Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 36.1
edited by Mark Kohlmann
on 2022/06/15 22:26
on 2022/06/15 22:26
Change comment:
There is no comment for this version
To version 25.1
edited by Mark Kohlmann
on 2021/03/23 20:48
on 2021/03/23 20:48
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Design Guide.Hardware Design Guide.WebHome 1 +SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome - Content
-
... ... @@ -2,7 +2,7 @@ 2 2 3 3 ==== Integration Options ==== 4 4 5 -* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless (see [[Caveats>> WebHome||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design.5 +* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless (see [[Caveats>>||anchor="caveats"]]) integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design. 6 6 * **SHOWRUNNER™ + AVBRIDGE + Serial Port** - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room. Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room. 7 7 * **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub. 8 8 ... ... @@ -33,14 +33,9 @@ 33 33 |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 34 34 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 35 35 |Override Occupancy Logic|Y|Y|N|N|N 36 -|Override|Y~*~*~*~*~*~*|N|Scene Recall only via ShowRunner|N|N/A 37 37 |Plug Load On/Off|Y|Y|Y|Y|By Hardware 38 38 |Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 39 -|Custom Zūm Keypad Programming|((( 40 -Y, per individual button (1 through 4) 41 -AV Keypad not required (v3.004 or later) 42 -[[Details>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.Zummesh Keypad Custom Programming.WebHome]] 43 -)))|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 38 +|Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 44 44 |New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 45 45 Floor Hub: 6-12 months|6-12 months|6-12 months 46 46 |Room Organization|((( ... ... @@ -131,8 +131,8 @@ 131 131 SHOWRUNNER™: Y 132 132 Floor Hub: N 133 133 )))|N|N/A 134 -|Minimum NETBRIDGE Firmware|v1.1 3.0020(PUF Zum MESHNET v1.07.16)|v1.010|N/A|See Crestron|See Crestron135 -|Minimum Gateway Firmware|v1.4469.000 22|N/A|N/A|See Crestron|See Crestron129 +|Minimum NETBRIDGE Firmware|v1.12.0130 (PUF Zum MESHNET v1.06.09)|v1.010|N/A|See Crestron|See Crestron 130 +|Minimum Gateway Firmware|v1.4469.00011|N/A|N/A|See Crestron|See Crestron 136 136 |Minimum SHOWRUNNER™ Version|2.198|2.198|N/A|N/A|N/A 137 137 138 138 {{{* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App. ... ... @@ -139,9 +139,7 @@ 139 139 ** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 140 140 *** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 141 141 **** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time. 142 -***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. Sometimes delays in sending load levels occur. Feature is primarily intended for remotely setting scenes. 143 -****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors and recall scene 15. The occupancy sensor enabled state and current scene will be remembered and recalled when leaving occupancy mode. 144 -}}} 137 +***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. }}} 145 145 146 146 {{id name="caveats"/}} 147 147 ... ... @@ -153,8 +153,8 @@ 153 153 * Lower operations can turn the load off. The load will not come on with a raise. This is a firmware behavior in the Zum hardware. 154 154 * Wireless control presents some additional latency possibilities. Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load. Local operation of the Zum wireless room is not impacted. 155 155 * Real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 156 -* Keypad behaviors cannot be modified in ShowRunner.Some modifications are permitted within the Zum app.Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose; or via export buttons ([[Details>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.Zummesh Keypad Custom Programming.WebHome]]).157 -* Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic externally to the linked Zum rooms.149 +* Keypad behaviors cannot be modified. Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose. 150 +* Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic. 158 158 * Off Scene cannot be saved and is always room Off 159 159 * Scenes 1 through 16 are supported and may be modified and saved. 160 160 * Scenes with fade times greater than 1 second will result in loads being commanded individual from ShowRunner and may not be in sync depending on load quantity, RF gateway load, and RF signal integrity. Zum hardware does not support a fade time as part of the Scene setting. Fade times must be commanded from ShowRunner. Scene fade times will be ignored when scenes are activated by Zum keypads or internal occupancy logic. ... ... @@ -165,10 +165,10 @@ 165 165 * Blink before timeout is not supported 166 166 * CCT control is presently not supported (ZUMMESH-JBOX-DALI support may be available in the future) 167 167 * RGB loads are not supported 168 -* Minimum/Maximum Levels are not supported when loads are being recalled locally. ShowRunner will honor them when control occurs from ShowRunner except for raise/lower which is pe rformed on hardware.161 +* Minimum/Maximum Levels are not supported when loads are being recalled locally. ShowRunner will honor them when control occurs from ShowRunner except for raise/lower which is peformed on hardware. 169 169 * Dimming curves are not supported when loads are being recalled locally. Use Zum app to adjust dimming curves if necessary. Recommended to leave ShowRunner dimming curve set to "Unaffected". 170 170 * BACNET support requires a processor hardware license and ShowRunner BACNET license. BACNET point availability can be configured per Area. 171 -* Chief Integrations recommends one 4-series (preferred) or3-series processor per building floor at a minimum.164 +* Chief Integrations recommends one 3-series processor per building floor at a minimum. 172 172 * Zummesh and infiNET EX devices are not officially supported on the same gateway, discuss with Crestron if needing both. 173 173 174 174 (% id="HTopologies" %)