Changes for page Features
Last modified by Scott Kohlmann on 2023/04/21 15:15
From version 7.1
edited by Mark Kohlmann
on 2022/10/17 19:19
on 2022/10/17 19:19
Change comment:
There is no comment for this version
To version 4.1
edited by Mark Kohlmann
on 2020/09/02 21:04
on 2020/09/02 21:04
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,29 +1,10 @@ 1 - showrunner™is a commercial lighting controland lighting managementsystem.showrunner™ containsalarge number of features focused on the needs of the commercial lightingand hospitalitymarkets and is adaptable to the residential market.Hardware support is extensive and growing all the time. This document is not a complete feature list and Chief Integrations reserves the right to make modifications at any time.1 +SHOWRUNNER™ has a large number of features focused on the needs of the commercial lighting market. 2 2 3 -{{box cssClass="floatinginfobox"}} 4 -(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %) 5 -**CONTENTS** 3 +=== Features === 6 6 7 -{{toc start="4"/}} 8 -{{/box}} 9 - 10 -==== Key Capabilities ==== 11 - 12 -* Configuration driven with runtime configuration support enables rapid commissioning of commercial lighting systems 13 -* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements 14 -* Large native hardware support with the option to extend support to new hardware quickly and easily 15 -* Touchpanel and web based UIs cover users needs 16 -* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers 17 -* Floorplans with pinch, zoom, and insight! 18 -* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes 19 - 20 -==== Area Features ==== 21 - 22 -* Lighting Loads 23 -* Scene recall 24 -* Master raise/lower 25 -* User configurable scene name, fade time, and load include by scene 26 -* Individual scenes may be locked to prevent changing their settings 5 +* Lighting Controls grouped into Areas 6 +* Scene recall and master raise/lower by area 7 +* User configurable scene name, fade time, and load include by area 27 27 * Individual load control within an area 28 28 * Select area from touchpanel, areas can be restricted by panel 29 29 * RGB controls for applicable fixtures, saved per scene ... ... @@ -32,451 +32,80 @@ 32 32 ** CCT Control per area for applicable fixtures 33 33 ** Global schedule for CCT, astronomical and/or fixed schedules 34 34 ** Manual CCT override per area 35 -* Demand Response with ability to exclude area from Demand Response event 36 -* Configurable load grouping allows aggregation of loads to a single slider per group, can include linked areas 37 -* HVAC Control 38 -* Shades 39 -* Occupancy Features 40 -** Occupancy Modes 41 -*** Occupancy 42 -*** Vacancy 43 -*** Disabled 44 -*** Use Hardware Logic (if supported by edge controller) 45 -** Extend occupancy timeout by user specified seconds, can be scheduled 46 -** Configurable occupied and vacant scenes, scheduled 47 -** Configurable grace occupancy support without needing support in hardware 48 -* After Hours support for automatic shutoff after configurable timeout w/ alerting 49 -* Parent Area feature allows one area to trickle down scene recall and raise/lower (if enabled) 50 -* Last Scene Recall timestamp and triggering action recorded 51 -* Organized in a node tree with multiple depths 52 - 53 -==== Load Features ==== 54 - 55 -* Dynamically assigned/unassigned at runtime to areas 56 -* Supported load types 57 -** Single Channel 58 -** Dynamic White/CCT 59 -*** Warm/Cool 60 -*** Intensity/CCT 61 -*** DALI Type 8 62 -*** Pharos Dynamic White 63 -** RGB/W/A 64 -*** Color Picker 65 -*** W/A channels can be controlled individually or mixed (Pharos) 66 -* Supported load behaviors 67 -** Dimmable 68 -** Switched 69 -** Plug Load 70 -* Dimming Curves 71 -** Unaffected 72 -** Linear 73 -** Linear No Zero Pass (support for EM lights that are not allowed to turn off i.e. Chicago 10%) 74 -** Logarithmic 75 -** Non Dim 76 -** S Curve 77 -** Soft Linear 78 -** Square 79 -** Always On 80 -** Inverse Log 81 -** Custom based on input output ranges 82 -* Min/Mix Trim, performed in hardware if supported 83 -* Override Level, performed in hardware if supported 84 -* Unoccupied Level 85 -* Demand Response Level 86 -* Enable/Disable/Override states 87 -* Option to ignore long fade times if the loads is off 88 -* Option recall last on level 89 -* Individual daylight harvesting settings, enabled/disabled by scene 90 -** Open/closed loop 91 -** Min/Max levels 92 -** Sensitivity 93 -** Fade time 94 -* Loads may track other loads 95 -* Remap channels for unusual fixture channel mappings 96 -* Raise/lower, performed with software fade engine if not supported by hardware 97 -* Dynamic White/Circadian Rhythm CCT 98 98 ** Custom CCT curves per load or default algorithm 99 99 ** Min/Max CCT per load 100 100 ** Support for Warm/Cool or Intensity/CCT fixture types 101 101 ** Configurable automatic fixture shut off if outside CCT range 102 -** Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 103 -* Load flashing for identification 104 -* Verified timestamp option 105 -* DALI (DIN-DALI-2/ZUMNET-JBOX-DALI Legacy mode) 106 -** Addressing/Grouping/Driver Replacement for DALI. DALI groups are referenced by their controlled load simplifying addressing and replacement procedures. 107 - 108 -==== Scheduling Features ==== 109 - 110 -* Algorithm based scheduling engine ensures predictable operation year after year with no need to specifically specify each day 111 -* Area and/or Tag based schedules 112 -* Individual global events or grouped events 113 -* showrunner™ HUB UI Features 114 -** Day/Week/Month/Time Grid views display all events calculated by the scheduler engine 115 -** Tree based event/event groups 116 -** View Built-In Calendars and Groups 117 -** Create/Edit/Delete Custom Calendars and Groups 118 -* Execute last event on startup (configurable) to bring system in to correct state 119 -* Configurable Actions 120 -** Scene w/ option to override fade time 121 -** Change Keypad State (Enable/Disable/Disable Off) 122 -** Change Occupancy Mode (Occupancy/Vacancy/Disable/Last/Use Hardware) 123 -** Switch between Normal and After Hours (for Timeout) 124 -** Change CCT Mode (Auto/Manual) 125 -** Assign Manual CCT 126 -** Extend Occupancy Timeout setting 127 -** Change Scenes Recalled by Occupied/Vacant/On/Off 128 -** Shade Command (Open/Close) 129 -** Plug Load Mode (Off/On/Auto) 130 -* Copy Actions from Area to Area 131 -* AM, PM, and Relative to Astronomical (Sunrise/Sunset) Time References 132 -* Event Verification by Date in real-time with month calendar view and event description 133 -* Require a scene to be active before recalling the scheduled scene (optional) 134 -* Advanced Scheduling Feature (Licensed) 135 -** Event Include and/or Exclude by Calendar(s) and/or Calendar Group(s) 136 -** Calendar Groups consist of one or more Calendars 137 -** Calendars can be based on a Date Range or Date Pattern 138 -** Calendar Properties: 139 -*** Date Range: 140 -**** Start and End Dates 141 -**** Specific Dates selected using Date Picker 142 -**** Recur Annually Option 143 -*** Date Pattern: 144 -**** Year - Restrict to specific year or none 145 -**** Month - Restrict to specific Month(s) or none 146 -**** Week - Restrict to specific Week of the month or none 147 -**** Week Day - Restrict to specific day of the week or none 148 -**** Day - Restrict to a specific day of the month or none 149 -**** Optional: Offset - Offset date based on restrictions 150 -**** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter 151 -*** Enable/Disable 152 -** Pre-loaded with US Federal and common non-Federal US Holidays 153 -** Support for additional algorithms available upon request 154 - 155 -==== Circadian Rhythm/Dynamic White ==== 156 - 157 -* Global system CCT Level 158 -* Override CCT per area by scene or manually 159 -* Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 160 -* Time period based 161 -** Time References for start and end of period 162 -*** AM/PM 163 -*** Relative to 164 -**** Sunrise 165 -**** Sunset 166 -**** Solar Noon 167 -** Each time period can have the following setting for CCT 168 -*** Static 169 -*** Linear change over time 170 -*** Sensor with configured CCT when sensor is out of range 171 -* Supported with 0-10V, DMX, and DALI. Additional support via APIs 172 - 173 -==== Supported Hardware Features ==== 174 - 175 -Virtually the entire Crestron lighting product line is supported along with several 3rd party products 176 - 177 -* Common Settings to all devices 178 -** Contractor Label 179 -** Name 180 -** GlobalId 181 -** UniqueId (GUID) 182 -* HVAC 183 -** Temperature control by area 184 -** Support for some Crestron Thermostats, more can be added as needed 185 -** Support for some 3rd party systems, more can be added as needed 20 +** Crestron GLS-LCCT sensor integration for daylight tracking 21 +* Sophisticated Scheduling Engine 22 +** Configurable Actions by Area 23 +*** Scene 24 +**** Override Scene Fade Time 25 +*** Change Keypad State (Enable/Disable/Disable Off) 26 +*** Change Occupancy Mode (Occupancy/Vacancy/Disable/Last) 27 +*** Switch between Normal and After Hours (for Timeout) 28 +*** Change CCT Mode (Auto/Manual) 29 +*** Assign Manual CCT 30 +*** Extend Occupancy Timeout 31 +*** Change Scenes Recalled by Occupied/Vacant/On/Off 32 +*** Shade Command (Open/Close) 33 +*** Plug Load Mode (Off/On/Auto) 34 +** Copy Actions from Area to Area 35 +** AM, PM, and Astronomical (Sunrise/Sunset) Time References 36 +** Event Verification by Date in real-time with month calendar view and event description 37 +** Advanced Scheduling Feature (Licensed) 38 +*** Event Include and/or Exclude by Calendar(s) and/or Calendar Group(s) 39 +*** Calendar Groups consist of one or more Calendars 40 +*** Calendars can be based on a Date Range or Date Pattern 41 +*** Calendar Properties: 42 +**** Date Range: 43 +***** Start and End Dates or Specific Dates selected using Date Picker 44 +***** Does this Recur Annually 45 +**** Date Pattern: 46 +***** Year - Restrict to specific year or none 47 +***** Month - Restrict to specific Month(s) or none 48 +***** Week - Restrict to specific Week of the month or none 49 +***** Week Day - Restrict to specific day of the week or none 50 +***** Day - Restrict to a specific day of the month or none 51 +***** Optional: Offset - Offset date based on restrictions 52 +***** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter 53 +**** Enable/Disable 54 +*** Pre-loaded with US Federal and common non-Federal US Holidays 186 186 * Keypads 187 -** Support for common fixed configurations, user assignable at runtime. Includes all standard Crestron SpecsBuilder types. 188 -** Custom keypads with configurable actions per button at runtime 189 -*** Graphic based programming using showrunner™ HUB UI 190 -*** Master raise/lower button support allows assignment of currently selected load/shade/area/etc 191 -*** Custom button layouts w/ labels to assist with generating engravings 192 -** Flexible Templating Engine 193 -*** Create common keypad templates 194 -*** Apply keypad templates to individual keypads 195 -**** Remap hardware when template is applied 196 -**** Optionally exclude specific hardware and/or buttons 56 +** Support for common fixed configurations, user assignable 57 +** Custom keypads with configurable actions per button 197 197 ** User configurable area to control 198 -** Enable/Disable/Disable Off states 199 -** Prevent disable option 200 -** Flip raise/lower on common keypad types 201 -** Configurable hold time support, done in software if not supported by hardware 202 -** Configurable double tap time support if supported by hardware 203 -** Simulate keypads from showrunner™ HUB UI or console 204 -** Direct load mapping for some common keypads 205 -* Keyswitch/Contact Closure Inputs 206 -** Supports all versiport and digital inputs 207 -** Maintained and Momentary supported 208 -** Feedback output supported 209 -** Functions 210 -*** Override 211 -*** Scene Recall for Active and Inactive States 212 -*** Demand Response 213 -*** Actions for Active and Inactive States 214 -** Commonly used for FACP, override, demand response, and panic inputs 215 215 * Occupancy Sensors: 216 -** Occupancy configuration for CN andZUMLINKoccupancy sensors60 +** Occupancy configuration for CN type occupancy sensors 217 217 ** 3rd Party and Non-System occupancy sensor support 218 -** Occupancy/Vacancy/Disabled /UseHardware Logicmodes, user configurable62 +** Occupancy/Vacancy/Disabled modes, user configurable 219 219 ** Configure scenes recalled by area for occupancy and vacancy states 220 -** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance (open office 600sqft)64 +** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance 221 221 ** User configurable assignment of sensor to area(s) and load(s) 222 222 ** Occupancy sensors may feed data to multiple areas and loads 223 -** Last occupied and vacant times recorded 224 -* Output Signal 225 -** Logic object capable of triggering additional logic 226 -** Can trigger physical outputs via versiports/IOs 227 -** Supports conditional logic 228 -** Independent actions for active/inactive states 229 -** Configurable delays for active/inactive execution 230 230 * Partition sensors 231 231 ** Support for divisible areas 232 232 ** GLS-PART-CN with adjustable sensitivity 233 -** 3rd party sensor support via hardware inputs 234 -** User configurable Auto (use sensor) with manual override for Combined and Divided 235 -** Filtering to ignore noisy partition sensors 236 -** Change count and last change recorded help troubleshoot 237 -* Photocell 238 -** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior) 239 -** Configurable coefficient 240 -** Configurable thresholds 241 -** Assignable to individual loads for daylight harvesting 242 -* Serial Interface 243 -** RS-232/422/484 depending on hardware 244 -** Configurable Baud Rate and Com settings 245 -** Simple ASCII API for controlling/monitoring 246 -** Areas/Loads/Occupancy/Partition/Shades supported 247 -* Shades 248 -** Support for Crestron shades/drapes 249 -** Support for many 3rd party shade and drape systems 250 -* Zum Wired 251 -** Edge logic operation in Zum App mode 252 -*** Override occupancy logic and use showrunner™ logic 253 -** Central logic in CNET mode 254 -** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes 255 -* Zum Wireless 256 -** Override keypad buttons (except buttons 5-6) 257 -** Edge logic operation 258 -** Override occupancy behavior with showrunner™ logic 259 -** Direct load control 260 -** Scene save 261 -* Support for configuring hardware symbol properties on Crestron hardware 262 - 263 -==== Energy Efficiency ==== 264 - 70 +** 3rd party sensor support via versiport input 71 +** User configurable Auto, Combined, and Divided modes to override occ sensor, activated by UI or keypad 72 +* Maintained and Momentary Keyswitch/FACP/Override Input for scene recall or override activation 265 265 * Demand Response/Load Shedding 266 266 ** Automatic via sensor input 267 -** Manually via user input 268 -* Calculated or Measured Power (Watts) 269 -* Energy Efficiency visualization on floorplan 270 - 271 -==== Security ==== 272 - 273 -* Touchscreens: Global User and Technician Passcodes, user configurable. 274 -* showrunner™ HUB 275 -** Role Based permissions by Group 276 -** Granular Create, Edit, View, Delete, and Execute permissions by Role 277 -** Users and API Users assignable to groups 278 -** Restrict Group by area and tag 279 -** HTTPS enforced 280 -** Auto session timeout 281 -** Login via username/password or PIN code 282 -** Support for Processor and internal user database with configurable priority or specify one exclusively 283 -** Best practices for password handling 284 -* API using AWSv4 scheme for authentication per request for maximum security 285 -* Encrypted storage of all credentials and keys 286 - 287 -==== General Features ==== 288 - 75 +** Manually via keypad 76 +* Configurable maximum demand response level by load 77 +* Dynamic addition/deletion/assignment/configuration of loads 78 +* Dynamic addition/deletion of areas 79 +* User editable labeling of areas, loads, keypads, occupancy sensors, and schedules 80 +* Daylight Harvesting sensor to load assignment and settings adjustment 81 +* Global User and Technician Passcodes, user configurable. 289 289 * User configurable time zone, location, and current time 83 +* Addressing/Grouping/Driver Replacement for DALI. DALI groups are referenced by their controlled load simplifying addressing and replacement procedures. 290 290 * Addressing and Verification of Cresnet devices by serial number 291 291 * Cresnet Device Serial Number capture 292 -* Extensive console command interface (CLI) 293 -* Simulate sensor and keypad inputs to test without hardware 294 -* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 295 -Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only. 296 - 297 -==== Diagnostics ==== 298 - 299 -* Provides diagnostic data when supported by hardware 300 -* Diagnostics available from load controllers all the way up to Cresnet bridges 301 -* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only 302 - 303 -==== Discovery ==== 304 - 305 -* Discover and automatically define Zum Wired hardware 306 -* Discover and automatically define Zum Wireless hardware 307 -* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number 308 -* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming 309 - 310 -==== Event Log ==== 311 - 312 -* Central logging mechanism 313 -* Messages time stamped 314 -* CSV format 315 -* Multiple logging levels: Critical, Error, Warning, Information, Debug, Trace 316 -* Filter by logging level 317 -* Filter by source object 318 -* Filter by GlobalId 319 -* Trace option allows tracking the triggering event through execution 320 -* Thread option allows tracking of the thread executing 321 -* Logging to console 322 -* Logging to file 323 -* Logging to remote syslog (via processor) 324 -* Heartbeat option with configurable interval 325 -* Debugging writes to the event log 326 -* Global Enable flag 327 - 328 -==== Extensibility ==== 329 - 330 -* Actions 331 -** Logic objects exist on showrunner™ objects 332 -** Functionality can be triggered via APIs 333 -** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within showrunner™ 334 -* Extensions 335 -** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem 336 -** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]] 337 -* Global Actions 338 -** Allow manual or input triggered operations against the system 339 -** Can be custom programmed at runtime 340 - 341 -==== User Interfaces ==== 342 - 343 -* showrunner™ HUB 344 -** Web based, touch and mouse friendly design 345 -** Runs directly on the processor or VC-4 instance 346 -** HTTPS required 347 -** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience 348 -** Node Tree 349 -*** Organize areas in logical locations based on physical topology 350 -*** Searchable, only shows matching areas 351 -** Floorplans 352 -*** Assigned to a node, multiple floor plans are supported 353 -*** Pinch zoom/touch pan 354 -*** User provided floorplan 355 -*** Draw directly on floorplan for areas and objects 356 -**** Areas 357 -**** Loads 358 -**** Partitions 359 -**** Occupancy Sensors 360 -**** Keypads 361 -**** Photocells 362 -*** Crestron product line icons area available to match the installed sensor 363 -*** Interactive control screens depending on clicked object 364 -*** Multiple different views help visualize data 365 -**** Area View - Shows areas with user selected colors 366 -**** Tags View - Shows areas based on their assigned tag 367 -**** Occupancy View - Shows areas based on their current occupancy status and how recently that status changed 368 -**** Intensity View - Shows areas shaded based on the current overall light intensity 369 -**** Energy View - Shows areas shaded based on the areas current energy efficiency from efficient to inefficient 370 -*** Automatic navigation to area when selected from the node tree 371 -*** Fullscreen view 372 -** Schedule 373 -*** See [[Scheduling Features>>doc:||anchor="Scheduling Features"]] for more info 374 -** Reports 375 -*** Interactive data 376 -**** Area Loads 377 -**** Area Scenes 378 -**** Areas 379 -**** Cresnet (Query) 380 -**** Device Status 381 -**** Events 382 -**** Keypads 383 -** Setup 384 -*** Device Diagnostic - Show Diagnostic data from supported devices 385 -*** Hardware Management - Tree view of Ethernet, Cresnet, and RF topologies 386 -*** File Management - Manage config, license, currently active config, and backup/restore operations 387 -*** Global Actions - Add/Delete/Configure 388 -*** Integrations - Manage integrations with other showrunner™ systems 389 -*** Keypad Configuration - Configure keypads 390 -*** Maps - Add floorplan images 391 -*** Network - DHCP Server (for processors without routers only) 392 -*** System Settings - Manage various system settings 393 -*** Tags - Manage tags and association of tags with areas 394 -*** User Management - Manage users/groups/API users 395 -* Crestron TS/TSWs and Crestron App (iPad/iPhone/Android) 396 -** Area Control Screen 397 -*** Select Area (Can be disabled or restricted) 398 -*** Divide/Combine status, if divisible 399 -*** Occupancy/vacancy status, if has an occupancy sensor 400 -*** Individual load controls 401 -*** Dynamic white color temperature control, if supported 402 -*** RGB color picker, if load supported 403 -*** Scenes, up to 20, save with press and hold 404 -*** Master Raise/Lower 405 -*** Global Actions, if defined, can be hidden 406 -*** HVAC controls, if supported 407 -*** Shade controls, if supported 408 -*** Passcode protected, if enabled 409 -** Setup Screen 410 -*** Passcode protected, if enabled 411 -*** Area Configuration 412 -**** Area List 413 -**** Area Name, editable 414 -**** Load Configuration - Configure load control type and labeling, test fixture operation 415 -**** Occupancy Setup - Configure area occupancy behavior and occupancy settings 416 -**** Daylight Harvesting - Configure daylight harvesting settings per load/scene 417 -**** Scene Setup - Configure and add/delete scenes 418 -**** Properties - Configure area behavior settings 419 -**** Add/Delete areas 420 -*** Area Layout - Configure partition sensors and area assignments to partition sensors 421 -*** Crestron Integration - Configure EISCs 422 -*** Device Addressing - Address and verify Cresnet devices 423 -*** Keypad Configuration - Configure keypad type, area assignment, and enable status 424 -*** Load Hardware - Configure loads and load controllers 425 -*** Location and System Clock - View/Set system clock, site lat/lon, and timezone 426 -*** Occupancy Assignment - Assign occupancy sensors to loads/areas 427 -*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events) 428 -*** Security Settings - Enable/Disable/Change PIN codes 429 -*** Zum Integration - Configure export to Zum Floor Hub 430 -*** Help Screen - Support contact information, showrunner version list, and license status 431 -** Custom Logo option for splash screen 432 -** Optional floor plan area selection, zoom/pan are NOT supported, static image only 433 -** Optional partition control on floor plan screen 434 - 435 -=== Integrations === 436 - 437 -* AV Integration protocol via serial port, simple ASCII protocol with feedback 438 -* BACnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron) 439 -** Global 440 -*** Override 441 -*** Demand Response 442 -*** Device Offline Count 443 -*** Alarm 444 -*** System Normal/After Hours 445 -** Area Specific 446 -*** showrunner™ Mode 447 -**** Occupancy Status 448 -**** Occupancy Enable 449 -**** Scenes 450 -**** Loads 451 -**** Photocell Level 452 -**** Overall Intensity 453 -**** Power (watts) 454 -*** Zum Hub Emulation Mode 455 -**** Online 456 -**** On 457 -**** Scenes 458 -**** Occupied 459 -**** Occupancy Sensor Enable 460 -* Crestron Fusion EM (Licensed Feature) 461 -** Scenes, Recall and Save 462 -** Load Control 463 -** Occupancy Status 464 -** Photocell 465 -* e-DMX Receiver 466 -** SACN and/or Art-Net 467 -** Enable/Disable control for loads using e-DMX channel value 468 -** Map DMX to showrunner loads 469 -* EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client) 470 -** Configurable IP address and IP-ID, change at runtime 471 -** Configurable rooms to export, change at runtime 472 -** Changes generate new RSD file at runtime that may be provided to the AV programmer 473 -* HTTP REST API w/ Authorization 474 -* Lightweight API provides real-time control/feedback using CoAP 475 -* TCP Interface using simple ASCII commands, subscriptions supported 476 -* UDP Receiver using simple ASCII commands 477 -* Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature) 86 +* Configurable Global Actions with touchpanel trigger 87 +* User configurable Crestron EISC Integration with ability to change IP Address and IP-ID of remote Crestron system as well as Areas shared on the fly. RSD file is automatically generated and link is provided for downloading of RSD file. 478 478 * Remote hardware support from neighbor ShowRunner System: 479 -** Allows a centralShowRunner system to integrate edgeprocessors89 +** Allows a master ShowRunner system to integrate slave processors 480 480 ** AV Serial Interface 481 481 ** Loads 482 482 ** Controllers ... ... @@ -485,9 +485,19 @@ 485 485 ** Occupancy Sensor (including setup for Cresnet sensors) 486 486 ** Partition Sensors (including setup for Cresnet sensors) 487 487 ** Photocells 98 +* Web based reporting directly from the processor allows generation of as built documentation: Cresnet Discovery, Device Status, Event Schedule, Keypad Schedule, Load Schedule, and Panel Schedule 488 488 489 -=== =Reporting====100 +=== Integrations === 490 490 102 +* AV Integration protocol via serial port 103 +* BACNET Support for integration of Areas, Loads (Licensed Feature) 104 +* Crestron Fusion (Licensed Feature) 105 +* E-DMX Receive - Receive DMX (SACN or Art-Net) and translate to ShowRunner Loads 106 +* EISC Export for AV Integration, dynamic creation from the UI (3-series or classic) 107 +* Zum Floor Hub Support for integration, Export SHOWRUNNER™ areas to the Floor Hub (Licensed Feature) 108 + 109 +=== Reporting === 110 + 491 491 ShowRunner provides a website via the processor's internal webserver with the following reports. All data is live at the time of the generation of the report. 492 492 493 493 * Area Load Schedule - Load schedule by Area