Changes for page Crestron Zūm Wireless

Last modified by Scott Kohlmann on 2023/04/20 22:28

From version 36.1
edited by Mark Kohlmann
on 2022/06/15 22:26
Change comment: There is no comment for this version
To version 33.1
edited by Mark Kohlmann
on 2021/12/08 00:15
Change comment: Renamed from xwiki:SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.Crestron Zūm Wireless.WebHome

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Design Guide.Hardware Design Guide.WebHome
1 +SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome
Content
... ... @@ -2,7 +2,7 @@
2 2  
3 3  ==== Integration Options ====
4 4  
5 -* **SHOWRUNNER™ Total Control** - The most comprehensive option.  Allows seamless (see [[Caveats>>WebHome||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products.  Extensive feature set allows centralized control and management of Zūm rooms.  Advanced scheduler provides more flexibility to the facility operator.  This solution replaces the ZUM-FLOOR-HUB in the system design.
5 +* **SHOWRUNNER™ Total Control** - The most comprehensive option.  Allows seamless (see [[Caveats>>||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products.  Extensive feature set allows centralized control and management of Zūm rooms.  Advanced scheduler provides more flexibility to the facility operator.  This solution replaces the ZUM-FLOOR-HUB in the system design.
6 6  * **SHOWRUNNER™ + AVBRIDGE + Serial Port** - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room.  Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room.
7 7  * **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub.  SHOWRUNNER™ can export its own areas to the Floor Hub.
8 8  
... ... @@ -153,7 +153,7 @@
153 153  * Lower operations can turn the load off.  The load will not come on with a raise.  This is a firmware behavior in the Zum hardware.
154 154  * Wireless control presents some additional latency possibilities.  Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load.  Local operation of the Zum wireless room is not impacted.
155 155  * Real time load status is not available.  Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner.  Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner.
156 -* Keypad behaviors cannot be modified in ShowRunner.  Some modifications are permitted within the Zum app.  Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose; or via export buttons ([[Details>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.Zummesh Keypad Custom Programming.WebHome]]).
156 +* Keypad behaviors cannot be modified in ShowRunner.  Some modifications are permitted within the Zum app.  Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose.
157 157  * Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic externally to the linked Zum rooms.
158 158  * Off Scene cannot be saved and is always room Off