Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,7 +15,7 @@ 15 15 |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A 16 16 |Requires Dedicated RS-232 Serial Port per Room|N|Y|N|N|N/A 17 17 |Requires 3 or 4-Series Control System|Y|Y|Y|N|N/A 18 -| RequiresPhysical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y18 +|Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y 19 19 |(% colspan="6" %)**User Interfaces** 20 20 |Web Browser|((( 21 21 Crestron SmartGraphics XPanel ... ... @@ -26,10 +26,10 @@ 26 26 |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 27 27 |Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N 28 28 |(% colspan="6" %)**Features** 29 -|Scene Recall|Y ~*~*~*~*|Y~*~*~*~*|Y|Y|Y30 -|Override Fade Time for Scene Recall 31 -|Scene Save|Y ~*~*~*~*|Y~*~*~*~*|N|N|Y32 -|Load Control|Y ~*~**|Y~*~**|N|N|Y29 +|Scene Recall|Y|Y|Y|Y|Y 30 +|Override Fade Time for Scene Recall~*~*|Y|N|N|N|N 31 +|Scene Save|Y|Y|N|N|Y 32 +|Load Control|Y|Y|N|N|Y 33 33 |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 34 34 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 35 35 |Override Occupancy Logic|Y|Y|N|N|N ... ... @@ -126,52 +126,33 @@ 126 126 SHOWRUNNER™: Y 127 127 Floor Hub: N 128 128 )))|N|N/A 129 -|Minimum NETBRIDGE Firmware|v1.12.0130 (PUF Zum MESHNET v1.06.09)|v1.010|N/A|See Crestron|See Crestron 130 -|Minimum Gateway Firmware|v1.4469.00011|N/A|N/A|See Crestron|See Crestron 131 -|Minimum SHOWRUNNER™ Version|2.198|2.198|N/A|N/A|N/A 132 132 133 -{{{* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App. 134 -** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 135 -*** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 136 -**** Zūm wireless scenes cannot presently be read on command. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer and in ShowRunner. ShowRunner will query the NETBRIDGE after scene recall and attempt to build scene information but operations are done one at a time. 137 -}}} 130 +##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.## 131 +##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).## 138 138 139 -==== Caveats ==== 140 140 141 -* Zum Wireless has an internal rate limit that will shutdown communication if a number of commands are received in a short period of time. This can be seen when repeatedly pressing buttons on a keypad as well as repeatedly triggering actions from ShowRunner. 142 -* Raise/Lower operations from ShowRunner cannot track directly with the load response, see ~*~** above. ShowRunner will poll the NETBRIDGE for current levels ~~3 seconds after the raise/lower is stopped to obtain current load levels. 143 -* Lower operations can turn the load off. The load will not come on with a raise. This is a firmware behavior in the Zum hardware. 144 -* Wireless control presents some additional latency possibilities. Commands required to provide full functionality (load control/raise/lower) with Zum wireless are more intensive than traditional Crestron hardware and may impact performance under heavy load. Local operation of the Zum wireless room is not impacted. 145 - 146 -(% id="HTopologies" %) 147 147 ==== Topologies ==== 148 148 149 -(% class="box" %) 150 -((( 151 151 **SHOWRUNNER™ Total Control** 137 + 152 152 [[image:ZumSr\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology"]] 153 -))) 154 154 155 -(% class="box" %) 156 -((( 140 + 157 157 **SHOWRUNNER™ + AVBRIDGE + Serial Port** 142 + 158 158 [[image:ZumAvbSr\@2x.png||alt="Zum AVBRIDGE + SHOWRUNNER™ Topology"]] 159 -))) 160 160 161 -(% class="box" %) 162 -((( 145 + 163 163 **SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)** 147 + 164 164 [[image:ZumFhSr\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]] 165 -))) 166 166 167 -(% class="box" %) 168 -((( 150 + 169 169 **ZUM-FLOOR-HUB Only** 170 -[[image:ZumFh\@2x.png||alt="Zum Floor Hub Topology"]] 171 -))) 172 172 173 -(% class="box" %) 174 -((( 153 +[[image:ZumApp\@2x.png||alt="Zum App Topology"]] 154 + 155 + 175 175 **Zūm iOS/Android Setup App** 157 + 176 176 [[image:ZumApp\@2x.png||alt="Zum App Topology"]] 177 -)))