Changes for page Crestron Zūm Wireless
Last modified by Scott Kohlmann on 2023/04/20 22:28
From version 1.1
edited by Mark Kohlmann
on 2020/04/14 17:12
on 2020/04/14 17:12
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,20 +8,102 @@ 8 8 9 9 ==== Feature Matrix ==== 10 10 11 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ + ZUM-FLOOR-HUB|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 12 -|**Hardware Requirements** |-|-|-|-|-11 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 12 +|(% colspan="6" %)**Hardware Requirements** 13 13 |Requires JBOX and ZUMMESH-NETBRIDGE|Y|N|Y|Y|Y 14 14 |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A 15 15 |Requires RS-232 Serial Port per Room|N|Y|N|N|N/A 16 -| | | | | | 17 -|Web Based GUI|Crestron SmartGraphics XPanel (HTML5 UI is under development)| | | | 18 -| | | | | | 19 -| | | | | | 20 -| | | | | | 21 -| | | | | | 22 -| | | | | | 23 -| | | | | | 24 -| | | | | | 25 -| | | | | | 16 +|Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y 17 +|(% colspan="6" %)**User Interfaces** 18 +|Web Browser|((( 19 +Crestron SmartGraphics XPanel 20 +HTML5 UI Under Development (Q4 2020) 21 +)))|Crestron SmartGraphics XPanel 22 +HTML5 UI Under Development (Q4 2020)|SHOWRUNNER™ - Crestron SmartGraphics XPanel 23 +ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 24 +|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 25 +|Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N 26 +|(% colspan="6" %)**Features** 27 +|Scene Recall|Y|Y|Y|Y|Y 28 +|Override Fade Time for Scene Recall~*~*|Y|N|N|N|N 29 +|Scene Save|Y|Y|N|N|Y 30 +|Load Control|Y|Y|N|N|Y 31 +|Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N 32 +|Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y 33 +|Override Occupancy Logic|Y|Y|N|N|N 34 +|Plug Load On/Off|Y|Y|Y|Y|By Hardware 35 +|Integration with Non-Zūm Crestron Hardware|Y|Y|N|N|N 36 +|Custom Zūm Keypad Programming|N|Y, Zūm AV Keypad Only|N|N|Y, within the limits of the hardware 37 +|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive 38 +Floor Hub: 6-12 months|6-12 months|6-12 months 39 +|Room Organization|((( 40 +Under Development: 41 +Building/Floor/Sub-Group/Area 42 +Categorization to Filter by Different Types 43 +)))|See SHOWRUNNER™ Total Control|SHOWRUNNER™: See SHOWRUNNER™ Total Control 44 +Floor Hub: Category/Room|Category/Room|((( 45 +N/A 46 +))) 47 +|(% colspan="6" %)**Calendar/Scheduling** 48 +|Logic Type|Event Driven 49 +Profile Support (Under Development)|Event Driven 50 +Profile Support (Under Development)|SHOWRUNNER™: Event Driven 51 +Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A 52 +|Astronomical Clock|Y|Y|Y|Y|N/A 53 +|Holidays|Pattern|Pattern|SHOWRUNNER™: Pattern 54 +Floor Hub: Hard Coded|Hard Coded|N/A 55 +|Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License 56 +Floor Hub: N|N|N/A 57 +|(% colspan="6" %)**Integrations** 58 +|A/V Integration: API|Y|Y|SHOWRUNNER™: Y 59 +Floor Hub: Limited|Limited|N/A 60 +|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y 61 +Floor Hub: N|N|N/A 62 +|A/V Integration: RS-232|Y|Y|((( 63 +SHOWRUNNER™: Y 64 +Floor Hub: AVBRIDGE per Area 65 +)))|AVBRIDGE per Area|N/A 66 +|BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 67 +SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed 68 +Floor Hub: Y 69 +)))|Y|N/A 70 +|BACNET Features|((( 71 +Per Area Status: 72 +Active Scene 73 +Occupied 74 +Occupancy Enabled 75 +Individual Load Level 76 +Photocell Level (per Photocell) 26 26 27 -##* Zūm Setup App works as long as the NETBRIDGE is physical near the iOS/Android device running the Zūm Setup App.## 78 +System: 79 +Demand Response Enabled 80 +System Wide Override (Panic/Emergency) 81 +)))|See list for SHOWRUNNER™ Total Control|((( 82 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control 83 +Floor Hub: See list for ZUM-FLOOR-HUB 84 +)))|((( 85 +Per Room Status: 86 +Online 87 +On 88 +Occupied 89 +Daylighting Active 90 +Device Battery is Low 91 +Plug Loads Enabled 92 +Occupancy Sensor Enabled 93 +Current Daylight Level 94 +Active Scene 95 +\\System: 96 +Demand Response Enabled 97 +)))|N/A 98 +|BACNET Settings Scope|Per Area|Per Area|((( 99 +SHOWRUNNER™: Per Area 100 +Floor Hub: Global 101 +)))|Global|N/A 102 +|Crestron Fusion|Y|Y|((( 103 +SHOWRUNNER™: Y 104 +Floor Hub: N 105 +)))|N|N/A 106 +|Export to Zūm Floor Hub|Y, Licensed|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A 107 + 108 +##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.## 109 +##~*~* Fade time is automatically applied if scene is set longer than 1 second. Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (as of April 2020).##