Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 18.1
edited by Mark Kohlmann
on 2020/11/18 23:15
on 2020/11/18 23:15
Change comment:
There is no comment for this version
To version 19.1
edited by Mark Kohlmann
on 2021/03/17 15:08
on 2021/03/17 15:08
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -142,6 +142,25 @@ 142 142 * Raise/Lower operations from ShowRunner cannot track directly with the load response, see ~*~** above. ShowRunner will poll the NETBRIDGE for current levels ~~3 seconds after the raise/lower is stopped to obtain current load levels. 143 143 * Lower operations can turn the load off. The load will not come on with a raise. This is a firmware behavior in the Zum hardware. 144 144 * Wireless control presents some additional latency possibilities. Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load. Local operation of the Zum wireless room is not impacted. 145 +* Real time load status is not available. Any changes to loads performed using the raise/lower functions in room will not be propagated back to ShowRunner. Levels set by the daylight sensor with daylighting enabled will not be reported by ShowRunner. 146 +* Keypad behaviors cannot be modified. Custom keypads can be implemented using the AVBRIDGE connected to the system via a serial port, Zum requires an AV specific keypad for this purpose. 147 +* Zum Partition Sensors do not report back to the system and cannot be used to handle room divide/combine logic. 148 +* Off Scene cannot be saved and is always room Off 149 +* Scenes 1 through 16 are supported and may be modified and saved. 150 +* Scenes with fade times greater than 1 second will result in loads being commanded individual from ShowRunner and may not be in sync depending on load quantity, RF gateway load, and RF signal integrity. Zum hardware does not support a fade time as part of the Scene setting. Fade times must be commanded from ShowRunner. Scene fade times will be ignored when scenes are activated by Zum keypads or internal occupancy logic. 151 +* Saving scenes from ShowRunner captures the levels set in ShowRunner at the time of the save. ShowRunner will attempt to learn scenes as they are recalled. 152 +* Override/Override Level features are not supported 153 +* Load disable is not supported 154 +* After hours logic is not supported 155 +* Blink before timeout is not supported 156 +* CCT control is presently not supported (ZUMMESH-JBOX-DALI support may be available in the future) 157 +* RGB loads are not supported 158 +* Minimum/Maximum Levels are not supported when loads are being recalled locally. ShowRunner will honor them when control occurs from ShowRunner except for raise/lower which is peformed on hardware. 159 +* Dimming curves are not supported when loads are being recalled locally. Use Zum app to adjust dimming curves if necessary. Recommended to leave ShowRunner dimming curve set to "Unaffected". 160 +* BACNET support requires a processor hardware license and ShowRunner BACNET license. BACNET point availability can be configured per Area. 161 +* Chief Integrations recommends one 3-series processor per building floor at a minimum. 162 +* Zummesh and infiNET EX devices are not officially supported on the same gateway, discuss with Crestron if needing both. 163 +* Full support has been verified against ZUM-MESHNET firmware puf v1.05.08 (NETBRIDGE Firmware v1.010.0055) 145 145 146 146 (% id="HTopologies" %) 147 147 ==== Topologies ====