Changes for page Crestron Zūm Wireless

Last modified by Scott Kohlmann on 2023/04/20 22:28

From version 1.1
edited by Mark Kohlmann
on 2020/04/14 17:12
Change comment: There is no comment for this version
To version 3.20
edited by Mark Kohlmann
on 2020/04/14 20:59
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -9,19 +9,93 @@
9 9  ==== Feature Matrix ====
10 10  
11 11  |=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ + AVBRIDGE + Serial Port|=SHOWRUNNER™ + ZUM-FLOOR-HUB|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
12 -|**Hardware Requirements**|-|-|-|-|-
12 +|(% colspan="6" %)**Hardware Requirements**
13 13  |Requires JBOX and ZUMMESH-NETBRIDGE|Y|N|Y|Y|Y
14 14  |Requires ZUMMESH-GATEWAY|Y|N|Y|Y|N/A
15 15  |Requires RS-232 Serial Port per Room|N|Y|N|N|N/A
16 +|Physical Presence in Room to Change Scenes|N|N|Y, via Zūm Setup App|Y, via Zūm Setup App|Y
17 +|(% colspan="6" %)**User Interfaces**
18 +|Web Browser|(((
19 +Crestron SmartGraphics XPanel
20 +HTML5 UI Under Development (Q4 2020)
21 +)))|Crestron SmartGraphics XPanel
22 +HTML5 UI Under Development (Q4 2020)|SHOWRUNNER™ - Crestron SmartGraphics XPanel
23 +ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N
24 +|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
25 +|Touchscreens (Crestron TSW series)|Y|Y|Y, Limited Features for Zūm Rooms|N|N
26 +|(% colspan="6" %)**Features**
27 +|Scene Recall|Y|Y|Y|Y|Y
28 +|Override Fade Time for Scene Recall~*~*|Y|N|N|N|N
29 +|Scene Save|Y|Y|N|N|Y
30 +|Load Control|Y|Y|N|N|Y
31 +|Demand Response|Y|N|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N
32 +|Enable/Disable Occupancy|Y|Y|Y, from Floor Hub|Y|Y
33 +|Override Occupancy Logic|Y|Y|N|N|N
34 +|Plug Load On/Off|Y|Y|Y|Y|By Hardware
35 +|Integration with Non-Zūm Hardware|Y|Y|N|N|N
36 +|Custom Zūm Keypad Programming|N|Y, AV Keypad Only|N|N|Y, within the limits of the hardware
37 +|New Feature Release Cycle|Aggressive|Aggressive|SHOWRUNNER™: Aggressive
38 +Floor Hub: 6-12 months|6-12 months|6-12 months
39 +|(% colspan="6" %)**Calendar/Scheduling**
40 +|Logic Type|Event Driven
41 +Profile Support (Under Development)|Event Driven
42 +Profile Support (Under Development)|SHOWRUNNER™: Event Driven
43 +Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A
44 +|Astronomical Clock|Y|Y|Y|Y|N/A
45 +|Holidays|Pattern|Pattern|SHOWRUNNER™: Pattern
46 +Floor Hub: Hard Coded|Hard Coded|N/A
47 +|Custom Patterns|Y, Advanced Scheduler License|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License
48 +Floor Hub: N|N|N/A
49 +|(% colspan="6" %)**Integrations**
50 +|A/V Integration: API|Y|Y|SHOWRUNNER™: Y
51 +Floor Hub: Limited|Limited|N/A
52 +|A/V Integration: Crestron EISC|Y|Y|SHOWRUNNER™: Y
53 +Floor Hub: N|N|N/A
54 +|A/V Integration: RS-232|Y|Y|(((
55 +SHOWRUNNER™: Y
56 +Floor Hub: AVBRIDGE per Area
57 +)))|AVBRIDGE per Area|N/A
58 +|BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y, SHOWRUNNER™ and Crestron Licenses Needed|(((
59 +SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed
60 +Floor Hub: Y
61 +)))|Y|N/A
62 +|BACNET Features|(((
63 +Per Area Status:
64 +Active Scene
65 +Occupied
66 +Occupancy Enabled
67 +Individual Load Level
68 +Photocell Level (per Photocell)
69 +
70 +System:
71 +Demand Response Enabled
72 +System Wide Override (Panic/Emergency)
73 +)))|See list for SHOWRUNNER™ Total Control|(((
74 +SHOWRUNNER™: See list for SHOWRUNNER™ Total Control
75 +Floor Hub: See list for ZUM-FLOOR-HUB
76 +)))|(((
77 +Per Room Status:
78 +Online
79 +On
80 +Occupied
81 +Daylighting Active
82 +Device Battery is Low
83 +Plug Loads Enabled
84 +Occupancy Sensor Enabled
85 +Current Daylight Level
86 +Active Scene
87 +\\System:
88 +Demand Response Enabled
89 +)))|N/A
90 +|BACNET Settings Scope|Per Area|Per Area|(((
91 +SHOWRUNNER™: Per Area
92 +Floor Hub: Global
93 +)))|Global|N/A
94 +|Crestron Fusion|Y|Y|(((
95 +SHOWRUNNER™: Y
96 +Floor Hub: N
97 +)))|N|N/A
16 16  | | | | | |
17 -|Web Based GUI|Crestron SmartGraphics XPanel (HTML5 UI is under development)| | | |
18 -| | | | | |
19 -| | | | | |
20 -| | | | | |
21 -| | | | | |
22 -| | | | | |
23 -| | | | | |
24 -| | | | | |
25 -| | | | | |
26 26  
27 -##* Zūm Setup App works as long as the NETBRIDGE is physical near the iOS/Android device running the Zūm Setup App.##
100 +##* Zūm Setup App works as long as the NETBRIDGE is physically near the iOS/Android device running the Zūm Setup App.##
101 +##~*~* Fade time is automatically applied if scene is set longer than 1 second.  Must be triggered from SHOWRUNNER™, cannot be triggered from Zūm keypad with current firmware (Apr 2020).##