Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
To version 3.24
edited by Mark Kohlmann
on 2020/04/14 21:04
on 2020/04/14 21:04
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 9 9 ==== Feature Matrix ==== 10 10 11 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ + ZUM-FLOOR-HUB|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 11 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 12 12 |(% colspan="6" %)**Hardware Requirements** 13 13 |Requires JBOX and ZUMMESH-NETBRIDGE|Y|N|Y|Y|Y 14 14 |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A ... ... @@ -32,8 +32,18 @@ 32 32 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 33 33 |Override Occupancy Logic|Y|Y|N|N|N 34 34 |Plug Load On/Off|Y|Y|Y|Y|By Hardware 35 -|Integration with Non-Zūm Hardware|Y|Y|N|N|N 36 -|Custom Zūm Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware 35 +|Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 36 +|Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 37 +|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 38 +Floor Hub: 6-12 months|6-12 months|6-12 months 39 +|Room Organization|((( 40 +Under Development: 41 +Building/Floor/Sub-Group/Area 42 +Categorization to Filter by Different Types 43 +)))|See SHOWRUNNER™ Total Control|SHOWRUNNER™: See SHOWRUNNER™ Total Control 44 +Floor Hub: Category/Room|Category/Room|((( 45 +N/A 46 +))) 37 37 |(% colspan="6" %)**Calendar/Scheduling** 38 38 |Logic Type|Event Driven 39 39 Profile Support (Under Development)|Event Driven ... ... @@ -45,18 +45,55 @@ 45 45 |Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License 46 46 Floor Hub: N|N|N/A 47 47 |(% colspan="6" %)**Integrations** 58 +|A/V Integration: API|Y|Y|SHOWRUNNER™: Y 59 +Floor Hub: Limited|Limited|N/A 60 +|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y 61 +Floor Hub: N|N|N/A 62 +|A/V Integration: RS-232|Y|Y|((( 63 +SHOWRUNNER™: Y 64 +Floor Hub: AVBRIDGE per Area 65 +)))|AVBRIDGE per Area|N/A 48 48 |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 49 49 SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed 50 50 Floor Hub: Y 51 51 )))|Y|N/A 52 -|BACNET Features|Area Scene, Load Control, Occupancy Status/Enable/Disable|Area Scene, Load Control, Occupancy Status/Enable/Disable|((( 53 -SHOWRUNNER™: See list to the left 54 -Floor Hub: 55 -)))| |N/A 70 +|BACNET Features|((( 71 +Per Area Status: 72 +Active Scene 73 +Occupied 74 +Occupancy Enabled 75 +Individual Load Level 76 +Photocell Level (per Photocell) 77 + 78 +System: 79 +Demand Response Enabled 80 +System Wide Override (Panic/Emergency) 81 +)))|See list for SHOWRUNNER™ Total Control|((( 82 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control 83 +Floor Hub: See list for ZUM-FLOOR-HUB 84 +)))|((( 85 +Per Room Status: 86 +Online 87 +On 88 +Occupied 89 +Daylighting Active 90 +Device Battery is Low 91 +Plug Loads Enabled 92 +Occupancy Sensor Enabled 93 +Current Daylight Level 94 +Active Scene 95 +\\System: 96 +Demand Response Enabled 97 +)))|N/A 56 56 |BACNET Settings Scope|Per Area|Per Area|((( 57 57 SHOWRUNNER™: Per Area 58 58 Floor Hub: Global 59 59 )))|Global|N/A 102 +|Crestron Fusion|Y|Y|((( 103 +SHOWRUNNER™: Y 104 +Floor Hub: N 105 +)))|N|N/A 106 +|Export to Zūm Floor Hub|Y, Licensed|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A 60 60 61 61 ##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.## 62 -##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (Apr 2020).## 109 +##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).##