Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 32.1
edited by Mark Kohlmann
on 2021/07/26 18:04
on 2021/07/26 18:04
Change comment:
There is no comment for this version
To version 29.1
edited by Mark Kohlmann
on 2021/07/22 22:29
on 2021/07/22 22:29
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -36,11 +36,8 @@ 36 36 |Override|Y~*~*~*~*~*~*|N|Scene Recall only via ShowRunner|N|N/A 37 37 |Plug Load On/Off|Y|Y|Y|Y|By Hardware 38 38 |Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 39 -|Custom Zūm Keypad Programming|((( 40 -Y, per individual button (1 through 4) 41 -AV Keypad not required (v3.004 or later) 42 -[[Details>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.Zummesh Keypad Custom Programming.WebHome]] 43 -)))|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 39 +|Custom Zūm Keypad Programming|Y, per individual button 40 +AV Keypad not required (v3.004 or later)|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 44 44 |New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 45 45 Floor Hub: 6-12 months|6-12 months|6-12 months 46 46 |Room Organization|((( ... ... @@ -139,8 +139,8 @@ 139 139 ** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 140 140 *** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 141 141 **** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time. 142 -***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. Sometimes delays in sending load levels occur. Feature is primarily intended for remotely setting scenes.143 -****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors and recall scene 15.The occupancy sensor enabled state and current scene will be remembered and recalled when leaving occupancy mode.139 +***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 140 +****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors. 144 144 }}} 145 145 146 146 {{id name="caveats"/}}