Changes for page Features
Last modified by Scott Kohlmann on 2023/04/21 15:15
From version 4.1
edited by Mark Kohlmann
on 2020/09/02 21:04
on 2020/09/02 21:04
Change comment:
There is no comment for this version
To version 9.1
edited by Scott Kohlmann
on 2023/04/21 15:15
on 2023/04/21 15:15
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,12 +1,31 @@ 1 -S HOWRUNNER™ has a large number of features focused on the needs of the commercial lighting market.1 +ShowRunnerCLC™ is a commercial lighting control and lighting management system. ShowRunnerCLC™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time. This document is not a complete feature list and Chief Integrations reserves the right to make modifications at any time. 2 2 3 -=== Features === 3 +{{box cssClass="floatinginfobox"}} 4 +(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %) 5 +**CONTENTS** 4 4 5 -* Lighting Controls grouped into Areas 6 -* Scene recall and master raise/lower by area 7 -* User configurable scene name, fade time, and load include by area 7 +{{toc start="4"/}} 8 +{{/box}} 9 + 10 +==== Key Capabilities ==== 11 + 12 +* Configuration driven with runtime adaptability enables rapid commissioning of commercial lighting systems 13 +* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements 14 +* Large native hardware support with the ability to extend support to new hardware quickly and easily 15 +* Touchpanel and web based UIs cover users' needs 16 +* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers 17 +* Floorplans with pinch, zoom, and insight! 18 +* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes 19 + 20 +==== Area Features ==== 21 + 22 +* Lighting Loads 23 +* Scene recall 24 +* Master raise/lower 25 +* User configurable scene name, fade time, and load include by scene 26 +* Individual scenes may be locked to prevent changing their settings 8 8 * Individual load control within an area 9 -* Selectareafrom touchpanel, areas can be restricted by panel28 +* Area selection from touchpanel, areas can be restricted by panel 10 10 * RGB controls for applicable fixtures, saved per scene 11 11 * Configurable Load Grouping for load consolidation including linked/group area loads 12 12 * Dynamic White/Circadian Rhythm CCT Control ... ... @@ -13,80 +13,452 @@ 13 13 ** CCT Control per area for applicable fixtures 14 14 ** Global schedule for CCT, astronomical and/or fixed schedules 15 15 ** Manual CCT override per area 35 +* Demand Response with ability to exclude area from Demand Response event 36 +* Configurable load grouping allows aggregation of loads to a single slider per group, can include linked areas 37 +* HVAC Control 38 +* Shades 39 +* Occupancy Features 40 +** Occupancy Modes 41 +*** Occupancy 42 +*** Vacancy 43 +*** Disabled 44 +*** Use Hardware Logic (if supported by edge controller) 45 +** Extend occupancy timeout by user specified seconds, can be scheduled 46 +** Configurable occupied and vacant scenes, scheduled 47 +** Configurable grace occupancy support without needing support in hardware 48 +* After Hours support for automatic shutoff after configurable timeout w/ alerting 49 +* Parent Area feature allows one area to trickle down scene recall and raise/lower (if enabled) 50 +* Last Scene Recall timestamp and triggering action recorded 51 +* Organized in a node tree with multiple depths 52 + 53 +==== Load Features ==== 54 + 55 +* Dynamically assigned/unassigned at runtime to areas 56 +* Supported load types 57 +** Single Channel 58 +** Dynamic White/CCT 59 +*** Warm/Cool 60 +*** Intensity/CCT 61 +*** DALI Type 8 62 +*** Pharos Dynamic White 63 +** RGB/W/A 64 +*** Color Picker 65 +*** W/A channels can be controlled individually or mixed (Pharos) 66 +* Supported load behaviors 67 +** Dimmable 68 +** Switched 69 +** Plug Load 70 +* Dimming Curves 71 +** Unaffected 72 +** Linear 73 +** Linear No Zero Pass (support for EM lights that are not allowed to turn off i.e. Chicago 10%) 74 +** Logarithmic 75 +** Non Dim 76 +** S Curve 77 +** Soft Linear 78 +** Square 79 +** Always On 80 +** Inverse Log 81 +** Custom based on input output ranges 82 +* Min/Mix Trim, performed in hardware if supported 83 +* Override Level, performed in hardware if supported 84 +* Unoccupied Level 85 +* Demand Response Level 86 +* Enable/Disable/Override states 87 +* Option to ignore long fade times if the loads is off 88 +* Option to recall last on level 89 +* Individual daylight harvesting settings, enabled/disabled by scene 90 +** Open/closed loop 91 +** Min/Max levels 92 +** Sensitivity 93 +** Fade time 94 +* Loads may track other loads 95 +* Remap channels for unusual fixture channel mappings 96 +* Raise/lower, performed with software fade engine if not supported by hardware 97 +* Dynamic White/Circadian Rhythm CCT 16 16 ** Custom CCT curves per load or default algorithm 17 17 ** Min/Max CCT per load 18 18 ** Support for Warm/Cool or Intensity/CCT fixture types 19 19 ** Configurable automatic fixture shut off if outside CCT range 20 -** Crestron GLS-LCCT sensor integration for daylight tracking 21 -* Sophisticated Scheduling Engine 22 -** Configurable Actions by Area 23 -*** Scene 24 -**** Override Scene Fade Time 25 -*** Change Keypad State (Enable/Disable/Disable Off) 26 -*** Change Occupancy Mode (Occupancy/Vacancy/Disable/Last) 27 -*** Switch between Normal and After Hours (for Timeout) 28 -*** Change CCT Mode (Auto/Manual) 29 -*** Assign Manual CCT 30 -*** Extend Occupancy Timeout 31 -*** Change Scenes Recalled by Occupied/Vacant/On/Off 32 -*** Shade Command (Open/Close) 33 -*** Plug Load Mode (Off/On/Auto) 34 -** Copy Actions from Area to Area 35 -** AM, PM, and Astronomical (Sunrise/Sunset) Time References 36 -** Event Verification by Date in real-time with month calendar view and event description 37 -** Advanced Scheduling Feature (Licensed) 38 -*** Event Include and/or Exclude by Calendar(s) and/or Calendar Group(s) 39 -*** Calendar Groups consist of one or more Calendars 40 -*** Calendars can be based on a Date Range or Date Pattern 41 -*** Calendar Properties: 42 -**** Date Range: 43 -***** Start and End Dates or Specific Dates selected using Date Picker 44 -***** Does this Recur Annually 45 -**** Date Pattern: 46 -***** Year - Restrict to specific year or none 47 -***** Month - Restrict to specific Month(s) or none 48 -***** Week - Restrict to specific Week of the month or none 49 -***** Week Day - Restrict to specific day of the week or none 50 -***** Day - Restrict to a specific day of the month or none 51 -***** Optional: Offset - Offset date based on restrictions 52 -***** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter 53 -**** Enable/Disable 54 -*** Pre-loaded with US Federal and common non-Federal US Holidays 102 +** Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 103 +* Load flashing for identification 104 +* Verified timestamp option 105 +* DALI (DIN-DALI-2/ZUMNET-JBOX-DALI Legacy mode) 106 +** Addressing/Grouping/Driver Replacement for DALI. DALI groups are referenced by their controlled load simplifying addressing and replacement procedures. 107 + 108 +==== Scheduling Features ==== 109 + 110 +* Algorithm based scheduling engine ensures predictable operation year after year with no need to define a system wide schedule per-day 111 +* Area and/or Tag based schedules 112 +* Individual global events or grouped events 113 +* ShowRunnerCLC™ HUB UI Features 114 +** Day/Week/Month/Time Grid views display all events calculated by the scheduler engine 115 +** Tree based event/event groups 116 +** View Built-In Calendars and Groups 117 +** Create/Edit/Delete Custom Calendars and Groups 118 +* Execute last event on startup (configurable) to bring system in to correct state 119 +* Configurable Actions 120 +** Scene w/ option to override fade time 121 +** Change Keypad State (Enable/Disable/Disable Off) 122 +** Change Occupancy Mode (Occupancy/Vacancy/Disable/Last/Use Hardware) 123 +** Switch between Normal and After Hours (for Timeout) 124 +** Change CCT Mode (Auto/Manual) 125 +** Assign Manual CCT 126 +** Extend Occupancy Timeout setting 127 +** Change Scenes Recalled by Occupied/Vacant/On/Off 128 +** Shade Command (Open/Close) 129 +** Plug Load Mode (Off/On/Auto) 130 +* Copy Actions from Area to Area 131 +* AM, PM, and Relative to Astronomical (Sunrise/Sunset) Time References 132 +* Event Verification by Date in real-time with month calendar view and event description 133 +* Require a scene to be active before recalling the scheduled scene (optional) 134 +* Advanced Scheduling Feature (Licensed) 135 +** Event Include and/or Exclude by Calendar(s) and/or Calendar Group(s) 136 +** Calendar Groups consist of one or more Calendars 137 +** Calendars can be based on a Date Range or Date Pattern 138 +** Calendar Properties: 139 +*** Date Range: 140 +**** Start and End Dates 141 +**** Specific Dates selected using Date Picker 142 +**** Recur Annually Option 143 +*** Date Pattern: 144 +**** Year - Restrict to specific year or none 145 +**** Month - Restrict to specific Month(s) or none 146 +**** Week - Restrict to specific Week of the month or none 147 +**** Week Day - Restrict to specific day of the week or none 148 +**** Day - Restrict to a specific day of the month or none 149 +**** Optional: Offset - Offset date based on restrictions 150 +**** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter 151 +*** Enable/Disable 152 +** Pre-loaded with US Federal and common non-Federal US Holidays 153 +** Support for additional algorithms available upon request 154 + 155 +==== Circadian Rhythm/Dynamic White ==== 156 + 157 +* Global system CCT Level 158 +* Override CCT per area by scene or manually 159 +* Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 160 +* Time period based 161 +** Time References for start and end of period 162 +*** AM/PM 163 +*** Relative to 164 +**** Sunrise 165 +**** Sunset 166 +**** Solar Noon 167 +** Each time period can have the following setting for CCT 168 +*** Static 169 +*** Linear change over time 170 +*** Sensor with configured CCT when sensor is out of range 171 +* Supported with 0-10V, DMX, and DALI. Additional support via APIs 172 + 173 +==== Supported Hardware Features ==== 174 + 175 +Virtually the entire Crestron lighting product line is supported along with several 3rd party products 176 + 177 +* Common Settings to all devices 178 +** Contractor Label 179 +** Name 180 +** GlobalId 181 +** UniqueId (GUID) 182 +* HVAC 183 +** Temperature control by area 184 +** Support for some Crestron Thermostats, more can be added as needed 185 +** Support for some 3rd party systems, more can be added as needed 55 55 * Keypads 56 -** Support for common fixed configurations, user assignable 57 -** Custom keypads with configurable actions per button 187 +** Support for common fixed configurations, user assignable at runtime. Includes all standard Crestron SpecsBuilder types. 188 +** Custom keypads with configurable actions per button at runtime 189 +*** Graphic based programming using ShowRunnerHUB™ UI 190 +*** Master raise/lower button support allows assignment of currently selected load/shade/area/etc 191 +*** Custom button layouts w/ labels to assist with generating engravings 192 +** Flexible Templating Engine 193 +*** Create common keypad templates 194 +*** Apply keypad templates to individual keypads 195 +**** Remap hardware when template is applied 196 +**** Optionally exclude specific hardware and/or buttons 58 58 ** User configurable area to control 198 +** Enable/Disable/Disable Off states 199 +** Prevent disable option 200 +** Flip raise/lower on common keypad types 201 +** Configurable hold time support, done in software if not supported by hardware 202 +** Configurable double tap time support if supported by hardware 203 +** Simulate keypads from ShowRunnerCLC™ HUB UI or console 204 +** Direct load mapping for some common keypads 205 +* Keyswitch/Contact Closure Inputs 206 +** Supports all versiport and digital inputs 207 +** Maintained and Momentary supported 208 +** Feedback output supported 209 +** Functions 210 +*** Override 211 +*** Scene Recall for Active and Inactive States 212 +*** Demand Response 213 +*** Actions for Active and Inactive States 214 +** Commonly used for FACP, override, demand response, and panic inputs 59 59 * Occupancy Sensors: 60 -** Occupancy configuration for CN typeoccupancy sensors216 +** Occupancy configuration for CN and ZUMLINK occupancy sensors 61 61 ** 3rd Party and Non-System occupancy sensor support 62 -** Occupancy/Vacancy/Disabled modes, user configurable 218 +** Occupancy/Vacancy/Disabled/Use Hardware Logic modes, user configurable 63 63 ** Configure scenes recalled by area for occupancy and vacancy states 64 -** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance 220 +** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance (open office 600sqft) 65 65 ** User configurable assignment of sensor to area(s) and load(s) 66 66 ** Occupancy sensors may feed data to multiple areas and loads 223 +** Last occupied and vacant times recorded 224 +* Output Signal 225 +** Logic object capable of triggering additional logic 226 +** Can trigger physical outputs via versiports/IOs 227 +** Supports conditional logic 228 +** Independent actions for active/inactive states 229 +** Configurable delays for active/inactive execution 67 67 * Partition sensors 68 68 ** Support for divisible areas 69 69 ** GLS-PART-CN with adjustable sensitivity 70 -** 3rd party sensor support via versiport input 71 -** User configurable Auto, Combined, and Divided modes to override occ sensor, activated by UI or keypad 72 -* Maintained and Momentary Keyswitch/FACP/Override Input for scene recall or override activation 233 +** 3rd party sensor support via hardware inputs 234 +** User configurable Auto (use sensor) with manual override for Combined and Divided 235 +** Filtering to ignore noisy partition sensors 236 +** Change count and last change recorded help troubleshoot 237 +** Hardware not required, may be setup as a virtual sensor 238 +* Photocell 239 +** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior) 240 +** Configurable coefficient 241 +** Configurable thresholds 242 +** Assignable to individual loads for daylight harvesting 243 +* Serial Interface 244 +** RS-232/422/484 depending on hardware 245 +** Configurable Baud Rate and Com settings 246 +** Simple ASCII API for controlling/monitoring 247 +** Areas/Loads/Occupancy/Partition/Shades supported 248 +* Shades 249 +** Support for Crestron shades/drapes 250 +** Support for many 3rd party shade and drape systems 251 +* Zum Wired 252 +** Edge logic operation in Zum App mode 253 +*** Override occupancy logic and use ShowRunnerCLC™ logic 254 +** Central logic in CNET mode 255 +** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes 256 +* Zum Wireless 257 +** Override keypad buttons (except buttons 5-6) 258 +** Edge logic operation 259 +** Override occupancy behavior with ShowRunnerCLC™ logic 260 +** Direct load control 261 +** Scene save 262 +* Support for configuring hardware symbol properties on Crestron hardware 263 + 264 +==== Energy Efficiency ==== 265 + 73 73 * Demand Response/Load Shedding 74 74 ** Automatic via sensor input 75 -** Manually via keypad 76 -* Configurable maximum demand response level by load 77 -* Dynamic addition/deletion/assignment/configuration of loads 78 -* Dynamic addition/deletion of areas 79 -* User editable labeling of areas, loads, keypads, occupancy sensors, and schedules 80 -* Daylight Harvesting sensor to load assignment and settings adjustment 81 -* Global User and Technician Passcodes, user configurable. 268 +** Manually via user input 269 +* Calculated or Measured Power (Watts) 270 +* Energy Efficiency visualization on floorplan 271 + 272 +==== Security ==== 273 + 274 +* Touchscreens: Global User and Technician Passcodes, user configurable. 275 +* ShowRunnerCLC™ HUB 276 +** Role Based permissions by Group 277 +** Granular Create, Edit, View, Delete, and Execute permissions by Role 278 +** Users and API Users assignable to groups 279 +** Restrict Group by area and tag 280 +** HTTPS enforced 281 +** Auto session timeout 282 +** Login via username/password or PIN code 283 +** Support for Processor and internal user database with configurable priority or specify one exclusively 284 +** Best practices for password handling 285 +* API using AWSv4 scheme for authentication per request for maximum security 286 +* Encrypted storage of all credentials and keys 287 + 288 +==== General Features ==== 289 + 82 82 * User configurable time zone, location, and current time 83 -* Addressing/Grouping/Driver Replacement for DALI. DALI groups are referenced by their controlled load simplifying addressing and replacement procedures. 84 84 * Addressing and Verification of Cresnet devices by serial number 85 85 * Cresnet Device Serial Number capture 86 -* Configurable Global Actions with touchpanel trigger 87 -* User configurable Crestron EISC Integration with ability to change IP Address and IP-ID of remote Crestron system as well as Areas shared on the fly. RSD file is automatically generated and link is provided for downloading of RSD file. 88 -* Remote hardware support from neighbor ShowRunner System: 89 -** Allows a master ShowRunner system to integrate slave processors 293 +* Extensive console command interface (CLI) 294 +* Simulate sensor and keypad inputs to test without hardware 295 +* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 296 +Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only. 297 + 298 +==== Diagnostics ==== 299 + 300 +* Provides diagnostic data when supported by hardware 301 +* Diagnostics available from load controllers all the way up to Cresnet bridges 302 +* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only 303 + 304 +==== Discovery ==== 305 + 306 +* Discover and automatically define Zum Wired hardware 307 +* Discover and automatically define Zum Wireless hardware 308 +* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number 309 +* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming 310 + 311 +==== Event Log ==== 312 + 313 +* Central logging mechanism 314 +* Messages time stamped 315 +* CSV format 316 +* Multiple logging levels: Critical, Error, Warning, Information, Debug, Trace 317 +* Filter by logging level 318 +* Filter by source object 319 +* Filter by GlobalId 320 +* Trace option allows tracking the triggering event through execution 321 +* Thread option allows tracking of the thread executing 322 +* Logging to console 323 +* Logging to file 324 +* Logging to remote syslog (via processor) 325 +* Heartbeat option with configurable interval 326 +* Debugging writes to the event log 327 +* Global Enable flag 328 + 329 +==== Extensibility ==== 330 + 331 +* Actions 332 +** Logic objects exist on ShowRunnerCLC™ objects 333 +** Functionality can be triggered via APIs 334 +** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within ShowRunnerCLC™ 335 +* Extensions 336 +** Extension model allows customization and additional functionality to be added to the ShowRunnerCLC™ ecosystem 337 +** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]] 338 +* Global Actions 339 +** Allow manual or input triggered operations against the system 340 +** Can be custom programmed at runtime 341 + 342 +==== User Interfaces ==== 343 + 344 +* ShowRunnerHUB™ 345 +** Web based, touch and mouse friendly design 346 +** Runs directly on the processor or VC-4 instance 347 +** HTTPS required 348 +** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience 349 +** Node Tree 350 +*** Organize areas in logical locations based on physical topology 351 +*** Searchable, only shows matching areas 352 +** Floorplans 353 +*** Assigned to a node, multiple floor plans are supported 354 +*** Pinch zoom/touch pan 355 +*** User provided floorplan 356 +*** Draw directly on floorplan for areas and objects 357 +**** Areas 358 +**** Loads 359 +**** Partitions 360 +**** Occupancy Sensors 361 +**** Keypads 362 +**** Photocells 363 +*** Crestron product line icons area available to match the installed sensor 364 +*** Interactive control screens depending on clicked object 365 +*** Multiple different views help visualize data 366 +**** Area View - Shows areas with user selected colors 367 +**** Tags View - Shows areas based on their assigned tag 368 +**** Occupancy View - Shows areas based on their current occupancy status and how recently that status changed 369 +**** Intensity View - Shows areas shaded based on the current overall light intensity 370 +**** Energy View - Shows areas shaded based on the areas current energy efficiency from efficient to inefficient 371 +*** Automatic navigation to area when selected from the node tree 372 +*** Fullscreen view 373 +** Schedule 374 +*** See [[Scheduling Features>>doc:||anchor="Scheduling Features"]] for more info 375 +** Reports 376 +*** Interactive data 377 +**** Area Loads 378 +**** Area Scenes 379 +**** Areas 380 +**** Cresnet (Query) 381 +**** Device Status 382 +**** Events 383 +**** Keypads 384 +** Setup 385 +*** Device Diagnostic - Show Diagnostic data from supported devices 386 +*** Hardware Management - Tree view of Ethernet, Cresnet, and RF topologies 387 +*** File Management - Manage config, license, currently active config, and backup/restore operations 388 +*** Global Actions - Add/Delete/Configure 389 +*** Integrations - Manage integrations with other ShowRunnerCLC™ systems 390 +*** Keypad Configuration - Configure keypads 391 +*** Maps - Add/Manage floorplan images 392 +*** Network - DHCP Server (for processors without routers only) 393 +*** System Settings - Manage various system settings 394 +*** Tags - Manage tags and association of tags with areas 395 +*** User Management - Manage users/groups/API users 396 +* Crestron TS/TSWs and Crestron App (iPad/iPhone/Android) 397 +** Area Control Screen 398 +*** Select Area (Can be disabled or restricted) 399 +*** Divide/Combine status, if divisible 400 +*** Occupancy/vacancy status, if has an occupancy sensor 401 +*** Individual load controls 402 +*** Dynamic white color temperature control, if supported 403 +*** RGB color picker, if load supported 404 +*** Scenes, up to 20, save with press and hold 405 +*** Master Raise/Lower 406 +*** Global Actions, if defined, can be hidden 407 +*** HVAC controls, if supported 408 +*** Shade controls, if supported 409 +*** Passcode protected, if enabled 410 +** Setup Screen 411 +*** Passcode protected, if enabled 412 +*** Area Configuration 413 +**** Area List 414 +**** Area Name, editable 415 +**** Load Configuration - Configure load control type and labeling, test fixture operation 416 +**** Occupancy Setup - Configure area occupancy behavior and occupancy settings 417 +**** Daylight Harvesting - Configure daylight harvesting settings per load/scene 418 +**** Scene Setup - Configure and add/delete scenes 419 +**** Properties - Configure area behavior settings 420 +**** Add/Delete areas 421 +*** Area Layout - Configure partition sensors and area assignments to partition sensors 422 +*** Crestron Integration - Configure EISCs 423 +*** Device Addressing - Address and verify Cresnet devices 424 +*** Keypad Configuration - Configure keypad type, area assignment, and enable status 425 +*** Load Hardware - Configure loads and load controllers 426 +*** Location and System Clock - View/Set system clock, site lat/lon, and timezone 427 +*** Occupancy Assignment - Assign occupancy sensors to loads/areas 428 +*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events) 429 +*** Security Settings - Enable/Disable/Change PIN codes 430 +*** Zum Integration - Configure export to Zum Floor Hub 431 +*** Help Screen - Support contact information, ShowRunnerCLC™ version list, and license status 432 +** Custom Logo option for splash screen 433 +** Optional floor plan area selection, zoom/pan are NOT supported, static image only 434 +** Optional partition control on floor plan screen 435 + 436 +=== Integrations === 437 + 438 +* AV Integration protocol via serial port, simple ASCII protocol with feedback 439 +* BACnet Support for integration of Areas, Loads (Licensed Feature, both ShowRunnerCLC™ and Crestron) 440 +** Global 441 +*** Override 442 +*** Demand Response 443 +*** Device Offline Count 444 +*** Alarm 445 +*** System Normal/After Hours 446 +** Area Specific 447 +*** ShowRunnerCLC™ Mode 448 +**** Occupancy Status 449 +**** Occupancy Enable 450 +**** Scenes 451 +**** Loads 452 +**** Photocell Level 453 +**** Overall Intensity 454 +**** Power (watts) 455 +*** Zum Hub Emulation Mode 456 +**** Online 457 +**** On 458 +**** Scenes 459 +**** Occupied 460 +**** Occupancy Sensor Enable 461 +* Crestron Fusion EM (Licensed Feature) 462 +** Scenes, Recall and Save 463 +** Load Control 464 +** Occupancy Status 465 +** Photocell 466 +* e-DMX Receiver 467 +** SACN and/or Art-Net 468 +** Enable/Disable control for loads using e-DMX channel value 469 +** Map DMX to ShowRunnerCLC™ loads 470 +* EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client) 471 +** Configurable IP address and IP-ID, change at runtime 472 +** Configurable rooms to export, change at runtime 473 +** Changes generate new RSD file at runtime that may be provided to the AV programmer 474 +* HTTP REST API w/ Authorization 475 +* Lightweight API provides real-time control/feedback using CoAP 476 +* TCP Interface using simple ASCII commands, subscriptions supported 477 +* UDP Receiver using simple ASCII commands 478 +* Zum Floor Hub Support for integration, Export ShowRunnerCLC™ areas to the Floor Hub (Licensed Feature) 479 +* Remote hardware support from neighbor ShowRunnerCLC™ System: 480 +** Allows a central ShowRunner system to integrate edge processors 90 90 ** AV Serial Interface 91 91 ** Loads 92 92 ** Controllers ... ... @@ -95,19 +95,9 @@ 95 95 ** Occupancy Sensor (including setup for Cresnet sensors) 96 96 ** Partition Sensors (including setup for Cresnet sensors) 97 97 ** Photocells 98 -* Web based reporting directly from the processor allows generation of as built documentation: Cresnet Discovery, Device Status, Event Schedule, Keypad Schedule, Load Schedule, and Panel Schedule 99 99 100 -=== Integrations===490 +==== Reporting ==== 101 101 102 -* AV Integration protocol via serial port 103 -* BACNET Support for integration of Areas, Loads (Licensed Feature) 104 -* Crestron Fusion (Licensed Feature) 105 -* E-DMX Receive - Receive DMX (SACN or Art-Net) and translate to ShowRunner Loads 106 -* EISC Export for AV Integration, dynamic creation from the UI (3-series or classic) 107 -* Zum Floor Hub Support for integration, Export SHOWRUNNER™ areas to the Floor Hub (Licensed Feature) 108 - 109 -=== Reporting === 110 - 111 111 ShowRunner provides a website via the processor's internal webserver with the following reports. All data is live at the time of the generation of the report. 112 112 113 113 * Area Load Schedule - Load schedule by Area