Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 16.1
edited by Mark Kohlmann
on 2020/11/09 18:16
on 2020/11/09 18:16
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,8 +1,8 @@ 1 -Crestron Zūm Wireless is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management.SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design.1 +Crestron Zūm Wireless is a locally integrated lighting control system with various global control options. SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design. 2 2 3 3 ==== Integration Options ==== 4 4 5 -* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design.5 +* **SHOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB. 6 6 * **SHOWRUNNER™ + AVBRIDGE + Serial Port** - Provides scene setting and load control via a dedicated AVBRIDGE in each Zūm room. Requires a dedicated serial port (C2N-IO/CEN-IO-COM2/etc) and a dedicated ZUMMESH-AVBRIDGE per room. 7 7 * **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub. 8 8 ... ... @@ -15,7 +15,7 @@ 15 15 |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A 16 16 |Requires Dedicated RS-232 Serial Port per Room|N|Y|N|N|N/A 17 17 |Requires 3 or 4-Series Control System|Y|Y|Y|N|N/A 18 -| RequiresPhysical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y18 +|Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y 19 19 |(% colspan="6" %)**User Interfaces** 20 20 |Web Browser|((( 21 21 Crestron SmartGraphics XPanel ... ... @@ -26,10 +26,10 @@ 26 26 |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 27 27 |Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N 28 28 |(% colspan="6" %)**Features** 29 -|Scene Recall|Y ~*~*~*~*|Y~*~*~*~*|Y|Y|Y30 -|Override Fade Time for Scene Recall 31 -|Scene Save|Y ~*~*~*~*|Y~*~*~*~*|N|N|Y32 -|Load Control|Y ~*~**|Y~*~**|N|N|Y29 +|Scene Recall|Y|Y|Y|Y|Y 30 +|Override Fade Time for Scene Recall~*~*|Y|N|N|N|N 31 +|Scene Save|Y|Y|N|N|Y 32 +|Load Control|Y|Y|N|N|Y 33 33 |Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 34 34 |Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 35 35 |Override Occupancy Logic|Y|Y|N|N|N ... ... @@ -127,42 +127,32 @@ 127 127 Floor Hub: N 128 128 )))|N|N/A 129 129 130 -{{{* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App. 131 -** Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020). 132 -*** Zūm wireless does not support direct coupling of fade times and the behavior is different internally within the dimmer versus other Crestron products. Raise/Lower level accuracy is not guaranteed. For best performance when settings scenes, set the slider manually which will send exact levels to the dimmer. 133 -**** Zūm wireless scenes cannot presently be read. Scenes should be created and saved from SHOWRUNNER™ directly. Saved scenes are stored directly on the Zūm wireless dimmer. 134 -}}} 130 +##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.## 131 +##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).## 135 135 136 136 137 -(% id="HTopologies" %) 138 138 ==== Topologies ==== 139 139 140 -(% class="box" %) 141 -((( 142 142 **SHOWRUNNER™ Total Control** 137 + 143 143 [[image:ZumSr\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology"]] 144 -))) 145 145 146 -(% class="box" %) 147 -((( 140 + 148 148 **SHOWRUNNER™ + AVBRIDGE + Serial Port** 142 + 149 149 [[image:ZumAvbSr\@2x.png||alt="Zum AVBRIDGE + SHOWRUNNER™ Topology"]] 150 -))) 151 151 152 -(% class="box" %) 153 -((( 145 + 154 154 **SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)** 147 + 155 155 [[image:ZumFhSr\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]] 156 -))) 157 157 158 -(% class="box" %) 159 -((( 150 + 160 160 **ZUM-FLOOR-HUB Only** 161 -[[image:ZumFh\@2x.png||alt="Zum Floor Hub Topology"]] 162 -))) 163 163 164 -(% class="box" %) 165 -((( 153 +[[image:ZumApp\@2x.png||alt="Zum App Topology"]] 154 + 155 + 166 166 **Zūm iOS/Android Setup App** 157 + 167 167 [[image:ZumApp\@2x.png||alt="Zum App Topology"]] 168 -)))