Changes for page Crestron Zūm Wireless

Last modified by Scott Kohlmann on 2023/04/20 22:28

From version 3.27
edited by Mark Kohlmann
on 2020/04/14 21:10
Change comment: (Autosaved)
To version 3.19
edited by Mark Kohlmann
on 2020/04/14 20:58
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -8,7 +8,7 @@
8 8  
9 9  ==== Feature Matrix ====
10 10  
11 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
11 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ + ZUM-FLOOR-HUB|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
12 12  |(% colspan="6" %)**Hardware Requirements**
13 13  |Requires JBOX and ZUMMESH-NETBRIDGE|Y|N|Y|Y|Y
14 14  |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A
... ... @@ -32,18 +32,8 @@
32 32  |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y
33 33  |Override Occupancy Logic|Y|Y|N|N|N
34 34  |Plug Load On/Off|Y|Y|Y|Y|By Hardware
35 -|Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N
36 -|Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware
37 -|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive
38 -Floor Hub: 6-12 months|6-12 months|6-12 months
39 -|Room Organization|(((
40 -Under Development:
41 -Building/Floor/Sub-Group/Area
42 -Categorization to Filter by Different Types
43 -)))|See SHOWRUNNER™ Total Control|SHOWRUNNER™: See SHOWRUNNER™ Total Control
44 -Floor Hub: Category/Room|Category/Room|(((
45 -N/A
46 -)))
35 +|Integration with Non-Zūm Hardware|Y|Y|N|N|N
36 +|Custom Zūm Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware
47 47  |(% colspan="6" %)**Calendar/Scheduling**
48 48  |Logic Type|Event Driven
49 49  Profile Support (Under Development)|Event Driven
... ... @@ -55,55 +55,18 @@
55 55  |Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License
56 56  Floor Hub: N|N|N/A
57 57  |(% colspan="6" %)**Integrations**
58 -|A/V Integration: API|Y|Y|SHOWRUNNER™: Y
59 -Floor Hub: Limited|Limited|N/A
60 -|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y
61 -Floor Hub: N|N|N/A
62 -|A/V Integration: RS-232|Y|Y|(((
63 -SHOWRUNNER™: Y
64 -Floor Hub: AVBRIDGE per Area
65 -)))|AVBRIDGE per Area|N/A
66 66  |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|(((
67 67  SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed
68 68  Floor Hub: Y
69 69  )))|Y|N/A
70 -|BACNET Features|(((
71 -Per Area Status:
72 -Active Scene
73 -Occupied
74 -Occupancy Enabled
75 -Individual Load Level
76 -Photocell Level (per Photocell)
77 -
78 -System:
79 -Demand Response Enabled
80 -System Wide Override (Panic/Emergency)
81 -)))|See list for SHOWRUNNER™ Total Control|(((
82 -SHOWRUNNER™: See list for SHOWRUNNER™ Total Control
83 -Floor Hub: See list for ZUM-FLOOR-HUB
84 -)))|(((
85 -Per Room Status:
86 -Online
87 -On
88 -Occupied
89 -Daylighting Active
90 -Device Battery is Low
91 -Plug Loads Enabled
92 -Occupancy Sensor Enabled
93 -Current Daylight Level
94 -Active Scene
95 -\\System:
96 -Demand Response Enabled
97 -)))|N/A
52 +|BACNET Features|Area Scene, Load Control, Occupancy Status/Enable/Disable|Area Scene, Load Control, Occupancy Status/Enable/Disable|(((
53 +SHOWRUNNER™: See list to the left
54 +Floor Hub:
55 +)))| |N/A
98 98  |BACNET Settings Scope|Per Area|Per Area|(((
99 99  SHOWRUNNER™: Per Area
100 100  Floor Hub: Global
101 101  )))|Global|N/A
102 -|Crestron Fusion|Y|Y|(((
103 -SHOWRUNNER™: Y
104 -Floor Hub: N
105 -)))|N|N/A
106 -|Export to Zūm Floor Hub|Y, Licensed|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A
107 107  
108 108  ##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.##
109 -##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).##
62 +##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (Apr 2020).##