Changes for page Features
Last modified by Scott Kohlmann on 2023/04/21 15:15
From version 5.2
edited by Mark Kohlmann
on 2022/10/16 17:23
on 2022/10/16 17:23
Change comment:
There is no comment for this version
To version 9.1
edited by Scott Kohlmann
on 2023/04/21 15:15
on 2023/04/21 15:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,5 +1,22 @@ 1 - showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time.1 +ShowRunnerCLC™ is a commercial lighting control and lighting management system. ShowRunnerCLC™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time. This document is not a complete feature list and Chief Integrations reserves the right to make modifications at any time. 2 2 3 +{{box cssClass="floatinginfobox"}} 4 +(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %) 5 +**CONTENTS** 6 + 7 +{{toc start="4"/}} 8 +{{/box}} 9 + 10 +==== Key Capabilities ==== 11 + 12 +* Configuration driven with runtime adaptability enables rapid commissioning of commercial lighting systems 13 +* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements 14 +* Large native hardware support with the ability to extend support to new hardware quickly and easily 15 +* Touchpanel and web based UIs cover users' needs 16 +* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers 17 +* Floorplans with pinch, zoom, and insight! 18 +* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes 19 + 3 3 ==== Area Features ==== 4 4 5 5 * Lighting Loads ... ... @@ -8,7 +8,7 @@ 8 8 * User configurable scene name, fade time, and load include by scene 9 9 * Individual scenes may be locked to prevent changing their settings 10 10 * Individual load control within an area 11 -* Selectareafrom touchpanel, areas can be restricted by panel28 +* Area selection from touchpanel, areas can be restricted by panel 12 12 * RGB controls for applicable fixtures, saved per scene 13 13 * Configurable Load Grouping for load consolidation including linked/group area loads 14 14 * Dynamic White/Circadian Rhythm CCT Control ... ... @@ -68,7 +68,7 @@ 68 68 * Demand Response Level 69 69 * Enable/Disable/Override states 70 70 * Option to ignore long fade times if the loads is off 71 -* Option recall last on level 88 +* Option to recall last on level 72 72 * Individual daylight harvesting settings, enabled/disabled by scene 73 73 ** Open/closed loop 74 74 ** Min/Max levels ... ... @@ -90,10 +90,10 @@ 90 90 91 91 ==== Scheduling Features ==== 92 92 93 -* Algorithm based scheduling engine ensures predictable operation year after year with no need to specificallyspecify each day110 +* Algorithm based scheduling engine ensures predictable operation year after year with no need to define a system wide schedule per-day 94 94 * Area and/or Tag based schedules 95 95 * Individual global events or grouped events 96 -* showrunner™ HUB UI Features113 +* ShowRunnerCLC™ HUB UI Features 97 97 ** Day/Week/Month/Time Grid views display all events calculated by the scheduler engine 98 98 ** Tree based event/event groups 99 99 ** View Built-In Calendars and Groups ... ... @@ -169,7 +169,7 @@ 169 169 * Keypads 170 170 ** Support for common fixed configurations, user assignable at runtime. Includes all standard Crestron SpecsBuilder types. 171 171 ** Custom keypads with configurable actions per button at runtime 172 -*** Graphic based programming using showrunner™HUB189 +*** Graphic based programming using ShowRunnerHUB™ UI 173 173 *** Master raise/lower button support allows assignment of currently selected load/shade/area/etc 174 174 *** Custom button layouts w/ labels to assist with generating engravings 175 175 ** Flexible Templating Engine ... ... @@ -183,7 +183,7 @@ 183 183 ** Flip raise/lower on common keypad types 184 184 ** Configurable hold time support, done in software if not supported by hardware 185 185 ** Configurable double tap time support if supported by hardware 186 -** Simulate keypads from showrunner™ HUB UI or console203 +** Simulate keypads from ShowRunnerCLC™ HUB UI or console 187 187 ** Direct load mapping for some common keypads 188 188 * Keyswitch/Contact Closure Inputs 189 189 ** Supports all versiport and digital inputs ... ... @@ -194,6 +194,7 @@ 194 194 *** Scene Recall for Active and Inactive States 195 195 *** Demand Response 196 196 *** Actions for Active and Inactive States 214 +** Commonly used for FACP, override, demand response, and panic inputs 197 197 * Occupancy Sensors: 198 198 ** Occupancy configuration for CN and ZUMLINK occupancy sensors 199 199 ** 3rd Party and Non-System occupancy sensor support ... ... @@ -216,6 +216,7 @@ 216 216 ** User configurable Auto (use sensor) with manual override for Combined and Divided 217 217 ** Filtering to ignore noisy partition sensors 218 218 ** Change count and last change recorded help troubleshoot 237 +** Hardware not required, may be setup as a virtual sensor 219 219 * Photocell 220 220 ** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior) 221 221 ** Configurable coefficient ... ... @@ -222,13 +222,25 @@ 222 222 ** Configurable thresholds 223 223 ** Assignable to individual loads for daylight harvesting 224 224 * Serial Interface 225 -** RS-232/422/484 244 +** RS-232/422/484 depending on hardware 226 226 ** Configurable Baud Rate and Com settings 227 -** Simple ASCII API for controlling/mon tioring246 +** Simple ASCII API for controlling/monitoring 228 228 ** Areas/Loads/Occupancy/Partition/Shades supported 229 229 * Shades 230 230 ** Support for Crestron shades/drapes 231 231 ** Support for many 3rd party shade and drape systems 251 +* Zum Wired 252 +** Edge logic operation in Zum App mode 253 +*** Override occupancy logic and use ShowRunnerCLC™ logic 254 +** Central logic in CNET mode 255 +** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes 256 +* Zum Wireless 257 +** Override keypad buttons (except buttons 5-6) 258 +** Edge logic operation 259 +** Override occupancy behavior with ShowRunnerCLC™ logic 260 +** Direct load control 261 +** Scene save 262 +* Support for configuring hardware symbol properties on Crestron hardware 232 232 233 233 ==== Energy Efficiency ==== 234 234 ... ... @@ -241,7 +241,7 @@ 241 241 ==== Security ==== 242 242 243 243 * Touchscreens: Global User and Technician Passcodes, user configurable. 244 -* showrunner™ HUB275 +* ShowRunnerCLC™ HUB 245 245 ** Role Based permissions by Group 246 246 ** Granular Create, Edit, View, Delete, and Execute permissions by Role 247 247 ** Users and API Users assignable to groups ... ... @@ -249,20 +249,36 @@ 249 249 ** HTTPS enforced 250 250 ** Auto session timeout 251 251 ** Login via username/password or PIN code 252 -** Support for Processor orinternal user database283 +** Support for Processor and internal user database with configurable priority or specify one exclusively 253 253 ** Best practices for password handling 254 254 * API using AWSv4 scheme for authentication per request for maximum security 286 +* Encrypted storage of all credentials and keys 255 255 256 -==== SystemFeatures ====288 +==== General Features ==== 257 257 258 258 * User configurable time zone, location, and current time 259 259 * Addressing and Verification of Cresnet devices by serial number 260 260 * Cresnet Device Serial Number capture 261 -* Configurable Global Actions with touchpanel trigger 262 262 * Extensive console command interface (CLI) 294 +* Simulate sensor and keypad inputs to test without hardware 295 +* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 296 +Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only. 263 263 264 - EventLog / Auditing298 +==== Diagnostics ==== 265 265 300 +* Provides diagnostic data when supported by hardware 301 +* Diagnostics available from load controllers all the way up to Cresnet bridges 302 +* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only 303 + 304 +==== Discovery ==== 305 + 306 +* Discover and automatically define Zum Wired hardware 307 +* Discover and automatically define Zum Wireless hardware 308 +* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number 309 +* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming 310 + 311 +==== Event Log ==== 312 + 266 266 * Central logging mechanism 267 267 * Messages time stamped 268 268 * CSV format ... ... @@ -282,20 +282,20 @@ 282 282 ==== Extensibility ==== 283 283 284 284 * Actions 285 -** Logic objects exist on showrunner™ objects332 +** Logic objects exist on ShowRunnerCLC™ objects 286 286 ** Functionality can be triggered via APIs 287 -** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within showrunner™334 +** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within ShowRunnerCLC™ 288 288 * Extensions 289 -** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem336 +** Extension model allows customization and additional functionality to be added to the ShowRunnerCLC™ ecosystem 290 290 ** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]] 291 291 * Global Actions 292 -** Allow m inimal or input triggered operations against the system339 +** Allow manual or input triggered operations against the system 293 293 ** Can be custom programmed at runtime 294 294 295 295 ==== User Interfaces ==== 296 296 297 -* showrunner™HUB298 -** Web based 344 +* ShowRunnerHUB™ 345 +** Web based, touch and mouse friendly design 299 299 ** Runs directly on the processor or VC-4 instance 300 300 ** HTTPS required 301 301 ** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience ... ... @@ -339,19 +339,57 @@ 339 339 *** Hardware Management - Tree view of Ethernet, Cresnet, and RF topologies 340 340 *** File Management - Manage config, license, currently active config, and backup/restore operations 341 341 *** Global Actions - Add/Delete/Configure 342 -*** Integrations - Manage integrations with other showrunner™ systems389 +*** Integrations - Manage integrations with other ShowRunnerCLC™ systems 343 343 *** Keypad Configuration - Configure keypads 344 -*** Maps - Add floorplan images 391 +*** Maps - Add/Manage floorplan images 345 345 *** Network - DHCP Server (for processors without routers only) 346 346 *** System Settings - Manage various system settings 347 347 *** Tags - Manage tags and association of tags with areas 348 348 *** User Management - Manage users/groups/API users 349 349 * Crestron TS/TSWs and Crestron App (iPad/iPhone/Android) 397 +** Area Control Screen 398 +*** Select Area (Can be disabled or restricted) 399 +*** Divide/Combine status, if divisible 400 +*** Occupancy/vacancy status, if has an occupancy sensor 401 +*** Individual load controls 402 +*** Dynamic white color temperature control, if supported 403 +*** RGB color picker, if load supported 404 +*** Scenes, up to 20, save with press and hold 405 +*** Master Raise/Lower 406 +*** Global Actions, if defined, can be hidden 407 +*** HVAC controls, if supported 408 +*** Shade controls, if supported 409 +*** Passcode protected, if enabled 410 +** Setup Screen 411 +*** Passcode protected, if enabled 412 +*** Area Configuration 413 +**** Area List 414 +**** Area Name, editable 415 +**** Load Configuration - Configure load control type and labeling, test fixture operation 416 +**** Occupancy Setup - Configure area occupancy behavior and occupancy settings 417 +**** Daylight Harvesting - Configure daylight harvesting settings per load/scene 418 +**** Scene Setup - Configure and add/delete scenes 419 +**** Properties - Configure area behavior settings 420 +**** Add/Delete areas 421 +*** Area Layout - Configure partition sensors and area assignments to partition sensors 422 +*** Crestron Integration - Configure EISCs 423 +*** Device Addressing - Address and verify Cresnet devices 424 +*** Keypad Configuration - Configure keypad type, area assignment, and enable status 425 +*** Load Hardware - Configure loads and load controllers 426 +*** Location and System Clock - View/Set system clock, site lat/lon, and timezone 427 +*** Occupancy Assignment - Assign occupancy sensors to loads/areas 428 +*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events) 429 +*** Security Settings - Enable/Disable/Change PIN codes 430 +*** Zum Integration - Configure export to Zum Floor Hub 431 +*** Help Screen - Support contact information, ShowRunnerCLC™ version list, and license status 432 +** Custom Logo option for splash screen 433 +** Optional floor plan area selection, zoom/pan are NOT supported, static image only 434 +** Optional partition control on floor plan screen 350 350 351 351 === Integrations === 352 352 353 -* AV Integration protocol via serial port 354 -* BAC Nnet Support for integration of Areas, Loads (Licensed Feature, bothshowrunner and Crestron)438 +* AV Integration protocol via serial port, simple ASCII protocol with feedback 439 +* BACnet Support for integration of Areas, Loads (Licensed Feature, both ShowRunnerCLC™ and Crestron) 355 355 ** Global 356 356 *** Override 357 357 *** Demand Response ... ... @@ -359,7 +359,7 @@ 359 359 *** Alarm 360 360 *** System Normal/After Hours 361 361 ** Area Specific 362 -*** showrunner™ Mode447 +*** ShowRunnerCLC™ Mode 363 363 **** Occupancy Status 364 364 **** Occupancy Enable 365 365 **** Scenes ... ... @@ -373,25 +373,25 @@ 373 373 **** Scenes 374 374 **** Occupied 375 375 **** Occupancy Sensor Enable 376 -* Crestron Fusion (Licensed Feature) 461 +* Crestron Fusion EM (Licensed Feature) 377 377 ** Scenes, Recall and Save 378 378 ** Load Control 379 379 ** Occupancy Status 380 380 ** Photocell 381 -* E-DMX Receiver466 +* e-DMX Receiver 382 382 ** SACN and/or Art-Net 383 383 ** Enable/Disable control for loads using e-DMX channel value 384 -** Map DMX to showrunner loads469 +** Map DMX to ShowRunnerCLC™ loads 385 385 * EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client) 386 386 ** Configurable IP address and IP-ID, change at runtime 387 387 ** Configurable rooms to export, change at runtime 388 388 ** Changes generate new RSD file at runtime that may be provided to the AV programmer 389 389 * HTTP REST API w/ Authorization 390 -* Lightweight API provides real-time control/feedback of hardwareusing CoAP475 +* Lightweight API provides real-time control/feedback using CoAP 391 391 * TCP Interface using simple ASCII commands, subscriptions supported 392 392 * UDP Receiver using simple ASCII commands 393 -* Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature)394 -* Remote hardware support from neighbor ShowRunner System: 478 +* Zum Floor Hub Support for integration, Export ShowRunnerCLC™ areas to the Floor Hub (Licensed Feature) 479 +* Remote hardware support from neighbor ShowRunnerCLC™ System: 395 395 ** Allows a central ShowRunner system to integrate edge processors 396 396 ** AV Serial Interface 397 397 ** Loads ... ... @@ -402,7 +402,7 @@ 402 402 ** Partition Sensors (including setup for Cresnet sensors) 403 403 ** Photocells 404 404 405 -=== Reporting === 490 +==== Reporting ==== 406 406 407 407 ShowRunner provides a website via the processor's internal webserver with the following reports. All data is live at the time of the generation of the report. 408 408