Changes for page Features

Last modified by Scott Kohlmann on 2023/04/21 15:15

From version 6.1
edited by Mark Kohlmann
on 2022/10/17 17:48
Change comment: There is no comment for this version
To version 5.1
edited by Mark Kohlmann
on 2022/10/14 23:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,22 +1,5 @@
1 -showrunner™ is a commercial lighting control and lighting management system.  showrunner™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.  Hardware support is extensive and growing all the time.  This documents is not a complete feature list and Chief Integrations reserves the right to make modifications at any time.
1 +showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.  Hardware support is extensive and growing all the time.
2 2  
3 -{{box cssClass="floatinginfobox"}}
4 -(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %)
5 -**CONTENTS**
6 -
7 -{{toc start="4"/}}
8 -{{/box}}
9 -
10 -==== Key Capabilities ====
11 -
12 -* Configuration driven with runtime configuration support enables rapid commissioning of commercial lighting systems
13 -* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements
14 -* Large native hardware support with the option to extend support to new hardware quickly and easily
15 -* Touchpanel and web based UIs cover users needs
16 -* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers
17 -* Floorplans with pinch, zoom, and insight!
18 -* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes
19 -
20 20  ==== Area Features ====
21 21  
22 22  * Lighting Loads
... ... @@ -85,7 +85,7 @@
85 85  * Demand Response Level
86 86  * Enable/Disable/Override states
87 87  * Option to ignore long fade times if the loads is off
88 -* Option recall last on level
71 +* Option recall last level
89 89  * Individual daylight harvesting settings, enabled/disabled by scene
90 90  ** Open/closed loop
91 91  ** Min/Max levels
... ... @@ -105,6 +105,7 @@
105 105  * DALI (DIN-DALI-2/ZUMNET-JBOX-DALI Legacy mode)
106 106  ** Addressing/Grouping/Driver Replacement for DALI.  DALI groups are referenced by their controlled load simplifying addressing and replacement procedures.
107 107  
91 +(% class="wikigeneratedid" %)
108 108  ==== Scheduling Features ====
109 109  
110 110  * Algorithm based scheduling engine ensures predictable operation year after year with no need to specifically specify each day
... ... @@ -150,7 +150,6 @@
150 150  **** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter
151 151  *** Enable/Disable
152 152  ** Pre-loaded with US Federal and common non-Federal US Holidays
153 -** Support for additional algorithms available upon request
154 154  
155 155  ==== Circadian Rhythm/Dynamic White ====
156 156  
... ... @@ -168,7 +168,7 @@
168 168  *** Static
169 169  *** Linear change over time
170 170  *** Sensor with configured CCT when sensor is out of range
171 -* Supported with 0-10V, DMX, and DALI. Additional support via APIs
154 +* Supported with 0-10V, DMX, and DALI
172 172  
173 173  ==== Supported Hardware Features ====
174 174  
... ... @@ -184,7 +184,7 @@
184 184  ** Support for some Crestron Thermostats, more can be added as needed
185 185  ** Support for some 3rd party systems, more can be added as needed
186 186  * Keypads
187 -** Support for common fixed configurations, user assignable at runtime. Includes all standard Crestron SpecsBuilder types.
170 +** Support for common fixed configurations, user assignable at runtime
188 188  ** Custom keypads with configurable actions per button at runtime
189 189  *** Graphic based programming using showrunner™ HUB UI
190 190  *** Master raise/lower button support allows assignment of currently selected load/shade/area/etc
... ... @@ -211,13 +211,12 @@
211 211  *** Scene Recall for Active and Inactive States
212 212  *** Demand Response
213 213  *** Actions for Active and Inactive States
214 -** Commonly used for FACP, override, demand response, and panic inputs
215 215  * Occupancy Sensors:
216 216  ** Occupancy configuration for CN and ZUMLINK occupancy sensors
217 217  ** ​3rd Party and Non-System occupancy sensor support
218 218  ** Occupancy/Vacancy/Disabled/Use Hardware Logic modes, user configurable
219 219  ** Configure scenes recalled by area for occupancy and vacancy states
220 -** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance (open office 600sqft)
202 +** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance
221 221  ** User configurable assignment of sensor to area(s) and load(s)
222 222  ** Occupancy sensors may feed data to multiple areas and loads
223 223  ** Last occupied and vacant times recorded
... ... @@ -231,9 +231,9 @@
231 231  ** Support for divisible areas
232 232  ** GLS-PART-CN with adjustable sensitivity
233 233  ** 3rd party sensor support via hardware inputs
234 -** User configurable Auto (use sensor) with manual override for Combined and Divided
216 +** User configurable Auto, Combined, and Divided
235 235  ** Filtering to ignore noisy partition sensors
236 -** Change count and last change recorded help troubleshoot
218 +** Change count and last change recorded
237 237  * Photocell
238 238  ** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior)
239 239  ** Configurable coefficient
... ... @@ -240,25 +240,13 @@
240 240  ** Configurable thresholds
241 241  ** Assignable to individual loads for daylight harvesting
242 242  * Serial Interface
243 -** RS-232/422/484 depending on hardware
225 +** RS-232/422/484
244 244  ** Configurable Baud Rate and Com settings
245 -** Simple ASCII API for controlling/monitoring
227 +** Simple ASCII API for controlling/montioring
246 246  ** Areas/Loads/Occupancy/Partition/Shades supported
247 247  * Shades
248 248  ** Support for Crestron shades/drapes
249 249  ** Support for many 3rd party shade and drape systems
250 -* Zum Wired
251 -** Edge logic operation in Zum App mode
252 -*** Override occupancy logic and use showrunner™ logic
253 -** Central logic in CNET mode
254 -** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes
255 -* Zum Wireless
256 -** Override keypad buttons (except buttons 5-6)
257 -** Edge logic operation
258 -** Override occupancy behavior with showrunner™ logic
259 -** Direct load control
260 -** Scene save
261 -* Support for configuring hardware symbol properties on Crestron hardware
262 262  
263 263  ==== Energy Efficiency ====
264 264  
... ... @@ -279,52 +279,19 @@
279 279  ** HTTPS enforced
280 280  ** Auto session timeout
281 281  ** Login via username/password or PIN code
282 -** Support for Processor and internal user database with configurable priority or specify one exclusively
252 +** Support for Processor or internal user database
283 283  ** Best practices for password handling
284 284  * API using AWSv4 scheme for authentication per request for maximum security
285 -* Encrypted storage of all credentials and keys
286 286  
287 -==== General Features ====
256 +==== System Features ====
288 288  
289 289  * User configurable time zone, location, and current time
290 290  * Addressing and Verification of Cresnet devices by serial number
291 291  * Cresnet Device Serial Number capture
261 +* Configurable Global Actions with touchpanel trigger
292 292  * Extensive console command interface (CLI)
293 -* Simulate sensor and keypad inputs to test without hardware
294 -* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 
295 -Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only.
296 296  
297 -==== Diagnostics ====
298 -
299 -* Provides diagnostic data when supported by hardware
300 -* Diagnostics available from load controllers all the way up to Cresnet bridges
301 -* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only
302 -
303 -==== Discovery ====
304 -
305 -* Discover and automatically define Zum Wired hardware
306 -* Discover and automatically define Zum Wireless hardware
307 -* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number
308 -* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming
309 -
310 -==== Event Log ====
311 -
312 -* Central logging mechanism
313 -* Messages time stamped
314 -* CSV format
315 -* Multiple logging levels: Critical, Error, Warning, Information, Debug, Trace
316 -* Filter by logging level
317 -* Filter by source object
318 -* Filter by GlobalId
319 -* Trace option allows tracking the triggering event through execution
320 -* Thread option allows tracking of the thread executing
321 -* Logging to console
322 -* Logging to file
323 -* Logging to remote syslog (via processor)
324 -* Heartbeat option with configurable interval
325 -* Debugging writes to the event log
326 -* Global Enable flag
327 -
264 +(% class="wikigeneratedid" %)
328 328  ==== Extensibility ====
329 329  
330 330  * Actions
... ... @@ -335,13 +335,13 @@
335 335  ** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem
336 336  ** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]]
337 337  * Global Actions
338 -** Allow manual or input triggered operations against the system
275 +** Allow minimal or input triggered operations against the system
339 339  ** Can be custom programmed at runtime
340 340  
341 341  ==== User Interfaces ====
342 342  
343 343  * showrunner™ HUB
344 -** Web based, touch and mouse friendly design
281 +** Web based
345 345  ** Runs directly on the processor or VC-4 instance
346 346  ** HTTPS required
347 347  ** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience
... ... @@ -393,49 +393,11 @@
393 393  *** Tags - Manage tags and association of tags with areas
394 394  *** User Management - Manage users/groups/API users
395 395  * Crestron TS/TSWs and Crestron App (iPad/iPhone/Android)
396 -** Area Control Screen
397 -*** Select Area (Can be disabled or restricted)
398 -*** Divide/Combine status, if divisible
399 -*** Occupancy/vacancy status, if has an occupancy sensor
400 -*** Individual load controls
401 -*** Dynamic white color temperature control, if supported
402 -*** RGB color picker, if load supported
403 -*** Scenes, up to 20, save with press and hold
404 -*** Master Raise/Lower
405 -*** Global Actions, if defined, can be hidden
406 -*** HVAC controls, if supported
407 -*** Shade controls, if supported
408 -*** Passcode protected, if enabled
409 -** Setup Screen
410 -*** Passcode protected, if enabled
411 -*** Area Configuration
412 -**** Area List
413 -**** Area Name, editable
414 -**** Load Configuration - Configure load control type and labeling, test fixture operation
415 -**** Occupancy Setup - Configure area occupancy behavior and occupancy settings
416 -**** Daylight Harvesting - Configure daylight harvesting settings per load/scene
417 -**** Scene Setup - Configure and add/delete scenes
418 -**** Properties - Configure area behavior settings
419 -**** Add/Delete areas
420 -*** Area Layout - Configure partition sensors and area assignments to partition sensors
421 -*** Crestron Integration - Configure EISCs
422 -*** Device Addressing - Address and verify Cresnet devices
423 -*** Keypad Configuration - Configure keypad type, area assignment, and enable status
424 -*** Load Hardware - Configure loads and load controllers
425 -*** Location and System Clock - View/Set system clock, site lat/lon, and timezone
426 -*** Occupancy Assignment - Assign occupancy sensors to loads/areas
427 -*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events)
428 -*** Security Settings - Enable/Disable/Change PIN codes
429 -*** Zum Integration - Configure export to Zum Floor Hub
430 -*** Help Screen - Support contact information, showrunner version list, and license status
431 -** Custom Logo option for splash screen
432 -** Optional floor plan area selection, zoom/pan are NOT supported, static image only
433 -** Optional partition control on floor plan screen
434 434  
435 435  === Integrations ===
436 436  
437 -* AV Integration protocol via serial port, simple ASCII protocol with feedback
438 -* BACnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron)
336 +* AV Integration protocol via serial port
337 +* BACNnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron)
439 439  ** Global
440 440  *** Override
441 441  *** Demand Response
... ... @@ -457,12 +457,12 @@
457 457  **** Scenes
458 458  **** Occupied
459 459  **** Occupancy Sensor Enable
460 -* Crestron Fusion EM (Licensed Feature)
359 +* Crestron Fusion (Licensed Feature)
461 461  ** Scenes, Recall and Save
462 462  ** Load Control
463 463  ** Occupancy Status
464 464  ** Photocell
465 -* e-DMX Receiver
364 +* E-DMX Receiver
466 466  ** SACN and/or Art-Net
467 467  ** Enable/Disable control for loads using e-DMX channel value
468 468  ** Map DMX to showrunner loads
... ... @@ -471,7 +471,7 @@
471 471  ** Configurable rooms to export, change at runtime
472 472  ** Changes generate new RSD file at runtime that may be provided to the AV programmer
473 473  * HTTP REST API w/ Authorization
474 -* Lightweight API provides real-time control/feedback using CoAP
373 +* Lightweight API provides real-time control/feedback of hardware using CoAP
475 475  * TCP Interface using simple ASCII commands, subscriptions supported
476 476  * UDP Receiver using simple ASCII commands
477 477  * Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature)
... ... @@ -486,7 +486,7 @@
486 486  ** Partition Sensors (including setup for Cresnet sensors)
487 487  ** Photocells
488 488  
489 -==== Reporting ====
388 +=== Reporting ===
490 490  
491 491  ShowRunner provides a website via the processor's internal webserver with the following reports.  All data is live at the time of the generation of the report.
492 492