Changes for page Features
Last modified by Scott Kohlmann on 2023/04/21 15:15
From version 5.1
edited by Mark Kohlmann
on 2022/10/14 23:43
on 2022/10/14 23:43
Change comment:
There is no comment for this version
To version 9.1
edited by Scott Kohlmann
on 2023/04/21 15:15
on 2023/04/21 15:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,5 +1,22 @@ 1 - showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time.1 +ShowRunnerCLC™ is a commercial lighting control and lighting management system. ShowRunnerCLC™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time. This document is not a complete feature list and Chief Integrations reserves the right to make modifications at any time. 2 2 3 +{{box cssClass="floatinginfobox"}} 4 +(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %) 5 +**CONTENTS** 6 + 7 +{{toc start="4"/}} 8 +{{/box}} 9 + 10 +==== Key Capabilities ==== 11 + 12 +* Configuration driven with runtime adaptability enables rapid commissioning of commercial lighting systems 13 +* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements 14 +* Large native hardware support with the ability to extend support to new hardware quickly and easily 15 +* Touchpanel and web based UIs cover users' needs 16 +* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers 17 +* Floorplans with pinch, zoom, and insight! 18 +* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes 19 + 3 3 ==== Area Features ==== 4 4 5 5 * Lighting Loads ... ... @@ -8,7 +8,7 @@ 8 8 * User configurable scene name, fade time, and load include by scene 9 9 * Individual scenes may be locked to prevent changing their settings 10 10 * Individual load control within an area 11 -* Selectareafrom touchpanel, areas can be restricted by panel28 +* Area selection from touchpanel, areas can be restricted by panel 12 12 * RGB controls for applicable fixtures, saved per scene 13 13 * Configurable Load Grouping for load consolidation including linked/group area loads 14 14 * Dynamic White/Circadian Rhythm CCT Control ... ... @@ -68,7 +68,7 @@ 68 68 * Demand Response Level 69 69 * Enable/Disable/Override states 70 70 * Option to ignore long fade times if the loads is off 71 -* Option recall last level 88 +* Option to recall last on level 72 72 * Individual daylight harvesting settings, enabled/disabled by scene 73 73 ** Open/closed loop 74 74 ** Min/Max levels ... ... @@ -88,13 +88,12 @@ 88 88 * DALI (DIN-DALI-2/ZUMNET-JBOX-DALI Legacy mode) 89 89 ** Addressing/Grouping/Driver Replacement for DALI. DALI groups are referenced by their controlled load simplifying addressing and replacement procedures. 90 90 91 -(% class="wikigeneratedid" %) 92 92 ==== Scheduling Features ==== 93 93 94 -* Algorithm based scheduling engine ensures predictable operation year after year with no need to specificallyspecify each day110 +* Algorithm based scheduling engine ensures predictable operation year after year with no need to define a system wide schedule per-day 95 95 * Area and/or Tag based schedules 96 96 * Individual global events or grouped events 97 -* showrunner™ HUB UI Features113 +* ShowRunnerCLC™ HUB UI Features 98 98 ** Day/Week/Month/Time Grid views display all events calculated by the scheduler engine 99 99 ** Tree based event/event groups 100 100 ** View Built-In Calendars and Groups ... ... @@ -134,6 +134,7 @@ 134 134 **** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter 135 135 *** Enable/Disable 136 136 ** Pre-loaded with US Federal and common non-Federal US Holidays 153 +** Support for additional algorithms available upon request 137 137 138 138 ==== Circadian Rhythm/Dynamic White ==== 139 139 ... ... @@ -151,7 +151,7 @@ 151 151 *** Static 152 152 *** Linear change over time 153 153 *** Sensor with configured CCT when sensor is out of range 154 -* Supported with 0-10V, DMX, and DALI 171 +* Supported with 0-10V, DMX, and DALI. Additional support via APIs 155 155 156 156 ==== Supported Hardware Features ==== 157 157 ... ... @@ -167,9 +167,9 @@ 167 167 ** Support for some Crestron Thermostats, more can be added as needed 168 168 ** Support for some 3rd party systems, more can be added as needed 169 169 * Keypads 170 -** Support for common fixed configurations, user assignable at runtime 187 +** Support for common fixed configurations, user assignable at runtime. Includes all standard Crestron SpecsBuilder types. 171 171 ** Custom keypads with configurable actions per button at runtime 172 -*** Graphic based programming using showrunner™HUB189 +*** Graphic based programming using ShowRunnerHUB™ UI 173 173 *** Master raise/lower button support allows assignment of currently selected load/shade/area/etc 174 174 *** Custom button layouts w/ labels to assist with generating engravings 175 175 ** Flexible Templating Engine ... ... @@ -183,7 +183,7 @@ 183 183 ** Flip raise/lower on common keypad types 184 184 ** Configurable hold time support, done in software if not supported by hardware 185 185 ** Configurable double tap time support if supported by hardware 186 -** Simulate keypads from showrunner™ HUB UI or console203 +** Simulate keypads from ShowRunnerCLC™ HUB UI or console 187 187 ** Direct load mapping for some common keypads 188 188 * Keyswitch/Contact Closure Inputs 189 189 ** Supports all versiport and digital inputs ... ... @@ -194,12 +194,13 @@ 194 194 *** Scene Recall for Active and Inactive States 195 195 *** Demand Response 196 196 *** Actions for Active and Inactive States 214 +** Commonly used for FACP, override, demand response, and panic inputs 197 197 * Occupancy Sensors: 198 198 ** Occupancy configuration for CN and ZUMLINK occupancy sensors 199 199 ** 3rd Party and Non-System occupancy sensor support 200 200 ** Occupancy/Vacancy/Disabled/Use Hardware Logic modes, user configurable 201 201 ** Configure scenes recalled by area for occupancy and vacancy states 202 -** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance 220 +** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance (open office 600sqft) 203 203 ** User configurable assignment of sensor to area(s) and load(s) 204 204 ** Occupancy sensors may feed data to multiple areas and loads 205 205 ** Last occupied and vacant times recorded ... ... @@ -213,9 +213,10 @@ 213 213 ** Support for divisible areas 214 214 ** GLS-PART-CN with adjustable sensitivity 215 215 ** 3rd party sensor support via hardware inputs 216 -** User configurable Auto ,Combined,and Divided234 +** User configurable Auto (use sensor) with manual override for Combined and Divided 217 217 ** Filtering to ignore noisy partition sensors 218 -** Change count and last change recorded 236 +** Change count and last change recorded help troubleshoot 237 +** Hardware not required, may be setup as a virtual sensor 219 219 * Photocell 220 220 ** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior) 221 221 ** Configurable coefficient ... ... @@ -222,13 +222,25 @@ 222 222 ** Configurable thresholds 223 223 ** Assignable to individual loads for daylight harvesting 224 224 * Serial Interface 225 -** RS-232/422/484 244 +** RS-232/422/484 depending on hardware 226 226 ** Configurable Baud Rate and Com settings 227 -** Simple ASCII API for controlling/mon tioring246 +** Simple ASCII API for controlling/monitoring 228 228 ** Areas/Loads/Occupancy/Partition/Shades supported 229 229 * Shades 230 230 ** Support for Crestron shades/drapes 231 231 ** Support for many 3rd party shade and drape systems 251 +* Zum Wired 252 +** Edge logic operation in Zum App mode 253 +*** Override occupancy logic and use ShowRunnerCLC™ logic 254 +** Central logic in CNET mode 255 +** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes 256 +* Zum Wireless 257 +** Override keypad buttons (except buttons 5-6) 258 +** Edge logic operation 259 +** Override occupancy behavior with ShowRunnerCLC™ logic 260 +** Direct load control 261 +** Scene save 262 +* Support for configuring hardware symbol properties on Crestron hardware 232 232 233 233 ==== Energy Efficiency ==== 234 234 ... ... @@ -241,7 +241,7 @@ 241 241 ==== Security ==== 242 242 243 243 * Touchscreens: Global User and Technician Passcodes, user configurable. 244 -* showrunner™ HUB275 +* ShowRunnerCLC™ HUB 245 245 ** Role Based permissions by Group 246 246 ** Granular Create, Edit, View, Delete, and Execute permissions by Role 247 247 ** Users and API Users assignable to groups ... ... @@ -249,36 +249,69 @@ 249 249 ** HTTPS enforced 250 250 ** Auto session timeout 251 251 ** Login via username/password or PIN code 252 -** Support for Processor orinternal user database283 +** Support for Processor and internal user database with configurable priority or specify one exclusively 253 253 ** Best practices for password handling 254 254 * API using AWSv4 scheme for authentication per request for maximum security 286 +* Encrypted storage of all credentials and keys 255 255 256 -==== SystemFeatures ====288 +==== General Features ==== 257 257 258 258 * User configurable time zone, location, and current time 259 259 * Addressing and Verification of Cresnet devices by serial number 260 260 * Cresnet Device Serial Number capture 261 -* Configurable Global Actions with touchpanel trigger 262 262 * Extensive console command interface (CLI) 294 +* Simulate sensor and keypad inputs to test without hardware 295 +* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 296 +Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only. 263 263 264 -(% class="wikigeneratedid" %) 298 +==== Diagnostics ==== 299 + 300 +* Provides diagnostic data when supported by hardware 301 +* Diagnostics available from load controllers all the way up to Cresnet bridges 302 +* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only 303 + 304 +==== Discovery ==== 305 + 306 +* Discover and automatically define Zum Wired hardware 307 +* Discover and automatically define Zum Wireless hardware 308 +* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number 309 +* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming 310 + 311 +==== Event Log ==== 312 + 313 +* Central logging mechanism 314 +* Messages time stamped 315 +* CSV format 316 +* Multiple logging levels: Critical, Error, Warning, Information, Debug, Trace 317 +* Filter by logging level 318 +* Filter by source object 319 +* Filter by GlobalId 320 +* Trace option allows tracking the triggering event through execution 321 +* Thread option allows tracking of the thread executing 322 +* Logging to console 323 +* Logging to file 324 +* Logging to remote syslog (via processor) 325 +* Heartbeat option with configurable interval 326 +* Debugging writes to the event log 327 +* Global Enable flag 328 + 265 265 ==== Extensibility ==== 266 266 267 267 * Actions 268 -** Logic objects exist on showrunner™ objects332 +** Logic objects exist on ShowRunnerCLC™ objects 269 269 ** Functionality can be triggered via APIs 270 -** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within showrunner™334 +** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within ShowRunnerCLC™ 271 271 * Extensions 272 -** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem336 +** Extension model allows customization and additional functionality to be added to the ShowRunnerCLC™ ecosystem 273 273 ** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]] 274 274 * Global Actions 275 -** Allow m inimal or input triggered operations against the system339 +** Allow manual or input triggered operations against the system 276 276 ** Can be custom programmed at runtime 277 277 278 278 ==== User Interfaces ==== 279 279 280 -* showrunner™HUB281 -** Web based 344 +* ShowRunnerHUB™ 345 +** Web based, touch and mouse friendly design 282 282 ** Runs directly on the processor or VC-4 instance 283 283 ** HTTPS required 284 284 ** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience ... ... @@ -322,19 +322,57 @@ 322 322 *** Hardware Management - Tree view of Ethernet, Cresnet, and RF topologies 323 323 *** File Management - Manage config, license, currently active config, and backup/restore operations 324 324 *** Global Actions - Add/Delete/Configure 325 -*** Integrations - Manage integrations with other showrunner™ systems389 +*** Integrations - Manage integrations with other ShowRunnerCLC™ systems 326 326 *** Keypad Configuration - Configure keypads 327 -*** Maps - Add floorplan images 391 +*** Maps - Add/Manage floorplan images 328 328 *** Network - DHCP Server (for processors without routers only) 329 329 *** System Settings - Manage various system settings 330 330 *** Tags - Manage tags and association of tags with areas 331 331 *** User Management - Manage users/groups/API users 332 332 * Crestron TS/TSWs and Crestron App (iPad/iPhone/Android) 397 +** Area Control Screen 398 +*** Select Area (Can be disabled or restricted) 399 +*** Divide/Combine status, if divisible 400 +*** Occupancy/vacancy status, if has an occupancy sensor 401 +*** Individual load controls 402 +*** Dynamic white color temperature control, if supported 403 +*** RGB color picker, if load supported 404 +*** Scenes, up to 20, save with press and hold 405 +*** Master Raise/Lower 406 +*** Global Actions, if defined, can be hidden 407 +*** HVAC controls, if supported 408 +*** Shade controls, if supported 409 +*** Passcode protected, if enabled 410 +** Setup Screen 411 +*** Passcode protected, if enabled 412 +*** Area Configuration 413 +**** Area List 414 +**** Area Name, editable 415 +**** Load Configuration - Configure load control type and labeling, test fixture operation 416 +**** Occupancy Setup - Configure area occupancy behavior and occupancy settings 417 +**** Daylight Harvesting - Configure daylight harvesting settings per load/scene 418 +**** Scene Setup - Configure and add/delete scenes 419 +**** Properties - Configure area behavior settings 420 +**** Add/Delete areas 421 +*** Area Layout - Configure partition sensors and area assignments to partition sensors 422 +*** Crestron Integration - Configure EISCs 423 +*** Device Addressing - Address and verify Cresnet devices 424 +*** Keypad Configuration - Configure keypad type, area assignment, and enable status 425 +*** Load Hardware - Configure loads and load controllers 426 +*** Location and System Clock - View/Set system clock, site lat/lon, and timezone 427 +*** Occupancy Assignment - Assign occupancy sensors to loads/areas 428 +*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events) 429 +*** Security Settings - Enable/Disable/Change PIN codes 430 +*** Zum Integration - Configure export to Zum Floor Hub 431 +*** Help Screen - Support contact information, ShowRunnerCLC™ version list, and license status 432 +** Custom Logo option for splash screen 433 +** Optional floor plan area selection, zoom/pan are NOT supported, static image only 434 +** Optional partition control on floor plan screen 333 333 334 334 === Integrations === 335 335 336 -* AV Integration protocol via serial port 337 -* BAC Nnet Support for integration of Areas, Loads (Licensed Feature, bothshowrunner and Crestron)438 +* AV Integration protocol via serial port, simple ASCII protocol with feedback 439 +* BACnet Support for integration of Areas, Loads (Licensed Feature, both ShowRunnerCLC™ and Crestron) 338 338 ** Global 339 339 *** Override 340 340 *** Demand Response ... ... @@ -342,7 +342,7 @@ 342 342 *** Alarm 343 343 *** System Normal/After Hours 344 344 ** Area Specific 345 -*** showrunner™ Mode447 +*** ShowRunnerCLC™ Mode 346 346 **** Occupancy Status 347 347 **** Occupancy Enable 348 348 **** Scenes ... ... @@ -356,25 +356,25 @@ 356 356 **** Scenes 357 357 **** Occupied 358 358 **** Occupancy Sensor Enable 359 -* Crestron Fusion (Licensed Feature) 461 +* Crestron Fusion EM (Licensed Feature) 360 360 ** Scenes, Recall and Save 361 361 ** Load Control 362 362 ** Occupancy Status 363 363 ** Photocell 364 -* E-DMX Receiver466 +* e-DMX Receiver 365 365 ** SACN and/or Art-Net 366 366 ** Enable/Disable control for loads using e-DMX channel value 367 -** Map DMX to showrunner loads469 +** Map DMX to ShowRunnerCLC™ loads 368 368 * EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client) 369 369 ** Configurable IP address and IP-ID, change at runtime 370 370 ** Configurable rooms to export, change at runtime 371 371 ** Changes generate new RSD file at runtime that may be provided to the AV programmer 372 372 * HTTP REST API w/ Authorization 373 -* Lightweight API provides real-time control/feedback of hardwareusing CoAP475 +* Lightweight API provides real-time control/feedback using CoAP 374 374 * TCP Interface using simple ASCII commands, subscriptions supported 375 375 * UDP Receiver using simple ASCII commands 376 -* Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature)377 -* Remote hardware support from neighbor ShowRunner System: 478 +* Zum Floor Hub Support for integration, Export ShowRunnerCLC™ areas to the Floor Hub (Licensed Feature) 479 +* Remote hardware support from neighbor ShowRunnerCLC™ System: 378 378 ** Allows a central ShowRunner system to integrate edge processors 379 379 ** AV Serial Interface 380 380 ** Loads ... ... @@ -385,7 +385,7 @@ 385 385 ** Partition Sensors (including setup for Cresnet sensors) 386 386 ** Photocells 387 387 388 -=== Reporting === 490 +==== Reporting ==== 389 389 390 390 ShowRunner provides a website via the processor's internal webserver with the following reports. All data is live at the time of the generation of the report. 391 391