Changes for page Features
Last modified by Scott Kohlmann on 2023/04/21 15:15
From version 5.2
edited by Mark Kohlmann
on 2022/10/16 17:23
on 2022/10/16 17:23
Change comment:
There is no comment for this version
To version 6.1
edited by Mark Kohlmann
on 2022/10/17 17:48
on 2022/10/17 17:48
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,22 @@ 1 -showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time. 1 +showrunner™ is a commercial lighting control and lighting management system. showrunner™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time. This documents is not a complete feature list and Chief Integrations reserves the right to make modifications at any time. 2 2 3 +{{box cssClass="floatinginfobox"}} 4 +(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %) 5 +**CONTENTS** 6 + 7 +{{toc start="4"/}} 8 +{{/box}} 9 + 10 +==== Key Capabilities ==== 11 + 12 +* Configuration driven with runtime configuration support enables rapid commissioning of commercial lighting systems 13 +* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements 14 +* Large native hardware support with the option to extend support to new hardware quickly and easily 15 +* Touchpanel and web based UIs cover users needs 16 +* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers 17 +* Floorplans with pinch, zoom, and insight! 18 +* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes 19 + 3 3 ==== Area Features ==== 4 4 5 5 * Lighting Loads ... ... @@ -194,6 +194,7 @@ 194 194 *** Scene Recall for Active and Inactive States 195 195 *** Demand Response 196 196 *** Actions for Active and Inactive States 214 +** Commonly used for FACP, override, demand response, and panic inputs 197 197 * Occupancy Sensors: 198 198 ** Occupancy configuration for CN and ZUMLINK occupancy sensors 199 199 ** 3rd Party and Non-System occupancy sensor support ... ... @@ -222,13 +222,25 @@ 222 222 ** Configurable thresholds 223 223 ** Assignable to individual loads for daylight harvesting 224 224 * Serial Interface 225 -** RS-232/422/484 243 +** RS-232/422/484 depending on hardware 226 226 ** Configurable Baud Rate and Com settings 227 -** Simple ASCII API for controlling/mon tioring245 +** Simple ASCII API for controlling/monitoring 228 228 ** Areas/Loads/Occupancy/Partition/Shades supported 229 229 * Shades 230 230 ** Support for Crestron shades/drapes 231 231 ** Support for many 3rd party shade and drape systems 250 +* Zum Wired 251 +** Edge logic operation in Zum App mode 252 +*** Override occupancy logic and use showrunner™ logic 253 +** Central logic in CNET mode 254 +** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes 255 +* Zum Wireless 256 +** Override keypad buttons (except buttons 5-6) 257 +** Edge logic operation 258 +** Override occupancy behavior with showrunner™ logic 259 +** Direct load control 260 +** Scene save 261 +* Support for configuring hardware symbol properties on Crestron hardware 232 232 233 233 ==== Energy Efficiency ==== 234 234 ... ... @@ -249,20 +249,36 @@ 249 249 ** HTTPS enforced 250 250 ** Auto session timeout 251 251 ** Login via username/password or PIN code 252 -** Support for Processor orinternal user database282 +** Support for Processor and internal user database with configurable priority or specify one exclusively 253 253 ** Best practices for password handling 254 254 * API using AWSv4 scheme for authentication per request for maximum security 285 +* Encrypted storage of all credentials and keys 255 255 256 -==== SystemFeatures ====287 +==== General Features ==== 257 257 258 258 * User configurable time zone, location, and current time 259 259 * Addressing and Verification of Cresnet devices by serial number 260 260 * Cresnet Device Serial Number capture 261 -* Configurable Global Actions with touchpanel trigger 262 262 * Extensive console command interface (CLI) 293 +* Simulate sensor and keypad inputs to test without hardware 294 +* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 295 +Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only. 263 263 264 - EventLog / Auditing297 +==== Diagnostics ==== 265 265 299 +* Provides diagnostic data when supported by hardware 300 +* Diagnostics available from load controllers all the way up to Cresnet bridges 301 +* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only 302 + 303 +==== Discovery ==== 304 + 305 +* Discover and automatically define Zum Wired hardware 306 +* Discover and automatically define Zum Wireless hardware 307 +* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number 308 +* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming 309 + 310 +==== Event Log ==== 311 + 266 266 * Central logging mechanism 267 267 * Messages time stamped 268 268 * CSV format ... ... @@ -289,13 +289,13 @@ 289 289 ** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem 290 290 ** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]] 291 291 * Global Actions 292 -** Allow m inimal or input triggered operations against the system338 +** Allow manual or input triggered operations against the system 293 293 ** Can be custom programmed at runtime 294 294 295 295 ==== User Interfaces ==== 296 296 297 297 * showrunner™ HUB 298 -** Web based 344 +** Web based, touch and mouse friendly design 299 299 ** Runs directly on the processor or VC-4 instance 300 300 ** HTTPS required 301 301 ** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience ... ... @@ -347,11 +347,49 @@ 347 347 *** Tags - Manage tags and association of tags with areas 348 348 *** User Management - Manage users/groups/API users 349 349 * Crestron TS/TSWs and Crestron App (iPad/iPhone/Android) 396 +** Area Control Screen 397 +*** Select Area (Can be disabled or restricted) 398 +*** Divide/Combine status, if divisible 399 +*** Occupancy/vacancy status, if has an occupancy sensor 400 +*** Individual load controls 401 +*** Dynamic white color temperature control, if supported 402 +*** RGB color picker, if load supported 403 +*** Scenes, up to 20, save with press and hold 404 +*** Master Raise/Lower 405 +*** Global Actions, if defined, can be hidden 406 +*** HVAC controls, if supported 407 +*** Shade controls, if supported 408 +*** Passcode protected, if enabled 409 +** Setup Screen 410 +*** Passcode protected, if enabled 411 +*** Area Configuration 412 +**** Area List 413 +**** Area Name, editable 414 +**** Load Configuration - Configure load control type and labeling, test fixture operation 415 +**** Occupancy Setup - Configure area occupancy behavior and occupancy settings 416 +**** Daylight Harvesting - Configure daylight harvesting settings per load/scene 417 +**** Scene Setup - Configure and add/delete scenes 418 +**** Properties - Configure area behavior settings 419 +**** Add/Delete areas 420 +*** Area Layout - Configure partition sensors and area assignments to partition sensors 421 +*** Crestron Integration - Configure EISCs 422 +*** Device Addressing - Address and verify Cresnet devices 423 +*** Keypad Configuration - Configure keypad type, area assignment, and enable status 424 +*** Load Hardware - Configure loads and load controllers 425 +*** Location and System Clock - View/Set system clock, site lat/lon, and timezone 426 +*** Occupancy Assignment - Assign occupancy sensors to loads/areas 427 +*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events) 428 +*** Security Settings - Enable/Disable/Change PIN codes 429 +*** Zum Integration - Configure export to Zum Floor Hub 430 +*** Help Screen - Support contact information, showrunner version list, and license status 431 +** Custom Logo option for splash screen 432 +** Optional floor plan area selection, zoom/pan are NOT supported, static image only 433 +** Optional partition control on floor plan screen 350 350 351 351 === Integrations === 352 352 353 -* AV Integration protocol via serial port 354 -* BAC Nnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron)437 +* AV Integration protocol via serial port, simple ASCII protocol with feedback 438 +* BACnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron) 355 355 ** Global 356 356 *** Override 357 357 *** Demand Response ... ... @@ -373,12 +373,12 @@ 373 373 **** Scenes 374 374 **** Occupied 375 375 **** Occupancy Sensor Enable 376 -* Crestron Fusion (Licensed Feature) 460 +* Crestron Fusion EM (Licensed Feature) 377 377 ** Scenes, Recall and Save 378 378 ** Load Control 379 379 ** Occupancy Status 380 380 ** Photocell 381 -* E-DMX Receiver465 +* e-DMX Receiver 382 382 ** SACN and/or Art-Net 383 383 ** Enable/Disable control for loads using e-DMX channel value 384 384 ** Map DMX to showrunner loads ... ... @@ -387,7 +387,7 @@ 387 387 ** Configurable rooms to export, change at runtime 388 388 ** Changes generate new RSD file at runtime that may be provided to the AV programmer 389 389 * HTTP REST API w/ Authorization 390 -* Lightweight API provides real-time control/feedback of hardwareusing CoAP474 +* Lightweight API provides real-time control/feedback using CoAP 391 391 * TCP Interface using simple ASCII commands, subscriptions supported 392 392 * UDP Receiver using simple ASCII commands 393 393 * Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature) ... ... @@ -402,7 +402,7 @@ 402 402 ** Partition Sensors (including setup for Cresnet sensors) 403 403 ** Photocells 404 404 405 -=== Reporting === 489 +==== Reporting ==== 406 406 407 407 ShowRunner provides a website via the processor's internal webserver with the following reports. All data is live at the time of the generation of the report. 408 408