Changes for page ShowRunnerCLC™ Keypad Types
Last modified by Alexander Mott on 2024/05/13 15:02
From version 142.1
edited by Alexander Mott
on 2023/02/07 19:24
on 2023/02/07 19:24
Change comment:
Uploaded new attachment "showrunnerKeypadStyles.pdf", version 1.1
To version 143.1
edited by Alexander Mott
on 2023/02/07 19:54
on 2023/02/07 19:54
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,7 +2,6 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 - 6 6 The showrunner™ program includes several pre-built keypad types suitable for a wide variety of applications. In addition to standard keypad types, showrunner™ supports custom "X-Type" keypad configurations. Custom keypads can be configured from the showrunnerHUB™ Web Interface, or they can be manually added to the config and enabled using the XPanel Touchscreen interface. 7 7 8 8 = Cameo Keypads = ... ... @@ -677,6 +677,8 @@ 677 677 678 678 The showrunner™ X-Type keypad is a customizable keypad type available for Cameo, Horizon, GLPPA-KP, and Zūm Wired keypads. See[[ this document>>attach:showrunnerKeypadStyles.pdf]] for a list of possible keypad layouts for all keypad types. Instructions for configuring X-Type keypads from the showrunnerHUB™ UI are available [[here>>https://wiki.chiefintegrations.com/download/SHOWRUNNER%E2%84%A2%20Setup%20Guide/showrunnerHUB%E2%84%A2/Keypad%20Configuration/WebHome/CI%20Keypad%20Editor%20UI%20Guide.pdf?rev=1.2]]. 679 679 679 +Note that generally, "Press" actions will always be executed, while "Tap" actions will not execute if there is a subsequent Double-Tap or Hold. 680 + 680 680 The table below is a comprehensive list of actions which can be used to manually configure X-Type keypads from the SrConfig.json file. The table was generated using showrunner™ v3.019, but can be viewed for any version of showrunner™ by connecting to a processor running the desired version of showrunner™ and running the command: ##sr sh ac## 681 681 682 682 Note that actions with "None" listed under "Triggers" are read-only and are only able to be used for keypad or keyswitch feedback. ... ... @@ -833,8 +833,8 @@ 833 833 |Occupancy|Disable|Disables the occupancy sensor|n/a|False|Digital, Analog|n/a 834 834 |Occupancy|Enable|Enables the occupancy sensor|n/a|False|Digital, Analog|n/a 835 835 |Occupancy|Occupied|Reports the occupied status of an occupancy sensor|n/a|False|None|n/a 836 - 837 837 ))) 838 + 838 838 (% class="col-xs-12 col-sm-4" %) 839 839 ((( 840 840 {{box title="**CONTENTS**"}} ... ... @@ -841,3 +841,4 @@ 841 841 {{toc/}} 842 842 {{/box}} 843 843 ))) 845 +)))