Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
To version 3.37
edited by Mark Kohlmann
on 2020/04/14 21:26
on 2020/04/14 21:26
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,18 +1,19 @@ 1 -Crestron Zūm Wireless is a locally integrated lighting control system with various global control options. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design. 1 +Crestron Zūm Wireless is a locally integrated lighting control system with various global control options. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design. SHOWRUNNER™ 2 2 3 3 ==== Integration Options ==== 4 4 5 -* SHOWRUNNER™ Total Control - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB. 6 -* SHOWRUNNER™ + AVBRIDGE + Serial Port - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room. Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room. 7 -* SHOWRUNNER™ + ZUM-FLOOR-HUB - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub. 5 +* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB. 6 +* **SHOWRUNNER™ + AVBRIDGE + Serial Port** - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room. Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room. 7 +* **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub. 8 8 9 9 ==== Feature Matrix ==== 10 10 11 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ + ZUM-FLOOR-HUB|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 11 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 12 12 |(% colspan="6" %)**Hardware Requirements** 13 -|Requires JBOX andZUMMESH-NETBRIDGE|Y|N|Y|Y|Y13 +|Requires JBOX with ZUMMESH-NETBRIDGE|Y|N|Y|Y|Y 14 14 |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A 15 -|Requires RS-232 Serial Port per Room|N|Y|N|N|N/A 15 +|Requires Dedicated RS-232 Serial Port per Room|N|Y|N|N|N/A 16 +|Requires 3 or 4-Series Control System|Y|Y|Y|N|N/A 16 16 |Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y 17 17 |(% colspan="6" %)**User Interfaces** 18 18 |Web Browser|((( ... ... @@ -32,28 +32,98 @@ 32 32 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 33 33 |Override Occupancy Logic|Y|Y|N|N|N 34 34 |Plug Load On/Off|Y|Y|Y|Y|By Hardware 35 -|Integration with Non-Zūm Hardware|Y|Y|N|N|N 36 -|Custom Zūm Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware 36 +|Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 37 +|Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 38 +|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 39 +Floor Hub: 6-12 months|6-12 months|6-12 months 40 +|Room Organization|((( 41 +Under Development: 42 +Building/Floor/Sub-Group/Area 43 +Categorization to Filter by Category/Tag 44 +)))|See SHOWRUNNER™ Total Control|SHOWRUNNER™: See SHOWRUNNER™ Total Control 45 +Floor Hub: Category/Room|Category/Room|((( 46 +N/A 47 +))) 48 +|Room Discovery|Automatic Discovery of Gateways and NETBRIDGES|Pre-Configured at Order|SHOWRUNNER™: Pre-Configured at Order 49 +Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of Gateways and NETBRIDGES|N/A 50 +|Firmware Updates|PUF Tool 51 +Automatic Support on Roadmap|((( 52 +PUF Tool 53 +Automatic Support on Roadmap 54 +)))|SHOWRUNNER™: PUF Tool 55 +Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A 37 37 |(% colspan="6" %)**Calendar/Scheduling** 38 38 |Logic Type|Event Driven 39 39 Profile Support (Under Development)|Event Driven 40 40 Profile Support (Under Development)|SHOWRUNNER™: Event Driven 41 41 Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A 42 -|Astronomical Clock|Y|Y|Y|Y|N/A 61 +|Astronomical Clock|Y|Y|Y, Per Category|Y, Per Category|N/A 43 43 |Holidays|Pattern|Pattern|SHOWRUNNER™: Pattern 44 44 Floor Hub: Hard Coded|Hard Coded|N/A 45 45 |Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License 46 46 Floor Hub: N|N|N/A 47 47 |(% colspan="6" %)**Integrations** 67 +|A/V Integration: API|Y|Y|SHOWRUNNER™: Y 68 +Floor Hub: Limited|Limited|N/A 69 +|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y 70 +Floor Hub: N|N|N/A 71 +|A/V Integration: RS-232|Y|Y|((( 72 +SHOWRUNNER™: Y 73 +Floor Hub: AVBRIDGE per Area 74 +)))|AVBRIDGE per Area|N/A 48 48 |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 49 49 SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed 50 50 Floor Hub: Y 51 -)))|Y| 52 -|BACNET Features|Area Scene, Load Control, Occupancy Status/Enable/Disable|Area Scene, Load Control, Occupancy Status/Enable/Disable|((( 53 -SHOWRUNNER™: See list to the left 78 +)))|Y|N/A 79 +|BACNET Features|((( 80 +Per Area Status: 81 +Active Scene 82 +Occupied 83 +Occupancy Enabled 84 +Individual Load Level 85 +Photocell Level (per Photocell) 86 +Plug Loads Enabled 54 54 55 -Floor Hub: 56 -)))| | 88 +System: 89 +Demand Response Enabled 90 +System Wide Override (Panic/Emergency) 57 57 92 +~* More Features added upon request 93 +)))|See list for SHOWRUNNER™ Total Control|((( 94 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control 95 +Floor Hub: See list for ZUM-FLOOR-HUB 96 +)))|((( 97 +Per Room Status: 98 +Online 99 +On 100 +Occupied 101 +Daylighting Active 102 +Device Battery is Low 103 +Plug Loads Enabled 104 +Occupancy Sensor Enabled 105 +Current Daylight Level 106 +Active Scene 107 +\\System: 108 +Demand Response Enabled 109 +)))|N/A 110 +|BACNET Settings Scope 111 +(What Points are Exposed)|Per Area|Per Area|((( 112 +SHOWRUNNER™: Per Area 113 +Floor Hub: Global 114 +)))|Global|N/A 115 +|BACNET Points Supported|Depends on Crestron License and Hardware|Depends on Crestron License and Hardware|SHOWRUNNER™: Depends on Crestron License and Hardware 116 +Floor Hub: 1000|1000|N/A 117 +|Crestron Fusion|Y|Y|((( 118 +SHOWRUNNER™: Y 119 +Floor Hub: N 120 +)))|N|N/A 121 +|Export to Zūm Floor Hub|Y, Licensed|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A 122 +|GLPAC|Y|Y|SHOWRUNNER™: Y 123 +Floor Hub: Via SHOWRUNNER™|N|N/A 124 +|System to System Link|Y|Y|((( 125 +SHOWRUNNER™: Y 126 +Floor Hub: N 127 +)))|N|N/A 128 + 58 58 ##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.## 59 -##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (Apr 2020).## 130 +##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).##