Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 27.1
edited by Mark Kohlmann
on 2021/04/12 17:44
on 2021/04/12 17:44
Change comment:
There is no comment for this version
To version 24.1
edited by Mark Kohlmann
on 2021/03/17 16:24
on 2021/03/17 16:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,9 +19,9 @@ 19 19 |(% colspan="6" %)**User Interfaces** 20 20 |Web Browser|((( 21 21 Crestron SmartGraphics XPanel 22 -HTML5 UI Under Development (Q 22021)22 +HTML5 UI Under Development (Q4 2020) 23 23 )))|Crestron SmartGraphics XPanel 24 -HTML5 UI Under Development (Q 22021)|SHOWRUNNER™ - Crestron SmartGraphics XPanel24 +HTML5 UI Under Development (Q4 2020)|SHOWRUNNER™ - Crestron SmartGraphics XPanel 25 25 ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 26 26 |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 27 27 |Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N ... ... @@ -33,7 +33,6 @@ 33 33 |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 34 34 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 35 35 |Override Occupancy Logic|Y|Y|N|N|N 36 -|Override|Y~*~*~*~*~*~*|N|Scene Recall only via ShowRunner|N|N/A 37 37 |Plug Load On/Off|Y|Y|Y|Y|By Hardware 38 38 |Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 39 39 |Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware ... ... @@ -135,9 +135,7 @@ 135 135 ** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 136 136 *** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 137 137 **** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time. 138 -***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 139 -****** Zūm wireless does not support a true override but ShowRunner will disable keypads and occupancy sensors. 140 -}}} 137 +***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. }}} 141 141 142 142 {{id name="caveats"/}} 143 143 ... ... @@ -149,8 +149,8 @@ 149 149 * Lower operations can turn the load off. The load will not come on with a raise. This is a firmware behavior in the Zum hardware. 150 150 * Wireless control presents some additional latency possibilities. Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load. Local operation of the Zum wireless room is not impacted. 151 151 * Real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 152 -* Keypad behaviors cannot be modified in ShowRunner.Some modifications are permitted within the Zum app.Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose.153 -* Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic externally to the linked Zum rooms.149 +* Keypad behaviors cannot be modified. Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose. 150 +* Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic. 154 154 * Off Scene cannot be saved and is always room Off 155 155 * Scenes 1 through 16 are supported and may be modified and saved. 156 156 * Scenes with fade times greater than 1 second will result in loads being commanded individual from ShowRunner and may not be in sync depending on load quantity, RF gateway load, and RF signal integrity. Zum hardware does not support a fade time as part of the Scene setting. Fade times must be commanded from ShowRunner. Scene fade times will be ignored when scenes are activated by Zum keypads or internal occupancy logic. ... ... @@ -161,10 +161,10 @@ 161 161 * Blink before timeout is not supported 162 162 * CCT control is presently not supported (ZUMMESH-JBOX-DALI support may be available in the future) 163 163 * RGB loads are not supported 164 -* Minimum/Maximum Levels are not supported when loads are being recalled locally. ShowRunner will honor them when control occurs from ShowRunner except for raise/lower which is pe rformed on hardware.161 +* Minimum/Maximum Levels are not supported when loads are being recalled locally. ShowRunner will honor them when control occurs from ShowRunner except for raise/lower which is peformed on hardware. 165 165 * Dimming curves are not supported when loads are being recalled locally. Use Zum app to adjust dimming curves if necessary. Recommended to leave ShowRunner dimming curve set to "Unaffected". 166 166 * BACNET support requires a processor hardware license and ShowRunner BACNET license. BACNET point availability can be configured per Area. 167 -* Chief Integrations recommends one 4-series (preferred) or3-series processor per building floor at a minimum.164 +* Chief Integrations recommends one 3-series processor per building floor at a minimum. 168 168 * Zummesh and infiNET EX devices are not officially supported on the same gateway, discuss with Crestron if needing both. 169 169 170 170 (% id="HTopologies" %)