Changes for page Features

Last modified by Scott Kohlmann on 2023/04/21 15:15

From version 8.1
edited by Mark Kohlmann
on 2022/10/17 20:43
Change comment: There is no comment for this version
To version 5.2
edited by Mark Kohlmann
on 2022/10/16 17:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,22 +1,5 @@
1 -showrunner™ is a commercial lighting control and lighting management system.  showrunner™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.  Hardware support is extensive and growing all the time.  This document is not a complete feature list and Chief Integrations reserves the right to make modifications at any time.
1 +showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.  Hardware support is extensive and growing all the time.
2 2  
3 -{{box cssClass="floatinginfobox"}}
4 -(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %)
5 -**CONTENTS**
6 -
7 -{{toc start="4"/}}
8 -{{/box}}
9 -
10 -==== Key Capabilities ====
11 -
12 -* Configuration driven with runtime adaptability enables rapid commissioning of commercial lighting systems
13 -* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements
14 -* Large native hardware support with the ability to extend support to new hardware quickly and easily
15 -* Touchpanel and web based UIs cover users' needs
16 -* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers
17 -* Floorplans with pinch, zoom, and insight!
18 -* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes
19 -
20 20  ==== Area Features ====
21 21  
22 22  * Lighting Loads
... ... @@ -25,7 +25,7 @@
25 25  * User configurable scene name, fade time, and load include by scene
26 26  * Individual scenes may be locked to prevent changing their settings
27 27  * Individual load control within an area
28 -* Area selection from touchpanel, areas can be restricted by panel
11 +* Select area from touchpanel, areas can be restricted by panel
29 29  * RGB controls for applicable fixtures, saved per scene
30 30  * Configurable Load Grouping for load consolidation including linked/group area loads
31 31  * Dynamic White/Circadian Rhythm CCT Control
... ... @@ -85,7 +85,7 @@
85 85  * Demand Response Level
86 86  * Enable/Disable/Override states
87 87  * Option to ignore long fade times if the loads is off
88 -* Option to recall last on level
71 +* Option recall last on level
89 89  * Individual daylight harvesting settings, enabled/disabled by scene
90 90  ** Open/closed loop
91 91  ** Min/Max levels
... ... @@ -107,7 +107,7 @@
107 107  
108 108  ==== Scheduling Features ====
109 109  
110 -* Algorithm based scheduling engine ensures predictable operation year after year with no need to define a system wide schedule per-day
93 +* Algorithm based scheduling engine ensures predictable operation year after year with no need to specifically specify each day
111 111  * Area and/or Tag based schedules
112 112  * Individual global events or grouped events
113 113  * showrunner™ HUB UI Features
... ... @@ -211,7 +211,6 @@
211 211  *** Scene Recall for Active and Inactive States
212 212  *** Demand Response
213 213  *** Actions for Active and Inactive States
214 -** Commonly used for FACP, override, demand response, and panic inputs
215 215  * Occupancy Sensors:
216 216  ** Occupancy configuration for CN and ZUMLINK occupancy sensors
217 217  ** ​3rd Party and Non-System occupancy sensor support
... ... @@ -234,7 +234,6 @@
234 234  ** User configurable Auto (use sensor) with manual override for Combined and Divided
235 235  ** Filtering to ignore noisy partition sensors
236 236  ** Change count and last change recorded help troubleshoot
237 -** Hardware not required, may be setup as a virtual sensor
238 238  * Photocell
239 239  ** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior)
240 240  ** Configurable coefficient
... ... @@ -241,25 +241,13 @@
241 241  ** Configurable thresholds
242 242  ** Assignable to individual loads for daylight harvesting
243 243  * Serial Interface
244 -** RS-232/422/484 depending on hardware
225 +** RS-232/422/484
245 245  ** Configurable Baud Rate and Com settings
246 -** Simple ASCII API for controlling/monitoring
227 +** Simple ASCII API for controlling/montioring
247 247  ** Areas/Loads/Occupancy/Partition/Shades supported
248 248  * Shades
249 249  ** Support for Crestron shades/drapes
250 250  ** Support for many 3rd party shade and drape systems
251 -* Zum Wired
252 -** Edge logic operation in Zum App mode
253 -*** Override occupancy logic and use showrunner™ logic
254 -** Central logic in CNET mode
255 -** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes
256 -* Zum Wireless
257 -** Override keypad buttons (except buttons 5-6)
258 -** Edge logic operation
259 -** Override occupancy behavior with showrunner™ logic
260 -** Direct load control
261 -** Scene save
262 -* Support for configuring hardware symbol properties on Crestron hardware
263 263  
264 264  ==== Energy Efficiency ====
265 265  
... ... @@ -280,36 +280,20 @@
280 280  ** HTTPS enforced
281 281  ** Auto session timeout
282 282  ** Login via username/password or PIN code
283 -** Support for Processor and internal user database with configurable priority or specify one exclusively
252 +** Support for Processor or internal user database
284 284  ** Best practices for password handling
285 285  * API using AWSv4 scheme for authentication per request for maximum security
286 -* Encrypted storage of all credentials and keys
287 287  
288 -==== General Features ====
256 +==== System Features ====
289 289  
290 290  * User configurable time zone, location, and current time
291 291  * Addressing and Verification of Cresnet devices by serial number
292 292  * Cresnet Device Serial Number capture
261 +* Configurable Global Actions with touchpanel trigger
293 293  * Extensive console command interface (CLI)
294 -* Simulate sensor and keypad inputs to test without hardware
295 -* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 
296 -Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only.
297 297  
298 -==== Diagnostics ====
264 +Event Log / Auditing
299 299  
300 -* Provides diagnostic data when supported by hardware
301 -* Diagnostics available from load controllers all the way up to Cresnet bridges
302 -* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only
303 -
304 -==== Discovery ====
305 -
306 -* Discover and automatically define Zum Wired hardware
307 -* Discover and automatically define Zum Wireless hardware
308 -* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number
309 -* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming
310 -
311 -==== Event Log ====
312 -
313 313  * Central logging mechanism
314 314  * Messages time stamped
315 315  * CSV format
... ... @@ -336,13 +336,13 @@
336 336  ** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem
337 337  ** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]]
338 338  * Global Actions
339 -** Allow manual or input triggered operations against the system
292 +** Allow minimal or input triggered operations against the system
340 340  ** Can be custom programmed at runtime
341 341  
342 342  ==== User Interfaces ====
343 343  
344 344  * showrunner™ HUB
345 -** Web based, touch and mouse friendly design
298 +** Web based
346 346  ** Runs directly on the processor or VC-4 instance
347 347  ** HTTPS required
348 348  ** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience
... ... @@ -388,55 +388,17 @@
388 388  *** Global Actions - Add/Delete/Configure
389 389  *** Integrations - Manage integrations with other showrunner™ systems
390 390  *** Keypad Configuration - Configure keypads
391 -*** Maps - Add/Manage floorplan images
344 +*** Maps - Add floorplan images
392 392  *** Network - DHCP Server (for processors without routers only)
393 393  *** System Settings - Manage various system settings
394 394  *** Tags - Manage tags and association of tags with areas
395 395  *** User Management - Manage users/groups/API users
396 396  * Crestron TS/TSWs and Crestron App (iPad/iPhone/Android)
397 -** Area Control Screen
398 -*** Select Area (Can be disabled or restricted)
399 -*** Divide/Combine status, if divisible
400 -*** Occupancy/vacancy status, if has an occupancy sensor
401 -*** Individual load controls
402 -*** Dynamic white color temperature control, if supported
403 -*** RGB color picker, if load supported
404 -*** Scenes, up to 20, save with press and hold
405 -*** Master Raise/Lower
406 -*** Global Actions, if defined, can be hidden
407 -*** HVAC controls, if supported
408 -*** Shade controls, if supported
409 -*** Passcode protected, if enabled
410 -** Setup Screen
411 -*** Passcode protected, if enabled
412 -*** Area Configuration
413 -**** Area List
414 -**** Area Name, editable
415 -**** Load Configuration - Configure load control type and labeling, test fixture operation
416 -**** Occupancy Setup - Configure area occupancy behavior and occupancy settings
417 -**** Daylight Harvesting - Configure daylight harvesting settings per load/scene
418 -**** Scene Setup - Configure and add/delete scenes
419 -**** Properties - Configure area behavior settings
420 -**** Add/Delete areas
421 -*** Area Layout - Configure partition sensors and area assignments to partition sensors
422 -*** Crestron Integration - Configure EISCs
423 -*** Device Addressing - Address and verify Cresnet devices
424 -*** Keypad Configuration - Configure keypad type, area assignment, and enable status
425 -*** Load Hardware - Configure loads and load controllers
426 -*** Location and System Clock - View/Set system clock, site lat/lon, and timezone
427 -*** Occupancy Assignment - Assign occupancy sensors to loads/areas
428 -*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events)
429 -*** Security Settings - Enable/Disable/Change PIN codes
430 -*** Zum Integration - Configure export to Zum Floor Hub
431 -*** Help Screen - Support contact information, showrunner version list, and license status
432 -** Custom Logo option for splash screen
433 -** Optional floor plan area selection, zoom/pan are NOT supported, static image only
434 -** Optional partition control on floor plan screen
435 435  
436 436  === Integrations ===
437 437  
438 -* AV Integration protocol via serial port, simple ASCII protocol with feedback
439 -* BACnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron)
353 +* AV Integration protocol via serial port
354 +* BACNnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron)
440 440  ** Global
441 441  *** Override
442 442  *** Demand Response
... ... @@ -458,12 +458,12 @@
458 458  **** Scenes
459 459  **** Occupied
460 460  **** Occupancy Sensor Enable
461 -* Crestron Fusion EM (Licensed Feature)
376 +* Crestron Fusion (Licensed Feature)
462 462  ** Scenes, Recall and Save
463 463  ** Load Control
464 464  ** Occupancy Status
465 465  ** Photocell
466 -* e-DMX Receiver
381 +* E-DMX Receiver
467 467  ** SACN and/or Art-Net
468 468  ** Enable/Disable control for loads using e-DMX channel value
469 469  ** Map DMX to showrunner loads
... ... @@ -472,7 +472,7 @@
472 472  ** Configurable rooms to export, change at runtime
473 473  ** Changes generate new RSD file at runtime that may be provided to the AV programmer
474 474  * HTTP REST API w/ Authorization
475 -* Lightweight API provides real-time control/feedback using CoAP
390 +* Lightweight API provides real-time control/feedback of hardware using CoAP
476 476  * TCP Interface using simple ASCII commands, subscriptions supported
477 477  * UDP Receiver using simple ASCII commands
478 478  * Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature)
... ... @@ -487,7 +487,7 @@
487 487  ** Partition Sensors (including setup for Cresnet sensors)
488 488  ** Photocells
489 489  
490 -==== Reporting ====
405 +=== Reporting ===
491 491  
492 492  ShowRunner provides a website via the processor's internal webserver with the following reports.  All data is live at the time of the generation of the report.
493 493