Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 21.1
edited by Mark Kohlmann
on 2021/03/17 15:18
on 2021/03/17 15:18
Change comment:
There is no comment for this version
To version 19.1
edited by Mark Kohlmann
on 2021/03/17 15:08
on 2021/03/17 15:08
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -29,7 +29,7 @@ 29 29 |Scene Recall|Y ~*~*~*~*|Y ~*~*~*~*|Y|Y|Y 30 30 |Override Fade Time for Scene Recall ~*~*|Y|N|N|N|N 31 31 |Scene Save|Y ~*~*~*~*|Y ~*~*~*~*|N|N|Y 32 -|Load Control|Y ~*~** /~*~*~*~**|Y ~*~**|N|N|Y32 +|Load Control|Y ~*~**|Y ~*~**|N|N|Y 33 33 |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 34 34 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 35 35 |Override Occupancy Logic|Y|Y|N|N|N ... ... @@ -134,8 +134,6 @@ 134 134 ** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 135 135 *** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 136 136 **** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time. 137 -***** Zūm wireless real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 138 - 139 139 }}} 140 140 141 141 ==== Caveats ==== ... ... @@ -162,6 +162,7 @@ 162 162 * BACNET support requires a processor hardware license and ShowRunner BACNET license. BACNET point availability can be configured per Area. 163 163 * Chief Integrations recommends one 3-series processor per building floor at a minimum. 164 164 * Zummesh and infiNET EX devices are not officially supported on the same gateway, discuss with Crestron if needing both. 163 +* Full support has been verified against ZUM-MESHNET firmware puf v1.05.08 (NETBRIDGE Firmware v1.010.0055) 165 165 166 166 (% id="HTopologies" %) 167 167 ==== Topologies ====