... ... @@ -9,10 +9,10 @@
9 9  
10 10  ==== Key Capabilities ====
11 11  
12 -* Configuration driven with runtime configuration support enables rapid commissioning of commercial lighting systems
12 +* Configuration driven with runtime adaptability enables rapid commissioning of commercial lighting systems
13 13  * Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements
14 -* Large native hardware support with the option to extend support to new hardware quickly and easily
15 -* Touchpanel and web based UIs cover users needs
14 +* Large native hardware support with the ability to extend support to new hardware quickly and easily
15 +* Touchpanel and web based UIs cover users' needs
16 16  * Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers
17 17  * Floorplans with pinch, zoom, and insight!
18 18  * Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes
... ... @@ -25,7 +25,7 @@
25 25  * User configurable scene name, fade time, and load include by scene
26 26  * Individual scenes may be locked to prevent changing their settings
27 27  * Individual load control within an area
28 -* Select area from touchpanel, areas can be restricted by panel
28 +* Area selection from touchpanel, areas can be restricted by panel
29 29  * RGB controls for applicable fixtures, saved per scene
30 30  * Configurable Load Grouping for load consolidation including linked/group area loads
31 31  * Dynamic White/Circadian Rhythm CCT Control
... ... @@ -85,7 +85,7 @@
85 85  * Demand Response Level
86 86  * Enable/Disable/Override states
87 87  * Option to ignore long fade times if the loads is off
88 -* Option recall last on level
88 +* Option to recall last on level
89 89  * Individual daylight harvesting settings, enabled/disabled by scene
90 90  ** Open/closed loop
91 91  ** Min/Max levels
... ... @@ -107,7 +107,7 @@
107 107  
108 108  ==== Scheduling Features ====
109 109  
110 -* Algorithm based scheduling engine ensures predictable operation year after year with no need to specifically specify each day
110 +* Algorithm based scheduling engine ensures predictable operation year after year with no need to define a system wide schedule per-day
111 111  * Area and/or Tag based schedules
112 112  * Individual global events or grouped events
113 113  * showrunner™ HUB UI Features
... ... @@ -234,6 +234,7 @@
234 234  ** User configurable Auto (use sensor) with manual override for Combined and Divided
235 235  ** Filtering to ignore noisy partition sensors
236 236  ** Change count and last change recorded help troubleshoot
237 +** Hardware not required, may be setup as a virtual sensor
237 237  * Photocell
238 238  ** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior)
239 239  ** Configurable coefficient
... ... @@ -387,7 +387,7 @@
387 387  *** Global Actions - Add/Delete/Configure
388 388  *** Integrations - Manage integrations with other showrunner™ systems
389 389  *** Keypad Configuration - Configure keypads
390 -*** Maps - Add floorplan images
391 +*** Maps - Add/Manage floorplan images
391 391  *** Network - DHCP Server (for processors without routers only)
392 392  *** System Settings - Manage various system settings
393 393  *** Tags - Manage tags and association of tags with areas