling** 63 63 |Logic Type|Event Driven 64 64 Profile Support (Under Development)|Event Driven 65 -Profile Support (Under Development)|S howRunnerCLC™: Event Driven62 +Profile Support (Under Development)|SHOWRUNNER™: Event Driven 66 66 Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A 67 67 |Astronomical Clock|Y|Y|Y, Per Category|Y, Per Category|N/A 68 -|Holidays|Pattern|Pattern|S howRunnerCLC™: Pattern65 +|Holidays|Pattern|Pattern|SHOWRUNNER™: Pattern 69 69 Floor Hub: Hard Coded|Hard Coded|N/A 70 -|Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|S howRunnerCLC™: Y, Advanced Scheduler License67 +|Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License 71 71 Floor Hub: N|N|N/A 72 72 |(% colspan="6" %)**Integrations** 73 -|A/V Integration: API|Y|Y|S howRunnerCLC™: Y70 +|A/V Integration: API|Y|Y|SHOWRUNNER™: Y 74 74 Floor Hub: Limited|Limited|N/A 75 -|A/V Integration: Crestron EISC|Y|Y|S howRunnerCLC™: Y72 +|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y 76 76 Floor Hub: N|N|N/A 77 77 |A/V Integration: RS-232|Y|Y|((( 78 -S howRunnerCLC™: Y75 +SHOWRUNNER™: Y 79 79 Floor Hub: AVBRIDGE per Area 80 80 )))|AVBRIDGE per Area|N/A 81 -|BACNET|Y, S howRunnerCLC™ and Crestron Licenses Needed|Y, ShowRunnerCLC™ and Crestron Licenses Needed|(((82 -S howRunnerCLC™: ShowRunnerCLC™ and Crestron Licenses Needed78 +|BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 79 +SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed 83 83 Floor Hub: Y 84 84 )))|Y|N/A 85 85 |BACNET Features|((( ... ... @@ -96,8 +96,8 @@ 96 96 System Wide Override (Panic/Emergency) 97 97 98 98 ~* More Features added upon request 99 -)))|See list for S howRunnerCLC™ Total Control|(((100 -S howRunnerCLC™: See list for ShowRunnerCLC™ Total Control96 +)))|See list for SHOWRUNNER™ Total Control|((( 97 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control 101 101 Floor Hub: See list for ZUM-FLOOR-HUB 102 102 )))|((( 103 103 Per Room Status: ... ... @@ -139,8 +139,8 @@ 139 139 ** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 140 140 *** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 141 141 **** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time. 142 -***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. Sometimes delays in sending load levels occur. Feature is primarily intended for remotely setting scenes.143 -****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors and recall scene 15.The occupancy sensor enabled state and current scene will be remembered and recalled when leaving occupancy mode.139 +***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 140 +****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors. 144 144 }}} 145 145 146 146 {{id name="caveats"/}} ... ... @@ -153,7 +153,7 @@ 153 153 * Lower operations can turn the load off. The load will not come on with a raise. This is a firmware behavior in the Zum hardware. 154 154 * Wireless control presents some additional latency possibilities. Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load. Local operation of the Zum wireless room is not impacted. 155 155 * Real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 156 -* Keypad behaviors cannot be modified in ShowRunner. Some modifications are permitted within the Zum app. Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose ; or via export buttons ([[Details>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.Zummesh Keypad Custom Programming.WebHome]]).153 +* Keypad behaviors cannot be modified in ShowRunner. Some modifications are permitted within the Zum app. Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose. 157 157 * Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic externally to the linked Zum rooms. 158 158 * Off Scene cannot be saved and is always room Off 159 159 * Scenes 1 through 16 are supported and may be modified and saved.