Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
To version 32.1
edited by Mark Kohlmann
on 2021/07/26 18:04
on 2021/07/26 18:04
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Design Guide.Hardware Design Guide.WebHome 1 +SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a lexander\.mott@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 ==== Integration Options ==== 4 4 5 -* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless (see [[Caveats>> WebHome||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design.5 +* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless (see [[Caveats>>||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design. 6 6 * **SHOWRUNNER™ + AVBRIDGE + Serial Port** - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room. Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room. 7 7 * **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub. 8 8 ... ... @@ -39,7 +39,7 @@ 39 39 |Custom Zūm Keypad Programming|((( 40 40 Y, per individual button (1 through 4) 41 41 AV Keypad not required (v3.004 or later) 42 -[[Details>>doc:SHOWRUNNER™ SetupGuide.TroubleshootingGuide.Advanced Tools.Zummesh Keypad Custom Programming.WebHome]]42 +[[Details>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.Zummesh Keypad Custom Programming.WebHome]] 43 43 )))|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 44 44 |New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 45 45 Floor Hub: 6-12 months|6-12 months|6-12 months ... ... @@ -153,7 +153,7 @@ 153 153 * Lower operations can turn the load off. The load will not come on with a raise. This is a firmware behavior in the Zum hardware. 154 154 * Wireless control presents some additional latency possibilities. Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load. Local operation of the Zum wireless room is not impacted. 155 155 * Real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 156 -* Keypad behaviors cannot be modified in ShowRunner. Some modifications are permitted within the Zum app. Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose ; or via export buttons ([[Details>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.Zummesh Keypad Custom Programming.WebHome]]).156 +* Keypad behaviors cannot be modified in ShowRunner. Some modifications are permitted within the Zum app. Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose. 157 157 * Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic externally to the linked Zum rooms. 158 158 * Off Scene cannot be saved and is always room Off 159 159 * Scenes 1 through 16 are supported and may be modified and saved.