Summary

Details

Page properties
Content
... ... @@ -8,7 +8,7 @@
8 8  
9 9  ==== Feature Matrix ====
10 10  
11 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ + ZUM-FLOOR-HUB|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
11 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
12 12  |(% colspan="6" %)**Hardware Requirements**
13 13  |Requires JBOX and ZUMMESH-NETBRIDGE|Y|N|Y|Y|Y
14 14  |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A
... ... @@ -32,8 +32,18 @@
32 32  |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y
33 33  |Override Occupancy Logic|Y|Y|N|N|N
34 34  |Plug Load On/Off|Y|Y|Y|Y|By Hardware
35 -|Integration with Non-Zūm Hardware|Y|Y|N|N|N
36 -|Custom Zūm Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware
35 +|Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N
36 +|Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware
37 +|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive
38 +Floor Hub: 6-12 months|6-12 months|6-12 months
39 +|Room Organization|(((
40 +Under Development:
41 +Building/Floor/Sub-Group/Area
42 +Categorization to Filter by Different Types
43 +)))|See SHOWRUNNER™ Total Control|SHOWRUNNER™: See SHOWRUNNER™ Total Control
44 +Floor Hub: Category/Room|Category/Room|(((
45 +N/A
46 +)))
37 37  |(% colspan="6" %)**Calendar/Scheduling**
38 38  |Logic Type|Event Driven
39 39  Profile Support (Under Development)|Event Driven
... ... @@ -45,15 +45,55 @@
45 45  |Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License
46 46  Floor Hub: N|N|N/A
47 47  |(% colspan="6" %)**Integrations**
58 +|A/V Integration: API|Y|Y|SHOWRUNNER™: Y
59 +Floor Hub: Limited|Limited|N/A
60 +|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y
61 +Floor Hub: N|N|N/A
62 +|A/V Integration: RS-232|Y|Y|(((
63 +SHOWRUNNER™: Y
64 +Floor Hub: AVBRIDGE per Area
65 +)))|AVBRIDGE per Area|N/A
48 48  |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|(((
49 49  SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed
50 50  Floor Hub: Y
51 -)))|Y|
52 -|BACNET Features|Area Scene, Load Control, Occupancy Status/Enable/Disable|Area Scene, Load Control, Occupancy Status/Enable/Disable|(((
53 -SHOWRUNNER™: See list to the left
69 +)))|Y|N/A
70 +|BACNET Features|(((
71 +Per Area Status:
72 +Active Scene
73 +Occupied
74 +Occupancy Enabled
75 +Individual Load Level
76 +Photocell Level (per Photocell)
54 54  
55 -Floor Hub:
56 -)))| |
78 +System:
79 +Demand Response Enabled
80 +System Wide Override (Panic/Emergency)
81 +)))|See list for SHOWRUNNER™ Total Control|(((
82 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control
83 +Floor Hub: See list for ZUM-FLOOR-HUB
84 +)))|(((
85 +Per Room Status:
86 +Online
87 +On
88 +Occupied
89 +Daylighting Active
90 +Device Battery is Low
91 +Plug Loads Enabled
92 +Occupancy Sensor Enabled
93 +Current Daylight Level
94 +Active Scene
95 +\\System:
96 +Demand Response Enabled
97 +)))|N/A
98 +|BACNET Settings Scope|Per Area|Per Area|(((
99 +SHOWRUNNER™: Per Area
100 +Floor Hub: Global
101 +)))|Global|N/A
102 +|Crestron Fusion|Y|Y|(((
103 +SHOWRUNNER™: Y
104 +Floor Hub: N
105 +)))|N|N/A
106 +|Export to Zūm Floor Hub|Y, Licensed|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A
57 57  
58 58  ##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.##
59 -##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (Apr 2020).##
109 +##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).##